Skip to content
worldfires
MZ · Mozambique · →

Mecula fire, 21 September 2016 Mecula

Out · last detection 25 Sept 2016, 11:19 UTC

The fire started on 21 September 2016 in Mecula, Mozambique, and satellites saw it burning for 5 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 6,523 hectares from heat detections, spread across a single municipality.

It is the 128th largest in Niassa since 2016 (of 577 with a page). Number 49 in Mozambique in 2016, of 194.

Compare with…
Burnt area
6,523ha
GWIS perimeter (Copernicus)
Duration
5days
21 Sept 2016 – 25 Sept 2016
Municipalities hit
1
districts
Started on
21 Sept
2016
Heat detections
188
in a single hotspot: 64 MW
Danger at start
33
High · FWI index
Average daily power
364MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 21 Sept25 Sept
25 Sept 2016

How it evolved, day by day

21 Sept 2016 · 74 MW · 26 22 Sept 2016 · 275 MW · 55 23 Sept 2016 · 1,193 MW · 82 24 Sept 2016 · 76 MW · 11 25 Sept 2016 · 202 MW · 14
21 Sept 22 Sept 23 Sept 24 Sept 25 Sept

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

32°high
40km/h · peak gust
28%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started. Rain came after the fire: 6.0 mm on 4 Oct.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 4.1% of the area of London (65 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Mecula where it started
    6,570 ha reached on 21 Sept
    0.4 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2015
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2015, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
21 Sept 30.4 °C 29 % 40 km/h 0.0 mm High 33
22 Sept 31.3 °C 28 % 28 km/h 0.0 mm High 33
23 Sept 31.8 °C 30 % 32 km/h 0.0 mm High 32
24 Sept 32.3 °C 33 % 26 km/h 0.0 mm High 32
25 Sept 32.3 °C 30 % 30 km/h 0.0 mm High 35
26 Sept after 31.0 °C 32 % 36 km/h 0.0 mm High 36
27 Sept after 31.0 °C 30 % 31 km/h 0.0 mm High 35
28 Sept after 30.7 °C 39 % 37 km/h 0.1 mm High 34
29 Sept after 29.5 °C 45 % 35 km/h 0.3 mm High 30
30 Sept after 31.5 °C 41 % 32 km/h 0.3 mm High 28
1 Oct after 31.3 °C 37 % 28 km/h 0.0 mm High 30
2 Oct after 31.6 °C 34 % 32 km/h 0.0 mm High 32
3 Oct after 32.7 °C 33 % 31 km/h 0.0 mm High 33
4 Oct after 26.1 °C 52 % 37 km/h 6.0 mm Low 6

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 14 Sept 2016
After · 2 Oct 2016

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 188Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Mozambique ›

Frequently asked questions

How long did the Mecula fire last?
GWIS (Copernicus) dates it between 21 September 2016 and 25 September 2016: 5 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 6,523 hectares (65.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Mecula (6,570 ha, 0.4 %).
What was the weather like?
During the fire the temperature reached 32.3 °C, humidity dropped to 28 % and gusts hit 40 km/h. The fire danger index (FWI) reached 35, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mozambique (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 188 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2015, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.