Loudima fire, 1 September 2026 Loudima, Sibiti

Out · last detection 1 Sept 2026, 23:52 UTC

The fire started on 1 September 2026 in Loudima, Republic of the Congo, and satellites saw it burning for 2 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,164 hectares from heat detections, spread across 2 municipalities.

It is the 128th largest in Bouenza since 2016 (of 181 with a page). Number 248 in Republic of the Congo in 2026, of 360.

Compare with…
Burnt area
1,164ha
GWIS perimeter (Copernicus)
Duration
2days
1 Sept 2026 – 2 Sept 2026
Municipalities hit
2
districts
Started on
1 Sept
2026
Heat detections
14
in a single hotspot: 46 MW
Danger at start
21
Moderate · FWI index
Average daily power
161MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 1 Sept2 Sept

How it evolved, day by day

1 Sept 2026 · 161 MW · 14

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

34°high
24km/h · peak gust
48%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 0.7% of the area of London (12 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Loudima where it started
    835 ha reached on 1 Sept
    0.3 %
  2. 336 ha reached on 1 Sept
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
1 Sept 33.8 °C 48 % 24 km/h 0.0 mm Moderate 21
2 Sept 29.8 °C 60 % 24 km/h 0.0 mm Moderate 18
3 Sept after 28.6 °C 66 % 24 km/h 0.2 mm Moderate 16
4 Sept after 33.2 °C 50 % 26 km/h 0.0 mm Moderate 20
5 Sept after 29.1 °C 63 % 27 km/h 0.0 mm Moderate 19
6 Sept after 30.2 °C 59 % 20 km/h 0.0 mm Moderate 18
7 Sept after 34.8 °C 47 % 28 km/h 0.2 mm High 23
8 Sept after 30.1 °C 60 % 23 km/h 0.0 mm Moderate 20
9 Sept after 28.2 °C 61 % 24 km/h 0.0 mm Moderate 18
10 Sept after 32.2 °C 49 % 28 km/h 0.0 mm High 22
11 Sept after 30.0 °C 59 % 28 km/h 0.0 mm Moderate 20
12 Sept after 31.5 °C 55 % 24 km/h 0.0 mm Moderate 20

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 25 Aug 2026
After · 9 Sept 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 2 September 2026 the air beside the fire reached 64 µg/m³ of PM2.5. That day averaged 39: 2.6 times the WHO daily guideline (15).

PM2.5 peak64 µg/m³
Days over the guideline6 days
PM1067 µg/m³
Optical depth2.02
30 Aug1 Sept3 Sept5 Sept
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 14Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Republic of the Congo

Frequently asked questions

How long did the Loudima fire last?
GWIS (Copernicus) dates it between 1 September 2026 and 2 September 2026: 2 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,164 hectares (11.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Loudima (835 ha, 0.3 %); Sibiti (336 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 33.8 °C, humidity dropped to 48 % and gusts hit 24 km/h. The fire danger index (FWI) reached 21, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Republic of the Congo (geoBoundaries ADM2). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 14 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Map Library 2007, nombres de Wikidata) (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.