Skip to content
worldfires
CD · Congo - Kinshasa · →

Kabongo fire, 31 July 2025 Kabongo

Out · last detection 6 Aug 2025, 11:29 UTC

The fire started on 31 July 2025 in Kabongo, Congo - Kinshasa, and satellites saw it burning for 7 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,493 hectares from heat detections, spread across a single municipality.

It is the 131th largest in Haut-Lomami since 2016 (of 172 with a page). Number 100 in Congo - Kinshasa in 2025, of 118.

Burnt area
5,493ha
GWIS perimeter (Copernicus)
Duration
7days
31 Jul 2025 – 6 Aug 2025
Municipalities hit
1
territories
Started on
31 Jul
2025
Heat detections
204
in a single hotspot: 86 MW
Danger at start
41
Very high · FWI index
Energy released
1.9GW
sum of detected power

Where it burned

6 Aug 2025
HOTSPOTS BY DAY 31 Jul6 Aug

How it evolved, day by day

31123456

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

32°high
45km/h · peak gust
17%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

89% of the perimeter overlaps earlier fires recorded since 2016: 769 ha in 2016, 3,364 ha in 2017, 1,627 ha in 2018, 1,036 ha in 2019, 956 ha in 2020, 1,550 ha in 2021, 1,837 ha in 2022, 1,668 ha in 2023, 1,298 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 4,873 ha that had burned before.

What happened to each town

  1. Kabongo where it started
    5,523 ha reached on 29 Jul
    0.3 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
31 Jul 31.0 °C 21 % 42 km/h 0.0 mm Very high 41
1 Aug 31.3 °C 21 % 38 km/h 0.0 mm Very high 40
2 Aug 32.5 °C 21 % 42 km/h 0.0 mm Very high 42
3 Aug 31.5 °C 17 % 45 km/h 0.0 mm Very high 47
4 Aug 31.4 °C 19 % 43 km/h 0.0 mm Very high 46
5 Aug 31.8 °C 21 % 42 km/h 0.0 mm Very high 46
6 Aug 32.0 °C 24 % 20 km/h 0.0 mm Very high 38
7 Aug after 31.6 °C 27 % 30 km/h 0.0 mm High 38
8 Aug after 30.8 °C 33 % 20 km/h 0.0 mm High 32
9 Aug after 32.9 °C 27 % 22 km/h 0.0 mm High 33
10 Aug after 30.6 °C 35 % 22 km/h 0.0 mm High 32
11 Aug after 31.0 °C 34 % 31 km/h 0.0 mm High 31
12 Aug after 32.0 °C 19 % 35 km/h 0.0 mm Very high 40
13 Aug after 32.8 °C 22 % 36 km/h 0.0 mm Very high 41
14 Aug after 32.7 °C 22 % 27 km/h 0.0 mm High 36
15 Aug after 32.6 °C 21 % 26 km/h 0.0 mm Very high 41
16 Aug after 28.8 °C 36 % 28 km/h 0.1 mm High 35

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 24 Jul 2025
After · 13 Aug 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 7 August 2025 the air beside the fire reached 122 µg/m³ of PM2.5. That day averaged 83: 5.6 times the WHO daily guideline (15).

PM2.5 peak122 µg/m³
Days over the guideline12 days
PM10122 µg/m³
Optical depth1.68
293031123456789
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 204Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Congo - Kinshasa ›

Frequently asked questions

How long did the Kabongo fire last?
GWIS (Copernicus) dates it between 31 July 2025 and 6 August 2025: 7 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,493 hectares (54.9 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Kabongo (5,523 ha, 0.3 %).
What was the weather like?
During the fire the temperature reached 32.5 °C, humidity dropped to 17 % and gusts hit 45 km/h. The fire danger index (FWI) reached 47, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Congo - Kinshasa (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.