Skip to content
worldfires
SS · South Sudan · –

Kajo-keji fire, January 2024 Kajo-keji

Out · last detection

The fire started on in Kajo-keji, South Sudan, and satellites saw it burning for 8 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,122 hectares from heat detections, spread across a single municipality.

It is number 47 by size of the 50 fires with a page that started in Central Equatoria since 2016. Number 169 in South Sudan in 2024, of 180.

Burnt area
5,122ha
GWIS perimeter (Copernicus)
Duration
8days
5 Jan 2024 – 12 Jan 2024
Municipalities hit
1
counties
Started on
5 Jan
2024
Heat detections
124
in a single hotspot: 0 MW
Danger at start
39
Very high · FWI index
Average daily power
145MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 5 Jan12 Jan
13 Jan 2024

How it evolved, day by day

5 Jan 2024 · 20 MW · 1 6 Jan 2024 · 56 MW · 7 7 Jan 2024 · 318 MW · 35 8 Jan 2024 · 183 MW · 22 9 Jan 2024 · 554 MW · 40 10 Jan 2024 · 109 MW · 7 11 Jan 2024 · 48 MW · 8 12 Jan 2024 · 10 MW · 2 13 Jan 2024 · 7 MW · 2
5 Jan 7 Jan 9 Jan 11 Jan 13 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

35°high
34km/h · peak gust
19%lowest humidity

It had gone 23 days without rain (1 mm or more) when it started.

This area had burned before

67% of the perimeter overlaps earlier fires recorded since 2016: 986 ha in 2017, 1,794 ha in 2018, 11 ha in 2019, 1,817 ha in 2021. Part of it burned more than once, so the yearly figures add up to more than the 3,445 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 3.2% of the area of London (51 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Kajo-keji where it started
    5,156 ha
    2.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents≈ 90

Inside the perimeter there were about 0.08 hectares of built-up land and about 90 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
5 Jan 33.5 °C 23 % 17 km/h 0.0 mm Very high 39
6 Jan 34.0 °C 21 % 23 km/h 0.0 mm Very high 40
7 Jan 33.5 °C 20 % 27 km/h 0.0 mm Very high 47
8 Jan 35.1 °C 19 % 32 km/h 0.0 mm Extreme 52
9 Jan 34.5 °C 23 % 27 km/h 0.0 mm Very high 47
10 Jan 34.5 °C 23 % 34 km/h 0.0 mm Extreme 53
11 Jan 34.8 °C 23 % 28 km/h 0.0 mm Very high 47
12 Jan 34.4 °C 20 % 34 km/h 0.0 mm Extreme 54
13 Jan after 33.2 °C 27 % 23 km/h 0.0 mm Very high 39
14 Jan after 33.7 °C 29 % 23 km/h 0.0 mm High 35
15 Jan after 34.2 °C 22 % 30 km/h 0.0 mm Very high 42
16 Jan after 33.2 °C 18 % 35 km/h 0.0 mm Extreme 55
17 Jan after 32.7 °C 18 % 30 km/h 0.0 mm Extreme 50
18 Jan after 31.3 °C 25 % 24 km/h 0.0 mm Very high 46
19 Jan after 33.9 °C 23 % 26 km/h 0.0 mm Very high 43
20 Jan after 34.4 °C 11 % 35 km/h 0.0 mm Extreme 63
21 Jan after 33.5 °C 13 % 37 km/h 0.0 mm Extreme 63
22 Jan after 34.5 °C 17 % 24 km/h 0.0 mm Extreme 53

Its twins: fires that started in the same weather

It started with an FWI of 39.3, a minimum humidity of 23% and 23 days without rain. Fires in the area that started in weather like this since 2016: 33.

FWI at the start 39.3
Minimum humidity 23 %
Days without rain 23
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Magwi fire, December 2017
5,518 ha 9 days FWI 40.3 Min. humidity 23 % 45 km away, in 2017

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

8 days
median duration
1,915 ha
median area
100 %
went past 1,000 ha
2.2 mm
rain at the end (median; 11 of 33 had it)

It was 2.7 times larger than the median of its twins and lasted 8 days, against 8 days.

Only 5 of its 33 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 22 of 33, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.2 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
34km/h · max. gust

It was considered over on 12 Jan, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 11 of 33, with a median of 2.2 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 29 Dec 2023
After · 19 Jan 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 9 January 2024 the air beside the fire reached 90 µg/m³ of PM2.5. That day averaged 56: 3.7 times the WHO daily guideline (15).

PM2.5 peak90 µg/m³
Days over the guideline13 days
PM10129 µg/m³
Optical depth1.38
3 Jan6 Jan9 Jan12 Jan15 Jan
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 0Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in South Sudan

Frequently asked questions

How long did the Kajo-keji fire last?
GWIS (Copernicus) dates it between 5 January 2024 and 12 January 2024: 8 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,122 hectares (51.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Kajo-keji (5,156 ha, 2.0 %).
What was the weather like?
During the fire the temperature reached 35.1 °C, humidity dropped to 19 % and gusts hit 34 km/h. The fire danger index (FWI) reached 54, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of South Sudan (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 33. Their median duration was 8 days and their median area 1,915 ha; 100 % went past 1,000 ha. Only 5 of its 33 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 22 of 33, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.2 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 4 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 19 January 2024 → 12 January 2024.
  2. Start date: 29 December 2023 → 5 January 2024.
  3. Last day with fire: 12 January 2024 → 19 January 2024.
  4. Start date: 5 January 2024 → 29 December 2023.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. No Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.