Skip to content
worldfires
ID · Indonesia · –

Merauke fire, 14 September 2026 Merauke

Out · last detection 24 Sept 2026, 03:49 UTC

The fire started on 14 September 2026 in Merauke, Indonesia, and satellites saw it burning for 11 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,843 hectares from heat detections, spread across a single municipality.

Number 256 in Indonesia in 2026, of 993.

GWIS near-real-time perimeter, from the layer that changed in October 2025: this fire is not compared with fires from earlier years, because since then the GWIS layer gives more and larger perimeters.

Burnt area
3,843ha
GWIS perimeter (Copernicus)
Duration
11days
14 Sept 2026 – 24 Sept 2026
Municipalities hit
1
regencies
Started on
14 Sept
2026
Heat detections
74
in a single hotspot: 75 MW
Danger at start
47
Very high · FWI index
Average daily power
160MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 14 Sept24 Sept
24 Sept 2026

How it evolved, day by day

15 Sept 2026 · 599 MW · 24 16 Sept 2026 · 5 MW · 1 18 Sept 2026 · 10 MW · 2 20 Sept 2026 · 212 MW · 12 21 Sept 2026 · 49 MW · 12 22 Sept 2026 · 204 MW · 19 24 Sept 2026 · 40 MW · 4
15 Sept 18 Sept 21 Sept 24 Sept

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

34°high
55km/h · peak gust
37%lowest humidity

It had gone 15 days without rain (1 mm or more) when it started.

This area had burned before

77% of the perimeter overlaps earlier fires recorded since 2016: 222 ha in 2018, 737 ha in 2019, 638 ha in 2020, 2,367 ha in 2023. Part of it burned more than once, so the yearly figures add up to more than the 2,959 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 2.4% of the area of London (38 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Merauke where it started
    4,057 ha reached on 15 Sept
    0.1 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Strong wind: 1.0 % of the area in Indonesia

Day High Min. humidity Peak gust Rain Danger (FWI)
14 Sept 31.0 °C 47 % 50 km/h 0.2 mm Very high 47
15 Sept 32.3 °C 42 % 48 km/h 0.0 mm Very high 45
16 Sept 31.4 °C 45 % 46 km/h 0.3 mm Very high 43
17 Sept 33.9 °C 37 % 48 km/h 0.0 mm Very high 45
18 Sept 32.9 °C 43 % 53 km/h 0.0 mm Very high 47
19 Sept 32.2 °C 43 % 55 km/h 0.0 mm Very high 49
20 Sept 32.1 °C 43 % 44 km/h 0.0 mm Very high 42
21 Sept 32.6 °C 44 % 35 km/h 0.0 mm High 36
22 Sept 32.0 °C 47 % 39 km/h 0.0 mm High 35
23 Sept 32.2 °C 48 % 43 km/h 0.0 mm High 36
24 Sept 32.7 °C 47 % 43 km/h 0.0 mm High 35
25 Sept after 35.1 °C 36 % 41 km/h 0.0 mm Very high 43
26 Sept after 34.9 °C 36 % 44 km/h 0.0 mm Very high 41
27 Sept after 34.8 °C 37 % 43 km/h 0.0 mm Very high 45
28 Sept after 35.1 °C 35 % 45 km/h 0.0 mm Very high 46
29 Sept after 35.5 °C 30 % 42 km/h 0.0 mm Very high 47
30 Sept after 35.6 °C 32 % 38 km/h 0.0 mm Very high 43
1 Oct after 34.2 °C 40 % 48 km/h 0.0 mm Very high 48
2 Oct after 34.0 °C 38 % 49 km/h 0.0 mm Very high 48
3 Oct after 32.5 °C 44 % 46 km/h 0.0 mm Very high 44
4 Oct after 34.6 °C 39 % 38 km/h 0.0 mm Very high 39

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 7 Sept 2026
After · 1 Oct 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 12 September 2026 the air beside the fire reached 95 µg/m³ of PM2.5. That day averaged 34: 2.3 times the WHO daily guideline (15).

PM2.5 peak95 µg/m³
Days over the guideline14 days
PM10100 µg/m³
Optical depth1.95
12 Sept16 Sept20 Sept24 Sept
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 74Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Indonesia

Frequently asked questions

How long did the Merauke fire last?
GWIS (Copernicus) dates it between 14 September 2026 and 24 September 2026: 11 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,843 hectares (38.4 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Merauke (4,057 ha, 0.1 %).
What was the weather like?
During the fire the temperature reached 33.9 °C, humidity dropped to 37 % and gusts hit 55 km/h. The fire danger index (FWI) reached 49, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Indonesia (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 112 · Emergency number and official warnings

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Area: 4,032 → 3,843 ha.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery; 2 polygons grouped in this page.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 74 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.