Skip to content
worldfires
ET · Ethiopia · –

Maokomo Special fire, 8 January 2020 Maokomo Special

Out · last detection 22 Jan 2020, 22:57 UTC

The fire started on 8 January 2020 in Maokomo Special, Ethiopia, and satellites saw it burning for 15 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,586 hectares from heat detections, spread across a single municipality.

It is the 395th largest in Beneshangul Gumu since 2016 (of 635 with a page). Number 98 in Ethiopia in 2020, of 177.

The power measured by the satellite is low (27.4 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
2,586ha
GWIS perimeter (Copernicus)
Duration
15days
8 Jan 2020 – 22 Jan 2020
Municipalities hit
1
districts
Started on
8 Jan
2020
Heat detections
65
in a single hotspot: 27 MW
Danger at start
27
High · FWI index
Average daily power
24MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 8 Jan22 Jan
22 Jan 2020

How it evolved, day by day

8 Jan 2020 · 20 MW · 3 9 Jan 2020 · 86 MW · 13 10 Jan 2020 · 10 MW · 6 11 Jan 2020 · 16 MW · 10 12 Jan 2020 · 97 MW · 12 13 Jan 2020 · 2 MW · 1 14 Jan 2020 · 29 MW · 9 15 Jan 2020 · 15 MW · 2 18 Jan 2020 · 3 MW · 4 19 Jan 2020 · 1 MW · 2 20 Jan 2020 · 1 MW · 1 22 Jan 2020 · 3 MW · 2
8 Jan 12 Jan 19 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

30°high
40km/h · peak gust
20%lowest humidity

It had gone 42 days without rain (1 mm or more) when it started.

This area had burned before

52% of the perimeter overlaps earlier fires recorded since 2016: 874 ha in 2016, 581 ha in 2017, 128 ha in 2018, 295 ha in 2019. Part of it burned more than once, so the yearly figures add up to more than the 1,351 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.6% of the area of London (26 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Maokomo Special where it started
    2,604 ha reached on 8 Jan
    0.9 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
8 Jan 29.5 °C 33 % 30 km/h 0.0 mm High 27
9 Jan 28.6 °C 28 % 31 km/h 0.0 mm High 28
10 Jan 28.9 °C 26 % 37 km/h 0.0 mm High 35
11 Jan 28.0 °C 20 % 33 km/h 0.0 mm High 35
12 Jan 27.4 °C 21 % 33 km/h 0.0 mm High 35
13 Jan 27.3 °C 26 % 33 km/h 0.0 mm High 36
14 Jan 29.7 °C 23 % 31 km/h 0.0 mm High 33
15 Jan 30.1 °C 20 % 31 km/h 0.0 mm Very high 42
16 Jan 29.7 °C 23 % 27 km/h 0.0 mm Very high 43
17 Jan 29.7 °C 23 % 31 km/h 0.0 mm Very high 39
18 Jan 30.2 °C 25 % 35 km/h 0.0 mm Very high 48
19 Jan 29.8 °C 27 % 34 km/h 0.0 mm Very high 39
20 Jan 29.6 °C 29 % 36 km/h 0.0 mm High 36
21 Jan 28.7 °C 29 % 40 km/h 0.0 mm High 37
22 Jan 27.7 °C 29 % 33 km/h 0.0 mm High 34
23 Jan after 27.2 °C 29 % 34 km/h 0.0 mm High 33
24 Jan after 28.5 °C 28 % 34 km/h 0.0 mm High 30
25 Jan after 29.5 °C 26 % 36 km/h 0.0 mm High 35
26 Jan after 29.8 °C 19 % 35 km/h 0.0 mm Very high 42
27 Jan after 29.0 °C 23 % 34 km/h 0.0 mm Very high 38
28 Jan after 29.7 °C 26 % 31 km/h 0.0 mm Very high 40
29 Jan after 29.1 °C 22 % 30 km/h 0.0 mm High 35
30 Jan after 29.2 °C 25 % 32 km/h 0.0 mm High 38
31 Jan after 28.4 °C 25 % 31 km/h 0.0 mm High 37
1 Feb after 28.3 °C 27 % 33 km/h 0.0 mm High 38

Its twins: fires that started in the same weather

It started with an FWI of 27.4, a minimum humidity of 33% and 42 days without rain. Fires in the area that started in weather like this since 2016: 44.

FWI at the start 27.4
Minimum humidity 33 %
Days without rain 42
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Bure fire, January 2021
2,627 ha 5 days FWI 29.1 Min. humidity 32 % 151 km away, in 2021

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

9 days
median duration
3,084 ha
median area
100 %
went past 1,000 ha
1.9 mm
rain at the end (median; 10 of 44 had it)

It burned an area similar to its twins (2,586 ha against a median of 3,084 ha) and lasted 15 days, against 9 days.

In 34 of 44, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.9 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
40km/h · max. gust

It was considered over on 22 Jan, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 10 of 44, with a median of 1.9 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 1 Jan 2020
After · 29 Jan 2020

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 65Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ethiopia

Frequently asked questions

How long did the Maokomo Special fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 8 January 2020 to 22 January 2020 (15 days). The perimeter dates it from 8 January 2020 to 15 January 2020.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,586 hectares (25.9 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Maokomo Special (2,604 ha, 0.9 %).
What was the weather like?
During the fire the temperature reached 30.2 °C, humidity dropped to 20 % and gusts hit 40 km/h. The fire danger index (FWI) reached 48, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ethiopia (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 44. Their median duration was 9 days and their median area 3,084 ha; 100 % went past 1,000 ha. In 34 of 44, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.9 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 15 January 2020 → 22 January 2020.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 8 January 2020 to 15 January 2020. 65 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.