Skip to content
worldfires
CM · Cameroon · –

Kentzou fire, 22 December 2024 Kentzou

Out · last detection 1 Jan 2025, 12:40 UTC

The fire started on 22 December 2024 in Kentzou, Cameroon, and satellites saw it burning for 13 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,549 hectares from heat detections, spread across a single municipality.

It is the 96th largest in East since 2016 (of 224 with a page). Number 73 in Cameroon in 2024, of 195.

Burnt area
1,549ha
GWIS perimeter (Copernicus)
Duration
13days
22 Dec 2024 – 3 Jan 2025
Municipalities hit
1
communes
Started on
22 Dec
2024
Heat detections
51
in a single hotspot: 49 MW
Danger at start
30
High · FWI index
Average daily power
81MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 22 Dec3 Jan
1 Jan 2025

How it evolved, day by day

22 Dec 2024 · 12 MW · 2 25 Dec 2024 · 34 MW · 3 26 Dec 2024 · 26 MW · 2 27 Dec 2024 · 11 MW · 3 28 Dec 2024 · 9 MW · 1 30 Dec 2024 · 37 MW · 2 31 Dec 2024 · 457 MW · 35 1 Jan 2025 · 60 MW · 3
22 Dec 26 Dec 28 Dec 31 Dec

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
40km/h · peak gust
18%lowest humidity

It had gone 41 days without rain (1 mm or more) when it started.

This area had burned before

52% of the perimeter overlaps earlier fires recorded since 2016: 103 ha in 2016, 707 ha in 2023.

How big is it?

10 km
It burned the equivalent of 1% of the area of London (15 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Kentzou where it started
    1,559 ha reached on 22 Dec
    1.5 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
22 Dec 32.8 °C 32 % 22 km/h 0.0 mm High 30
23 Dec 32.5 °C 26 % 16 km/h 0.0 mm High 30
24 Dec 33.3 °C 28 % 23 km/h 0.0 mm High 32
25 Dec 32.4 °C 33 % 18 km/h 0.0 mm High 30
26 Dec 32.7 °C 29 % 27 km/h 0.0 mm High 31
27 Dec 32.5 °C 27 % 20 km/h 0.0 mm High 30
28 Dec 32.9 °C 30 % 27 km/h 0.0 mm High 34
29 Dec 34.1 °C 23 % 26 km/h 0.0 mm High 34
30 Dec 35.5 °C 20 % 35 km/h 0.0 mm Very high 42
31 Dec 34.9 °C 18 % 40 km/h 0.0 mm Very high 45
1 Jan 33.9 °C 20 % 34 km/h 0.0 mm Very high 42
2 Jan 33.5 °C 21 % 29 km/h 0.0 mm Very high 40
3 Jan 32.7 °C 28 % 20 km/h 0.0 mm High 35
4 Jan after 32.4 °C 39 % 24 km/h 0.0 mm High 30
5 Jan after 32.4 °C 35 % 20 km/h 0.0 mm High 28
6 Jan after 33.1 °C 27 % 18 km/h 0.0 mm High 31
7 Jan after 32.1 °C 41 % 21 km/h 0.0 mm High 29
8 Jan after 32.8 °C 31 % 24 km/h 0.0 mm High 28
9 Jan after 31.4 °C 25 % 19 km/h 0.0 mm High 31
10 Jan after 32.5 °C 23 % 19 km/h 0.0 mm High 32
11 Jan after 31.8 °C 22 % 24 km/h 0.0 mm High 35
12 Jan after 31.7 °C 25 % 23 km/h 0.0 mm High 33
13 Jan after 32.5 °C 27 % 20 km/h 0.0 mm High 34

Its twins: fires that started in the same weather

It started with an FWI of 30.1, a minimum humidity of 32% and 41 days without rain. Fires in the area that started in weather like this since 2016: 15.

FWI at the start 30.1
Minimum humidity 32 %
Days without rain 41
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Bélabo fire, February 2023
6,649 ha 20 days FWI 31.5 Min. humidity 33 % 193 km away, in 2023

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

12 days
median duration
1,651 ha
median area
100 %
went past 1,000 ha
1.5 mm
rain at the end (median; 5 of 15 had it)

It burned an area similar to its twins (1,549 ha against a median of 1,651 ha) and lasted 13 days, against 12 days.

In 10 of 15, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.5 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
40km/h · max. gust

It was considered over on 3 Jan, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 5 of 15, with a median of 1.5 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 15 Dec 2024
After · 10 Jan 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 3 January 2025 the air beside the fire reached 82 µg/m³ of PM2.5. That day averaged 60: 4.0 times the WHO daily guideline (15).

PM2.5 peak82 µg/m³
Days over the guideline9 days
PM1097 µg/m³
Optical depth0.79
27 Dec29 Dec31 Dec2 Jan4 Jan
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 51Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Cameroon

Frequently asked questions

How long did the Kentzou fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 22 December 2024 to 3 January 2025 (13 days). The perimeter dates it from 29 December 2024 to 1 January 2025.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,549 hectares (15.5 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Kentzou (1,559 ha, 1.5 %).
What was the weather like?
During the fire the temperature reached 35.5 °C, humidity dropped to 18 % and gusts hit 40 km/h. The fire danger index (FWI) reached 45, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Cameroon (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 15. Their median duration was 12 days and their median area 1,651 ha; 100 % went past 1,000 ha. In 10 of 15, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.5 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 2 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 1 January 2025 → 3 January 2025.
  2. Start date: 29 December 2024 → 22 December 2024.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 29 December 2024 to 1 January 2025. 51 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.