Islas del Ibicuy fire, 20 February 2023 Islas del Ibicuy

Out · last detection

The fire started on in Islas del Ibicuy, Argentina, and satellites saw it burning for 20 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,424 hectares from heat detections, spread across a single municipality.

It is number 94 by size of the 203 fires with a page that started in Buenos Aires since 2016. Number 78 in Argentina in 2023, of 179.

Burnt area
2,424ha
GWIS perimeter (Copernicus)
Duration
20days
20 Feb 2023 – 11 Mar 2023
Municipalities hit
1
departments
Started on
20 Feb
2023
Heat detections
382
in a single hotspot: 167 MW
Danger at start
24
High · FWI index
Average daily power
343MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 20 Feb11 Mar
11 Mar 2023

How it evolved, day by day

20 Feb 2023 · 98 MW · 7 21 Feb 2023 · 257 MW · 14 22 Feb 2023 · 10 MW · 4 24 Feb 2023 · 21 MW · 6 25 Feb 2023 · 381 MW · 23 26 Feb 2023 · 332 MW · 33 27 Feb 2023 · 627 MW · 55 28 Feb 2023 · 615 MW · 40 1 Mar 2023 · 3,280 MW · 70 2 Mar 2023 · 571 MW · 84 3 Mar 2023 · 47 MW · 16 4 Mar 2023 · 38 MW · 6 5 Mar 2023 · 62 MW · 2 6 Mar 2023 · 54 MW · 3 7 Mar 2023 · 73 MW · 9 8 Mar 2023 · 32 MW · 7 9 Mar 2023 · 1 MW · 1 10 Mar 2023 · 9 MW · 1 11 Mar 2023 · 12 MW · 1
20 Feb 25 Feb 1 Mar 5 Mar 9 Mar

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

39°high
37km/h · peak gust
26%lowest humidity

It had gone 3 days without rain (1 mm or more) when it started. Rain came after the fire: 10.5 mm on 15 Mar.

This area had burned before

58% of the perimeter overlaps earlier fires recorded since 2016: 315 ha in 2020, 1,100 ha in 2021, 516 ha in 2022. Part of it burned more than once, so the yearly figures add up to more than the 1,394 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.5% of the area of London (24 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Islas del Ibicuy where it started
    2,437 ha reached on 20 Feb
    0.5 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
20 Feb 29.2 °C 29 % 23 km/h 0.0 mm High 24
21 Feb 31.5 °C 33 % 28 km/h 0.0 mm High 28
22 Feb 31.2 °C 37 % 35 km/h 0.0 mm High 32
23 Feb 26.6 °C 63 % 37 km/h 1.7 mm Moderate 17
24 Feb 30.1 °C 37 % 25 km/h 0.0 mm Low 10
25 Feb 32.5 °C 35 % 32 km/h 0.0 mm Moderate 21
26 Feb 30.2 °C 37 % 31 km/h 0.0 mm High 25
27 Feb 32.5 °C 32 % 26 km/h 0.0 mm High 22
28 Feb 35.7 °C 33 % 29 km/h 0.0 mm High 33
1 Mar 36.1 °C 31 % 30 km/h 0.0 mm Very high 39
2 Mar 36.8 °C 26 % 19 km/h 0.0 mm High 35
3 Mar 34.3 °C 40 % 30 km/h 1.2 mm High 33
4 Mar 34.5 °C 44 % 30 km/h 0.3 mm Moderate 20
5 Mar 35.5 °C 38 % 24 km/h 0.0 mm High 24
6 Mar 34.7 °C 29 % 36 km/h 0.0 mm High 35
7 Mar 33.3 °C 37 % 31 km/h 0.0 mm High 29
8 Mar 34.5 °C 41 % 27 km/h 0.0 mm High 23
9 Mar 35.9 °C 32 % 25 km/h 0.0 mm High 28
10 Mar 37.0 °C 35 % 36 km/h 0.1 mm High 33
11 Mar 38.7 °C 28 % 22 km/h 0.0 mm High 35
12 Mar after 37.5 °C 25 % 37 km/h 0.0 mm Very high 39
13 Mar after 36.0 °C 37 % 37 km/h 0.1 mm High 36
14 Mar after 35.2 °C 39 % 30 km/h 0.1 mm High 36
15 Mar after 29.5 °C 69 % 29 km/h 10.5 mm Moderate 14

Its twins: fires that started in the same weather

It started with an FWI of 23.6, a minimum humidity of 29% and 3 days without rain. Fires in the area that started in weather like this since 2016: 15.

FWI at the start 23.6
Minimum humidity 29 %
Days without rain 3
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Gualeguay fire, October 2020
5,900 ha 10 days FWI 23.4 Min. humidity 29 % 108 km away, in 2020

First rain (1 mm or more) after it ended: 3.3 mm on 19 Oct.

What happened to them

10 days
median duration
1,920 ha
median area
100 %
went past 1,000 ha
9.5 mm
rain at the end (median; 15 of 15 had it)

It burned an area similar to its twins (2,424 ha against a median of 1,920 ha) and lasted 20 days, against 10 days.

All of them had rain in the ten days after the end: the first rainy day brought a median of 9.5 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

10.5 mmfirst rain
15 Mar4 days after it ended
37km/h · max. gust

It was considered over on 11 Mar, and on 15 Mar 10.5 mm fell. We do not know whether the rain or the firefighters put it out. Twins with rain when they ended: 15 of 15, with a median of 9.5 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 13 Feb 2023
After · 18 Mar 2023

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 2 March 2023 the air beside the fire reached 130 µg/m³ of PM2.5. That day averaged 77: 5.1 times the WHO daily guideline (15).

PM2.5 peak130 µg/m³
Days over the guideline10 days
PM10186 µg/m³
Optical depth0.54
18 Feb23 Feb28 Feb5 Mar10 Mar
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 382Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Argentina

Frequently asked questions

How long did the Islas del Ibicuy fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 20 February 2023 to 11 March 2023 (20 days). The perimeter dates it from 20 February 2023 to 9 March 2023.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,424 hectares (24.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Islas del Ibicuy (2,437 ha, 0.5 %).
What was the weather like?
During the fire the temperature reached 38.7 °C, humidity dropped to 26 % and gusts hit 37 km/h. The fire danger index (FWI) reached 39, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Argentina (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 15. Their median duration was 10 days and their median area 1,920 ha; 100 % went past 1,000 ha. All of them had rain in the ten days after the end: the first rainy day brought a median of 9.5 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 911 · 100 · Emergency number and official warnings

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 9 March 2023 → 11 March 2023.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 911 · 100.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 20 February 2023 to 9 March 2023. 382 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.