Skip to content
worldfires
SS · South Sudan · →

Magwi fire, November 2025 Juba, Magwi, Torit

Out · last detection 9 Dec 2025, 10:51 UTC

The fire started on 30 November 2025 in Magwi, South Sudan, and satellites saw it burning for 10 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,540 hectares from heat detections, spread across 3 municipalities.

It is the 63th largest in Eastern Equatoria since 2016 (of 80 with a page). Number 246 in South Sudan in 2025, of 292.

Compare with…
Burnt area
5,540ha
GWIS perimeter (Copernicus)
Duration
10days
30 Nov 2025 – 9 Dec 2025
Municipalities hit
3
counties
Started on
30 Nov
2025
Heat detections
164
in a single hotspot: 110 MW
Danger at start
18
Moderate · FWI index
Average daily power
244MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 30 Nov9 Dec
9 Dec 2025

How it evolved, day by day

30 Nov 2025 · 2 MW · 1 1 Dec 2025 · 75 MW · 10 2 Dec 2025 · 516 MW · 53 3 Dec 2025 · 33 MW · 4 4 Dec 2025 · 920 MW · 24 6 Dec 2025 · 44 MW · 4 7 Dec 2025 · 24 MW · 6 8 Dec 2025 · 152 MW · 15 9 Dec 2025 · 432 MW · 11
30 Nov 2 Dec 4 Dec 7 Dec 9 Dec

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
26km/h · peak gust
16%lowest humidity

It had gone 20 days without rain (1 mm or more) when it started. Rain came after the fire: 1.5 mm on 17 Dec.

This area had burned before

71% of the perimeter overlaps earlier fires recorded since 2016: 672 ha in 2016, 2,270 ha in 2017, 9 ha in 2018, 651 ha in 2020, 1,514 ha in 2021, 249 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 3,925 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 3.5% of the area of London (55 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. 4,118 ha reached on 25 Nov
    0.2 %
  2. Magwi where it started
    1,264 ha reached on 24 Nov
    0.2 %
  3. 193 ha reached on 1 Dec
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area0.14 ha
Residents< 20

Inside the perimeter there were about 0.14 hectares of built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
30 Nov 35.1 °C 27 % 22 km/h 0.0 mm Moderate 18
1 Dec 35.2 °C 22 % 25 km/h 0.0 mm High 21
2 Dec 35.7 °C 16 % 20 km/h 0.0 mm High 25
3 Dec 34.8 °C 20 % 18 km/h 0.0 mm High 25
4 Dec 35.0 °C 27 % 22 km/h 0.0 mm High 24
5 Dec 34.5 °C 29 % 18 km/h 0.0 mm High 22
6 Dec 34.9 °C 29 % 26 km/h 0.0 mm High 23
7 Dec 34.9 °C 31 % 26 km/h 0.0 mm High 24
8 Dec 34.7 °C 28 % 23 km/h 0.0 mm High 24
9 Dec 35.5 °C 26 % 24 km/h 0.0 mm High 24
10 Dec after 32.0 °C 36 % 27 km/h 0.0 mm Moderate 20
11 Dec after 32.8 °C 34 % 35 km/h 0.1 mm High 25
12 Dec after 30.6 °C 40 % 38 km/h 0.0 mm High 23
13 Dec after 28.9 °C 40 % 30 km/h 0.4 mm Moderate 20
14 Dec after 31.9 °C 34 % 25 km/h 0.0 mm Moderate 19
15 Dec after 33.5 °C 37 % 28 km/h 0.1 mm High 22
16 Dec after 32.2 °C 34 % 34 km/h 0.0 mm High 22
17 Dec after 31.6 °C 31 % 27 km/h 1.5 mm Moderate 15

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 23 Nov 2025
After · 16 Dec 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 3 December 2025 the air beside the fire reached 57 µg/m³ of PM2.5. That day averaged 39: 2.6 times the WHO daily guideline (15).

PM2.5 peak57 µg/m³
Days over the guideline10 days
PM1059 µg/m³
Optical depth0.72
282930123456789101112
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 164Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in South Sudan ›

Frequently asked questions

How long did the Magwi fire last?
GWIS (Copernicus) dates it between 30 November 2025 and 9 December 2025: 10 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,540 hectares (55.4 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 3 municipalities: Juba (4,118 ha, 0.2 %); Magwi (1,264 ha, 0.2 %); Torit (193 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 35.7 °C, humidity dropped to 16 % and gusts hit 26 km/h. The fire danger index (FWI) reached 25, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of South Sudan (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 164 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.