Mamouroudou fire, 12 February 2024 Mamouroudou

Out · last detection 18 Feb 2024, 13:45 UTC

The fire started on 12 February 2024 in Mamouroudou, Guinea, and satellites saw it burning for 7 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,168 hectares from heat detections, spread across a single municipality.

It is the 249th largest in Kankan since 2016 (of 308 with a page). Number 92 in Guinea in 2024, of 118.

Burnt area
2,168ha
GWIS perimeter (Copernicus)
Duration
7days
12 Feb 2024 – 18 Feb 2024
Municipalities hit
1
sub-prefectures
Started on
12 Feb
2024
Heat detections
85
in a single hotspot: 51 MW
Danger at start
40
Very high · FWI index
Average daily power
275MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 12 Feb18 Feb
18 Feb 2024

How it evolved, day by day

12 Feb 2024 · 6 MW · 1 13 Feb 2024 · 9 MW · 2 14 Feb 2024 · 1,147 MW · 73 15 Feb 2024 · 7 MW · 2 18 Feb 2024 · 206 MW · 7
12 Feb 13 Feb 14 Feb 15 Feb 18 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

39°high
28km/h · peak gust
13%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

93% of the perimeter overlaps earlier fires recorded since 2016: 646 ha in 2016, 702 ha in 2017, 1,322 ha in 2018, 320 ha in 2019, 629 ha in 2020, 1,677 ha in 2021, 98 ha in 2022, 981 ha in 2023. Part of it burned more than once, so the yearly figures add up to more than the 2,021 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.4% of the area of London (22 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Mamouroudou where it started
    2,182 ha reached on 12 Feb
    1.4 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with 60 days without rain: 34 % of the area in Guinea

Day High Min. humidity Peak gust Rain Danger (FWI)
12 Feb 38.1 °C 21 % 21 km/h 0.0 mm Very high 40
13 Feb 38.6 °C 18 % 26 km/h 0.0 mm High 38
14 Feb 39.2 °C 13 % 28 km/h 0.0 mm Very high 41
15 Feb 39.1 °C 13 % 25 km/h 0.0 mm Very high 44
16 Feb 37.6 °C 18 % 27 km/h 0.0 mm Very high 42
17 Feb 37.3 °C 18 % 22 km/h 0.0 mm Very high 41
18 Feb 38.2 °C 18 % 22 km/h 0.0 mm Very high 39
19 Feb after 38.2 °C 17 % 24 km/h 0.0 mm Very high 45
20 Feb after 37.1 °C 10 % 34 km/h 0.0 mm Extreme 68
21 Feb after 36.7 °C 10 % 22 km/h 0.0 mm Extreme 55
22 Feb after 35.5 °C 12 % 28 km/h 0.0 mm Extreme 60
23 Feb after 34.3 °C 11 % 28 km/h 0.0 mm Extreme 61
24 Feb after 36.9 °C 11 % 26 km/h 0.0 mm Extreme 61
25 Feb after 37.9 °C 6 % 28 km/h 0.0 mm Extreme 60
26 Feb after 37.9 °C 17 % 26 km/h 0.0 mm Very high 48
27 Feb after 38.2 °C 21 % 30 km/h 0.0 mm Very high 42
28 Feb after 38.2 °C 21 % 32 km/h 0.0 mm Very high 44

Its twins: fires that started in the same weather

It started with an FWI of 39.5, a minimum humidity of 21% and more than two months without rain. Fires in the area that started in weather like this since 2016: 48.

FWI at the start 39.5
Minimum humidity 21 %
Days without rain 60+
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Tinti Oulen fire, February 2019
2,470 ha 12 days FWI 39.6 Min. humidity 21 % 64 km away, in 2019

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

11 days
median duration
2,440 ha
median area
100 %
went past 1,000 ha
2.7 mm
rain at the end (median; 32 of 48 had it)

It burned an area similar to its twins (2,168 ha against a median of 2,440 ha) and lasted 7 days, against 11 days.

In 16 of 48, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.7 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
28km/h · max. gust

It was considered over on 18 Feb, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 32 of 48, with a median of 2.7 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 5 Feb 2024
After · 25 Feb 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 10 February 2024 the air beside the fire reached 70 µg/m³ of PM2.5. That day averaged 52: 3.5 times the WHO daily guideline (15).

PM2.5 peak70 µg/m³
Days over the guideline8 days
PM10152 µg/m³
Optical depth0.71
10 Feb12 Feb14 Feb16 Feb
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 85Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Guinea

Frequently asked questions

How long did the Mamouroudou fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 12 February 2024 to 18 February 2024 (7 days). The perimeter dates it from 12 February 2024 to 14 February 2024.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,168 hectares (21.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Mamouroudou (2,182 ha, 1.4 %).
What was the weather like?
During the fire the temperature reached 39.2 °C, humidity dropped to 13 % and gusts hit 28 km/h. The fire danger index (FWI) reached 44, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Guinea (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 48. Their median duration was 11 days and their median area 2,440 ha; 100 % went past 1,000 ha. In 16 of 48, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.7 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 14 February 2024 → 18 February 2024.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 12 February 2024 to 14 February 2024. 85 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.