Skip to content
worldfires
ID · Indonesia · –

Kupang fire, 14 August 2026 Kupang

Out · last detection 25 Aug 2026, 04:53 UTC

The fire started on 14 August 2026 in Kupang, Indonesia, and satellites saw it burning for 12 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,913 hectares from heat detections, spread across a single municipality.

Number 371 in Indonesia in 2026, of 967.

GWIS near-real-time perimeter, from the layer that changed in October 2025: this fire is not compared with fires from earlier years, because since then the GWIS layer gives more and larger perimeters.

Compare with…
Burnt area
2,913ha
GWIS perimeter (Copernicus)
Duration
12days
14 Aug 2026 – 25 Aug 2026
Municipalities hit
1
regencies
Started on
14 Aug
2026
Heat detections
54
in a single hotspot: 36 MW
Danger at start
28
High · FWI index
Average daily power
39MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 14 Aug25 Aug
25 Aug 2026

How it evolved, day by day

14 Aug 2026 · 7 MW · 2 15 Aug 2026 · 4 MW · 1 18 Aug 2026 · 29 MW · 6 19 Aug 2026 · 91 MW · 13 20 Aug 2026 · 7 MW · 2 21 Aug 2026 · 2 MW · 1 22 Aug 2026 · 71 MW · 12 23 Aug 2026 · 132 MW · 14 25 Aug 2026 · 8 MW · 3
14 Aug 18 Aug 20 Aug 23 Aug

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

34°high
58km/h · peak gust
26%lowest humidity

It had gone 36 days without rain (1 mm or more) when it started.

This area had burned before

74% of the perimeter overlaps earlier fires recorded since 2016: 757 ha in 2017, 6 ha in 2018, 158 ha in 2021, 1,082 ha in 2023, 556 ha in 2024, 1,400 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 2,164 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.8% of the area of London (29 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Kupang where it started
    2,933 ha reached on 14 Aug
    0.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
14 Aug 31.8 °C 39 % 35 km/h 0.0 mm High 28
15 Aug 31.4 °C 40 % 36 km/h 0.0 mm High 29
16 Aug 30.9 °C 41 % 32 km/h 0.0 mm High 29
17 Aug 30.0 °C 45 % 31 km/h 0.0 mm High 27
18 Aug 32.3 °C 28 % 27 km/h 0.0 mm High 29
19 Aug 31.9 °C 30 % 36 km/h 0.0 mm High 35
20 Aug 30.6 °C 37 % 31 km/h 0.0 mm High 32
21 Aug 31.1 °C 37 % 30 km/h 0.0 mm High 32
22 Aug 33.2 °C 26 % 42 km/h 0.0 mm Very high 40
23 Aug 30.8 °C 41 % 33 km/h 0.0 mm High 32
24 Aug 31.0 °C 40 % 35 km/h 0.0 mm High 33
25 Aug 32.3 °C 33 % 49 km/h 0.0 mm Very high 39
26 Aug after 31.6 °C 34 % 32 km/h 0.0 mm High 32
27 Aug after 31.1 °C 36 % 38 km/h 0.0 mm High 32
28 Aug after 32.3 °C 34 % 33 km/h 0.0 mm High 33
29 Aug after 33.0 °C 31 % 32 km/h 0.0 mm High 34
30 Aug after 34.0 °C 26 % 35 km/h 0.0 mm Very high 38
31 Aug after 32.5 °C 32 % 58 km/h 0.0 mm Very high 50
1 Sept after 32.8 °C 31 % 58 km/h 0.0 mm Extreme 50
2 Sept after 32.5 °C 24 % 33 km/h 0.0 mm Very high 38
3 Sept after 32.8 °C 27 % 38 km/h 0.0 mm Very high 42
4 Sept after 31.0 °C 40 % 39 km/h 0.0 mm High 37
5 Sept after 31.0 °C 40 % 38 km/h 0.0 mm High 35
6 Sept after 31.0 °C 48 % 37 km/h 0.5 mm High 31
7 Sept after 32.2 °C 42 % 37 km/h 0.0 mm High 30
8 Sept after 31.0 °C 47 % 28 km/h 0.0 mm High 27
9 Sept after 32.3 °C 38 % 50 km/h 0.0 mm High 37
10 Sept after 33.2 °C 36 % 28 km/h 0.0 mm High 28
11 Sept after 35.5 °C 25 % 26 km/h 0.0 mm High 36

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 7 Aug 2026
After · 1 Sept 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 22 August 2026 the air beside the fire reached 25 µg/m³ of PM2.5, but no daily average passed the WHO guideline (15).

PM2.5 peak25 µg/m³
Days over the guideline0 days
PM1027 µg/m³
Optical depth0.27
13 Aug17 Aug21 Aug25 Aug
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 54Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Indonesia

Frequently asked questions

How long did the Kupang fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 14 August 2026 to 25 August 2026 (12 days). The perimeter dates it from 15 August 2026 to 25 August 2026.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,913 hectares (29.1 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Kupang (2,933 ha, 0.6 %).
What was the weather like?
During the fire the temperature reached 34.0 °C, humidity dropped to 26 % and gusts hit 58 km/h. The fire danger index (FWI) reached 50, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Indonesia (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 112 · Emergency number and official warnings

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 15 August 2026 to 25 August 2026. 54 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.