Skip to content
worldfires
BJ · Benin · →

Matéri fire, 14 December 2020 Matéri

Out · last detection 17 Dec 2020, 13:57 UTC

The fire started on 14 December 2020 in Matéri, Benin, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,472 hectares from heat detections, spread across a single municipality.

It is the 171th largest in Atakora since 2016 (of 523 with a page). Number 26 in Benin in 2020, of 94.

Compare with…
Burnt area
2,472ha
GWIS perimeter (Copernicus)
Duration
4days
14 Dec 2020 – 17 Dec 2020
Municipalities hit
1
communes
Started on
14 Dec
2020
Heat detections
59
in a single hotspot: 82 MW
Danger at start
37
High · FWI index
Average daily power
123MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 14 Dec17 Dec
17 Dec 2020

How it evolved, day by day

14 Dec 2020 · 124 MW · 15 15 Dec 2020 · 267 MW · 11 16 Dec 2020 · 78 MW · 23 17 Dec 2020 · 24 MW · 10
14 Dec 15 Dec 16 Dec 17 Dec

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

38°high
31km/h · peak gust
13%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

21% of the perimeter overlaps earlier fires recorded since 2016: 526 ha in 2017.

How big is it?

10 km
It burned the equivalent of 1.6% of the area of London (25 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Matéri where it started
    2,472 ha reached on 14 Dec
    1.4 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area0.21 ha
Residents≈ 30

Inside the perimeter there were about 0.21 hectares of built-up land and about 30 residents (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
14 Dec 36.9 °C 28 % 24 km/h 0.0 mm High 37
15 Dec 37.8 °C 21 % 22 km/h 0.0 mm Very high 40
16 Dec 37.7 °C 14 % 31 km/h 0.0 mm Extreme 50
17 Dec 37.1 °C 13 % 28 km/h 0.0 mm Very high 46
18 Dec after 36.4 °C 14 % 23 km/h 0.0 mm Very high 46
19 Dec after 36.2 °C 14 % 28 km/h 0.0 mm Very high 47
20 Dec after 35.9 °C 18 % 26 km/h 0.0 mm Very high 46
21 Dec after 35.8 °C 16 % 26 km/h 0.0 mm Very high 47
22 Dec after 36.1 °C 12 % 27 km/h 0.0 mm Very high 47
23 Dec after 35.9 °C 14 % 29 km/h 0.0 mm Very high 49
24 Dec after 36.3 °C 16 % 28 km/h 0.0 mm Very high 48
25 Dec after 35.5 °C 17 % 34 km/h 0.0 mm Extreme 54
26 Dec after 34.3 °C 14 % 38 km/h 0.0 mm Extreme 57
27 Dec after 33.9 °C 16 % 34 km/h 0.0 mm Extreme 52

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 7 Dec 2020
After · 24 Dec 2020

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 59Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Benin ›

Frequently asked questions

How long did the Matéri fire last?
GWIS (Copernicus) dates it between 14 December 2020 and 17 December 2020: 4 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,472 hectares (24.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Matéri (2,472 ha, 1.4 %).
What was the weather like?
During the fire the temperature reached 37.8 °C, humidity dropped to 13 % and gusts hit 31 km/h. The fire danger index (FWI) reached 50, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Benin (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 59 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.