Skip to content
worldfires
SS · South Sudan · →

Guit fire, February 2024 Guit

Out · last detection 11 Mar 2024, 11:51 UTC

The fire started on 28 February 2024 in Guit, South Sudan, and satellites saw it burning for 13 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 12,235 hectares from heat detections, spread across a single municipality.

It is the 13th largest in Unity since 2016 (of 86 with a page). Number 41 in South Sudan in 2024, of 180.

Compare with…

Suggestions: Guit · 2016Koch · 2024

Burnt area
12,235ha
GWIS perimeter (Copernicus)
Duration
13days
28 Feb 2024 – 11 Mar 2024
Municipalities hit
1
counties
Started on
28 Feb
2024
Heat detections
331
in a single hotspot: 104 MW
Danger at start
66
Extreme · FWI index
Average daily power
301MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 28 Feb11 Mar
11 Mar 2024

How it evolved, day by day

28 Feb 2024 · 4 MW · 3 29 Feb 2024 · 65 MW · 15 1 Mar 2024 · 439 MW · 14 2 Mar 2024 · 29 MW · 5 3 Mar 2024 · 276 MW · 18 4 Mar 2024 · 205 MW · 20 5 Mar 2024 · 59 MW · 8 6 Mar 2024 · 322 MW · 24 7 Mar 2024 · 1,402 MW · 98 8 Mar 2024 · 596 MW · 64 9 Mar 2024 · 182 MW · 15 10 Mar 2024 · 311 MW · 23 11 Mar 2024 · 20 MW · 2
28 Feb 1 Mar 3 Mar 5 Mar 7 Mar 9 Mar 11 Mar

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

44°high
42km/h · peak gust
4%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

27% of the perimeter overlaps earlier fires recorded since 2016: 78 ha in 2016, 1,593 ha in 2017, 634 ha in 2018, 1,038 ha in 2019, 840 ha in 2020, 5 ha in 2021. Part of it burned more than once, so the yearly figures add up to more than the 3,329 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 7.7% of the area of London (122 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Guit where it started
    12,307 ha reached on 21 Feb
    3.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area2.5 ha
Residents≈ 1,100

Inside the perimeter there were about 2.5 hectares of built-up land and about 1,100 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
28 Feb 41.3 °C 6 % 37 km/h 0.0 mm Extreme 66
29 Feb 40.7 °C 5 % 37 km/h 0.0 mm Extreme 66
1 Mar 42.0 °C 4 % 31 km/h 0.0 mm Extreme 62
2 Mar 42.6 °C 7 % 30 km/h 0.0 mm Extreme 62
3 Mar 42.7 °C 5 % 34 km/h 0.0 mm Extreme 65
4 Mar 42.2 °C 4 % 31 km/h 0.0 mm Extreme 64
5 Mar 41.7 °C 4 % 32 km/h 0.0 mm Extreme 65
6 Mar 41.1 °C 6 % 40 km/h 0.0 mm Very extreme 72
7 Mar 40.3 °C 7 % 41 km/h 0.0 mm Very extreme 74
8 Mar 41.2 °C 5 % 41 km/h 0.0 mm Very extreme 75
9 Mar 42.3 °C 5 % 42 km/h 0.0 mm Very extreme 76
10 Mar 42.1 °C 5 % 31 km/h 0.0 mm Extreme 64
11 Mar 43.9 °C 8 % 31 km/h 0.0 mm Extreme 66
12 Mar after 42.6 °C 13 % 31 km/h 0.0 mm Extreme 61
13 Mar after 43.9 °C 12 % 36 km/h 0.0 mm Extreme 64
14 Mar after 43.3 °C 14 % 48 km/h 0.0 mm Very extreme 79
15 Mar after 41.7 °C 18 % 48 km/h 0.0 mm Very extreme 70
16 Mar after 41.3 °C 18 % 30 km/h 0.0 mm Extreme 54
17 Mar after 42.3 °C 16 % 32 km/h 0.0 mm Extreme 55
18 Mar after 43.4 °C 12 % 30 km/h 0.0 mm Extreme 57
19 Mar after 40.7 °C 16 % 51 km/h 0.0 mm Very extreme 75
20 Mar after 40.9 °C 13 % 42 km/h 0.0 mm Extreme 67
21 Mar after 41.5 °C 12 % 39 km/h 0.0 mm Extreme 62

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 21 Feb 2024
After · 18 Mar 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 7 March 2024 the air beside the fire reached 35 µg/m³ of PM2.5. That day averaged 27: 1.8 times the WHO daily guideline (15).

PM2.5 peak35 µg/m³
Days over the guideline14 days
PM10112 µg/m³
Optical depth0.53
262728291234567891011121314
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 331Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in South Sudan ›

Frequently asked questions

How long did the Guit fire last?
GWIS (Copernicus) dates it between 28 February 2024 and 11 March 2024: 13 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 12,235 hectares (122.4 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Guit (12,307 ha, 3.6 %).
What was the weather like?
During the fire the temperature reached 43.9 °C, humidity dropped to 4 % and gusts hit 42 km/h. The fire danger index (FWI) reached 76, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of South Sudan (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 331 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.