Skip to content
worldfires
LA · Laos · →

La fire, 1 May 2017 La

Out · last detection 4 May 2017, 07:20 UTC

The fire started on 1 May 2017 in La, Laos, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,057 hectares from heat detections, spread across a single municipality.

It is the 123th largest in Oudomxay since 2016 (of 241 with a page). Number 46 in Laos in 2017, of 114.

Burnt area
3,057ha
GWIS perimeter (Copernicus)
Duration
4days
1 May 2017 – 4 May 2017
Municipalities hit
1
districts
Started on
1 May
2017
Heat detections
87
in a single hotspot: 59 MW
Danger at start
11
Low · FWI index
Energy released
1.4GW
sum of detected power

Where it burned

4 May 2017
HOTSPOTS BY DAY 1 May4 May

How it evolved, day by day

1234

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

33°high
37km/h · peak gust
27%lowest humidity

It had gone one day without rain (1 mm or more) when it started. Rain came after the fire: 8.5 mm on 5 May.

This area had burned before

31% of the perimeter overlaps earlier fires recorded since 2016: 961 ha in 2016.

What happened to each town

  1. La where it started
    3,072 ha reached on 1 May
    2.5 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
1 May 31.9 °C 33 % 37 km/h 0.1 mm Low 11
2 May 32.2 °C 32 % 34 km/h 0.0 mm Moderate 13
3 May 32.0 °C 34 % 36 km/h 0.0 mm Moderate 14
4 May 33.2 °C 27 % 22 km/h 0.0 mm Moderate 15
5 May after 28.6 °C 53 % 36 km/h 8.5 mm Very low 1

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 24 Apr 2017
After · 11 May 2017

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 87Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Laos ›

Frequently asked questions

How long did the La fire last?
GWIS (Copernicus) dates it between 1 May 2017 and 4 May 2017: 4 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,057 hectares (30.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered La (3,072 ha, 2.5 %).
What was the weather like?
During the fire the temperature reached 33.2 °C, humidity dropped to 27 % and gusts hit 37 km/h. The fire danger index (FWI) reached 15, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Laos (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.