Skip to content
worldfires
GN · Guinea · →

Lisso fire, 14 April 2016 Lisso, Kolia

Out · last detection 19 Apr 2016, 14:30 UTC

The fire started on 14 April 2016 in Lisso, Guinea, and satellites saw it burning for 6 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 4,063 hectares from heat detections, spread across 2 municipalities.

It is the 32th largest in Boké since 2016 (of 237 with a page). Number 32 in Guinea in 2016, of 172.

Burnt area
4,063ha
GWIS perimeter (Copernicus)
Duration
6days
14 Apr 2016 – 19 Apr 2016
Municipalities hit
2
sub-prefectures
Started on
14 Apr
2016
Heat detections
175
in a single hotspot: 331 MW
Danger at start
48
Very high · FWI index
Energy released
6.5GW
sum of detected power

Where it burned

19 Apr 2016
HOTSPOTS BY DAY 14 Apr19 Apr

How it evolved, day by day

1416171819

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

39°high
51km/h · peak gust
29%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started. Rain came after the fire: 1.1 mm on 20 Apr.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

What happened to each town

  1. Lisso where it started
    3,824 ha reached on 14 Apr
    4.5 %
  2. 267 ha reached on 16 Apr
    0.2 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
14 Apr 39.2 °C 29 % 51 km/h 0.0 mm Very high 48
15 Apr 36.1 °C 41 % 33 km/h 0.0 mm High 36
16 Apr 36.4 °C 41 % 35 km/h 0.0 mm High 36
17 Apr 37.8 °C 35 % 36 km/h 0.0 mm High 37
18 Apr 36.5 °C 43 % 31 km/h 0.8 mm High 26
19 Apr 36.4 °C 44 % 27 km/h 1.2 mm Moderate 20
20 Apr after 37.2 °C 41 % 29 km/h 1.1 mm High 23

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 7 Apr 2016
After · 26 Apr 2016

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 175Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Guinea ›

Frequently asked questions

How long did the Lisso fire last?
GWIS (Copernicus) dates it between 14 April 2016 and 19 April 2016: 6 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 4,063 hectares (40.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Lisso (3,824 ha, 4.5 %); Kolia (267 ha, 0.2 %).
What was the weather like?
During the fire the temperature reached 39.2 °C, humidity dropped to 29 % and gusts hit 51 km/h. The fire danger index (FWI) reached 48, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Guinea (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.