Skip to content
worldfires
ML · Mali · →

Léré fire, 25 December 2025 Léré

Out · last detection 28 Dec 2025, 13:20 UTC

The fire started on 25 December 2025 in Léré, Mali, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,069 hectares from heat detections, spread across a single municipality.

It is the 23th largest in Tombouctou since 2016 (of 45 with a page). Number 128 in Mali in 2025, of 282.

The power measured by the satellite is low (21.9 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
3,069ha
GWIS perimeter (Copernicus)
Duration
4days
25 Dec 2025 – 28 Dec 2025
Municipalities hit
1
communes
Started on
25 Dec
2025
Heat detections
28
in a single hotspot: 22 MW
Danger at start
46
Very high · FWI index
Energy released
119MW
sum of detected power

Where it burned

28 Dec 2025
HOTSPOTS BY DAY 25 Dec28 Dec

How it evolved, day by day

252628

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

31°high
36km/h · peak gust
12%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

What happened to each town

  1. Léré where it started
    3,086 ha reached on 25 Dec
    2.3 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
25 Dec 31.1 °C 12 % 23 km/h 0.0 mm Very high 46
26 Dec 28.7 °C 16 % 33 km/h 0.0 mm Extreme 50
27 Dec 30.2 °C 16 % 36 km/h 0.0 mm Extreme 53
28 Dec 28.4 °C 19 % 31 km/h 0.0 mm Very high 48
29 Dec after 31.5 °C 12 % 32 km/h 0.0 mm Very high 49
30 Dec after 31.7 °C 13 % 29 km/h 0.0 mm Very high 49
31 Dec after 32.4 °C 12 % 33 km/h 0.0 mm Extreme 52
1 Jan after 32.4 °C 13 % 36 km/h 0.0 mm Extreme 54
2 Jan after 33.4 °C 16 % 27 km/h 0.0 mm Very high 48
3 Jan after 34.5 °C 14 % 25 km/h 0.0 mm Very high 46
4 Jan after 36.2 °C 12 % 24 km/h 0.0 mm Very high 48
5 Jan after 35.7 °C 14 % 27 km/h 0.0 mm Extreme 55
6 Jan after 32.3 °C 18 % 37 km/h 0.0 mm Extreme 58
7 Jan after 27.3 °C 28 % 41 km/h 0.0 mm Extreme 52

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 18 Dec 2025
After · 4 Jan 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 28 December 2025 the air beside the fire reached 20 µg/m³ of PM2.5. That day averaged 16: 1.1 times the WHO daily guideline (15).

PM2.5 peak20 µg/m³
Days over the guideline1 day
PM1091 µg/m³
Optical depth0.17
232425262728293031
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 28Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Mali ›

Frequently asked questions

How long did the Léré fire last?
GWIS (Copernicus) dates it between 25 December 2025 and 28 December 2025: 4 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,069 hectares (30.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Léré (3,086 ha, 2.3 %).
What was the weather like?
During the fire the temperature reached 31.1 °C, humidity dropped to 12 % and gusts hit 36 km/h. The fire danger index (FWI) reached 53, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mali (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 4.0 International (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.