Skip to content
worldfires
CM · Cameroon · –

Logone-Birni fire, 13 March 2025 Logone-Birni

Out · last detection 19 Mar 2025, 11:58 UTC

The fire started on 13 March 2025 in Logone-Birni, Cameroon, and satellites saw it burning for 7 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,449 hectares from heat detections, spread across a single municipality.

It is the 89th largest in Far North since 2016 (of 260 with a page). Number 77 in Cameroon in 2025, of 160.

The power measured by the satellite is low (22.4 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
1,449ha
GWIS perimeter (Copernicus)
Duration
7days
13 Mar 2025 – 19 Mar 2025
Municipalities hit
1
communes
Started on
13 Mar
2025
Heat detections
34
in a single hotspot: 22 MW
Danger at start
72
Very extreme · FWI index
Average daily power
73MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 13 Mar19 Mar
19 Mar 2025

How it evolved, day by day

14 Mar 2025 · 35 MW · 2 16 Mar 2025 · 23 MW · 4 17 Mar 2025 · 145 MW · 12 18 Mar 2025 · 141 MW · 12 19 Mar 2025 · 23 MW · 4
14 Mar 16 Mar 17 Mar 18 Mar 19 Mar

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

42°high
44km/h · peak gust
4%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

10% of the perimeter overlaps earlier fires recorded since 2016: 134 ha in 2016, 74 ha in 2021. Part of it burned more than once, so the yearly figures add up to more than the 141 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 0.9% of the area of London (14 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Logone-Birni where it started
    1,458 ha reached on 14 Mar
    0.5 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area0.23 ha
Residents≈ 40

Inside the perimeter there were about 0.23 hectares of built-up land and about 40 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with Very dry air: 32 % of the area in Cameroon 60 days without rain: 51 % of the area in Cameroon

Day High Min. humidity Peak gust Rain Danger (FWI)
13 Mar 41.8 °C 4 % 40 km/h 0.0 mm Very extreme 72
14 Mar 41.9 °C 5 % 36 km/h 0.0 mm Extreme 68
15 Mar 41.7 °C 7 % 44 km/h 0.0 mm Very extreme 74
16 Mar 41.5 °C 6 % 43 km/h 0.0 mm Very extreme 75
17 Mar 41.6 °C 4 % 38 km/h 0.0 mm Very extreme 71
18 Mar 41.2 °C 4 % 32 km/h 0.0 mm Extreme 67
19 Mar 42.1 °C 5 % 30 km/h 0.0 mm Extreme 64
20 Mar after 43.1 °C 6 % 45 km/h 0.0 mm Very extreme 80
21 Mar after 42.2 °C 7 % 54 km/h 0.0 mm Very extreme 94
22 Mar after 40.4 °C 9 % 52 km/h 0.0 mm Very extreme 85
23 Mar after 38.1 °C 7 % 40 km/h 0.0 mm Very extreme 72
24 Mar after 40.5 °C 7 % 35 km/h 0.0 mm Extreme 68
25 Mar after 40.8 °C 7 % 34 km/h 0.0 mm Extreme 66
26 Mar after 42.7 °C 8 % 27 km/h 0.0 mm Extreme 66
27 Mar after 42.5 °C 6 % 30 km/h 0.0 mm Extreme 66
28 Mar after 42.3 °C 4 % 34 km/h 0.0 mm Extreme 66
29 Mar after 42.1 °C 3 % 31 km/h 0.0 mm Extreme 64

Its twins: fires that started in the same weather

It started with an FWI of 71.6, a minimum humidity of 4% and more than two months without rain. Fires in the area that started in weather like this since 2016: 39.

FWI at the start 71.6
Minimum humidity 4 %
Days without rain 60+
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Logone-Birni fire, May 2024
1,545 ha 2 days FWI 72.5 Min. humidity 5 % 19 km away, in 2024

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

5 days
median duration
1,480 ha
median area
100 %
went past 1,000 ha
1.3 mm
rain at the end (median; 4 of 39 had it)

It burned an area similar to its twins (1,449 ha against a median of 1,480 ha) and lasted 7 days, against 5 days.

In 35 of 39, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.3 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
44km/h · max. gust

It was considered over on 19 Mar, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 4 of 39, with a median of 1.3 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 6 Mar 2025
After · 26 Mar 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 22 March 2025 the air beside the fire reached 54 µg/m³ of PM2.5. That day averaged 38: 2.6 times the WHO daily guideline (15).

PM2.5 peak54 µg/m³
Days over the guideline11 days
PM10283 µg/m³
Optical depth0.52
12 Mar15 Mar18 Mar21 Mar
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 34Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Cameroon

Frequently asked questions

How long did the Logone-Birni fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 13 March 2025 to 19 March 2025 (7 days). The perimeter dates it from 14 March 2025 to 19 March 2025.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,449 hectares (14.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Logone-Birni (1,458 ha, 0.5 %).
What was the weather like?
During the fire the temperature reached 42.1 °C, humidity dropped to 4 % and gusts hit 44 km/h. The fire danger index (FWI) reached 75, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Cameroon (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 39. Their median duration was 5 days and their median area 1,480 ha; 100 % went past 1,000 ha. In 35 of 39, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.3 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Start date: 14 March 2025 → 13 March 2025.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 14 March 2025 to 19 March 2025. 34 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.