Skip to content
worldfires
SS · South Sudan · →

Mayendit fire, January 2020 Mayendit, Tonj East

Out · last detection 28 Jan 2020, 11:49 UTC

The fire started on 27 January 2020 in Mayendit, South Sudan, and satellites saw it burning for 2 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,046 hectares from heat detections, spread across 2 municipalities.

It is the 85th largest in Unity since 2016 (of 85 with a page). Number 188 in South Sudan in 2020, of 190.

Burnt area
5,046ha
GWIS perimeter (Copernicus)
Duration
2days
27 Jan 2020 – 28 Jan 2020
Municipalities hit
2
counties
Started on
27 Jan
2020
Heat detections
119
in a single hotspot: 231 MW
Danger at start
56
Extreme · FWI index
Energy released
6.9GW
sum of detected power

Where it burned

28 Jan 2020
HOTSPOTS BY DAY 27 Jan28 Jan

How it evolved, day by day

2728

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

37°high
36km/h · peak gust
12%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

86% of the perimeter overlaps earlier fires recorded since 2016: 656 ha in 2016, 3,538 ha in 2017, 1,557 ha in 2018. Part of it burned more than once, so the yearly figures add up to more than the 4,320 ha that had burned before.

What happened to each town

  1. Mayendit where it started
    4,993 ha reached on 27 Jan
    1.6 %
  2. 84 ha reached on 27 Jan
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
27 Jan 35.7 °C 12 % 36 km/h 0.0 mm Extreme 56
28 Jan 36.7 °C 12 % 33 km/h 0.0 mm Extreme 54
29 Jan after 35.9 °C 12 % 35 km/h 0.0 mm Extreme 54
30 Jan after 36.0 °C 13 % 29 km/h 0.0 mm Extreme 55
31 Jan after 36.3 °C 12 % 33 km/h 0.0 mm Extreme 54
1 Feb after 36.0 °C 14 % 35 km/h 0.0 mm Extreme 57
2 Feb after 37.0 °C 12 % 32 km/h 0.0 mm Extreme 54
3 Feb after 37.8 °C 11 % 37 km/h 0.0 mm Extreme 57
4 Feb after 36.4 °C 11 % 36 km/h 0.0 mm Extreme 60
5 Feb after 35.8 °C 9 % 37 km/h 0.0 mm Extreme 59
6 Feb after 38.0 °C 10 % 38 km/h 0.0 mm Extreme 60
7 Feb after 38.2 °C 8 % 41 km/h 0.0 mm Extreme 62

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 20 Jan 2020
After · 4 Feb 2020

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 119Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in South Sudan ›

Frequently asked questions

How long did the Mayendit fire last?
GWIS (Copernicus) dates it between 27 January 2020 and 28 January 2020: 2 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,046 hectares (50.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Mayendit (4,993 ha, 1.6 %); Tonj East (84 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 36.7 °C, humidity dropped to 12 % and gusts hit 36 km/h. The fire danger index (FWI) reached 56, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of South Sudan (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.