Skip to content
worldfires
SS · South Sudan · →

Lafon fire, 1 January 2024 Lafon

Out · last detection 8 Jan 2024, 11:31 UTC

The fire started on 1 January 2024 in Lafon, South Sudan, and satellites saw it burning for 8 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 12,961 hectares from heat detections, spread across a single municipality.

It is the 15th largest in Eastern Equatoria since 2016 (of 80 with a page). Number 37 in South Sudan in 2024, of 180.

Burnt area
12,961ha
GWIS perimeter (Copernicus)
Duration
8days
1 Jan 2024 – 8 Jan 2024
Municipalities hit
1
counties
Started on
1 Jan
2024
Heat detections
412
in a single hotspot: 82 MW
Danger at start
40
Very high · FWI index
Energy released
3.1GW
sum of detected power

Where it burned

8 Jan 2024
HOTSPOTS BY DAY 1 Jan8 Jan

How it evolved, day by day

12345678

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

39°high
30km/h · peak gust
10%lowest humidity

It had gone 42 days without rain (1 mm or more) when it started.

This area had burned before

86% of the perimeter overlaps earlier fires recorded since 2016: 2,602 ha in 2016, 1,114 ha in 2017, 5,819 ha in 2018, 1,683 ha in 2020, 7,492 ha in 2021, 3,362 ha in 2022, 764 ha in 2023. Part of it burned more than once, so the yearly figures add up to more than the 11,202 ha that had burned before.

What happened to each town

  1. Lafon where it started
    13,044 ha reached on 1 Jan
    0.8 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
1 Jan 36.9 °C 23 % 26 km/h 0.0 mm Very high 40
2 Jan 38.2 °C 22 % 30 km/h 0.0 mm Very high 42
3 Jan 38.9 °C 13 % 30 km/h 0.0 mm Very high 43
4 Jan 38.3 °C 10 % 27 km/h 0.0 mm Very high 45
5 Jan 36.9 °C 14 % 24 km/h 0.0 mm Very high 45
6 Jan 38.1 °C 12 % 28 km/h 0.0 mm Very high 46
7 Jan 36.9 °C 14 % 24 km/h 0.0 mm Very high 45
8 Jan 38.4 °C 14 % 30 km/h 0.0 mm Very high 48
9 Jan after 38.2 °C 19 % 27 km/h 0.0 mm Very high 45
10 Jan after 37.8 °C 18 % 27 km/h 0.0 mm Very high 46
11 Jan after 38.8 °C 15 % 26 km/h 0.0 mm Very high 47
12 Jan after 37.9 °C 14 % 30 km/h 0.0 mm Very high 49
13 Jan after 37.3 °C 17 % 23 km/h 0.0 mm Very high 45
14 Jan after 38.9 °C 14 % 27 km/h 0.0 mm Very high 47
15 Jan after 37.9 °C 15 % 31 km/h 0.0 mm Extreme 50
16 Jan after 36.8 °C 12 % 28 km/h 0.0 mm Very high 49
17 Jan after 36.0 °C 15 % 27 km/h 0.0 mm Very high 47
18 Jan after 35.2 °C 18 % 24 km/h 0.0 mm Very high 45

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 25 Dec 2023
After · 15 Jan 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 412Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in South Sudan ›

Frequently asked questions

How long did the Lafon fire last?
GWIS (Copernicus) dates it between 1 January 2024 and 8 January 2024: 8 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 12,961 hectares (129.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Lafon (13,044 ha, 0.8 %).
What was the weather like?
During the fire the temperature reached 38.9 °C, humidity dropped to 10 % and gusts hit 30 km/h. The fire danger index (FWI) reached 48, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of South Sudan (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.