Skip to content
worldfires
CD · Democratic Republic of the Congo · →

Kamina fire, 19 August 2026 Kamina

Out · last detection 27 Aug 2026, 12:42 UTC

The fire started on 19 August 2026 in Kamina, Democratic Republic of the Congo, and satellites saw it burning for 9 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,288 hectares from heat detections, spread across a single municipality.

It is the 146th largest in Haut-Lomami since 2016 (of 173 with a page). Number 478 in Democratic Republic of the Congo in 2026, of 523.

Compare with…
Burnt area
5,288ha
GWIS perimeter (Copernicus)
Duration
9days
19 Aug 2026 – 27 Aug 2026
Municipalities hit
1
territories
Started on
19 Aug
2026
Heat detections
52
in a single hotspot: 168 MW
Danger at start
46
Very high · FWI index
Average daily power
376MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 19 Aug27 Aug
27 Aug 2026

How it evolved, day by day

21 Aug 2026 · 135 MW · 8 22 Aug 2026 · 8 MW · 1 23 Aug 2026 · 164 MW · 16 24 Aug 2026 · 42 MW · 6 27 Aug 2026 · 1,533 MW · 21
21 Aug 22 Aug 23 Aug 24 Aug 27 Aug

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

33°high
46km/h · peak gust
13%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started. Rain came after the fire: 2.0 mm on 5 Sept.

This area had burned before

50% of the perimeter overlaps earlier fires recorded since 2016: 95 ha in 2017, 1,101 ha in 2018, 97 ha in 2019, 697 ha in 2020, 1,230 ha in 2021, 378 ha in 2022, 181 ha in 2023, 69 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 2,645 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 3.3% of the area of London (53 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Kamina where it started
    5,328 ha reached on 21 Aug
    0.1 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
19 Aug 31.7 °C 13 % 36 km/h 0.0 mm Very high 46
20 Aug 31.5 °C 13 % 32 km/h 0.0 mm Very high 46
21 Aug 30.7 °C 17 % 31 km/h 0.0 mm Very high 44
22 Aug 31.9 °C 19 % 33 km/h 0.0 mm Very high 45
23 Aug 32.5 °C 18 % 38 km/h 0.0 mm Very high 48
24 Aug 32.2 °C 20 % 40 km/h 0.0 mm Very high 47
25 Aug 32.8 °C 23 % 41 km/h 0.0 mm Very high 46
26 Aug 30.7 °C 28 % 37 km/h 0.0 mm Very high 40
27 Aug 32.8 °C 25 % 46 km/h 0.0 mm Very high 45
28 Aug after 30.7 °C 28 % 41 km/h 0.0 mm Very high 42
29 Aug after 32.2 °C 21 % 42 km/h 0.0 mm Very high 43
30 Aug after 32.6 °C 18 % 41 km/h 0.0 mm Very high 44
31 Aug after 32.8 °C 20 % 35 km/h 0.0 mm Very high 42
1 Sept after 33.6 °C 19 % 44 km/h 0.0 mm Very high 46
2 Sept after 32.4 °C 21 % 33 km/h 0.0 mm Very high 40
3 Sept after 32.7 °C 24 % 31 km/h 0.0 mm Very high 42
4 Sept after 32.0 °C 32 % 32 km/h 0.1 mm High 38
5 Sept after 29.9 °C 40 % 28 km/h 2.0 mm Moderate 13

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 12 Aug 2026
After · 3 Sept 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 20 August 2026 the air beside the fire reached 156 µg/m³ of PM2.5. That day averaged 87: 5.8 times the WHO daily guideline (15).

PM2.5 peak156 µg/m³
Days over the guideline10 days
PM10161 µg/m³
Optical depth1.25
17181920212223242526
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 52Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Democratic Republic of the Congo ›

Frequently asked questions

How long did the Kamina fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 19 August 2026 to 27 August 2026 (9 days). The perimeter dates it from 19 August 2026 to 23 August 2026.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,288 hectares (52.9 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Kamina (5,328 ha, 0.1 %).
What was the weather like?
During the fire the temperature reached 32.8 °C, humidity dropped to 13 % and gusts hit 46 km/h. The fire danger index (FWI) reached 48, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Democratic Republic of the Congo (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 23 August 2026 → 27 August 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 19 August 2026 to 23 August 2026. 52 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.