Skip to content
worldfires
VE · Venezuela · →

Guanare fire, March 2016 San Genaro de Boconoito, Guanare

Out · last detection 15 Mar 2016, 18:50 UTC

The fire started on 5 March 2016 in Guanare, Venezuela, and satellites saw it burning for 10 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,695 hectares from heat detections, spread across 2 municipalities.

It is the 14th largest in Portuguesa since 2016 (of 36 with a page). Number 69 in Venezuela in 2016, of 238.

The power measured by the satellite is low (19.2 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
2,695ha
GWIS perimeter (Copernicus)
Duration
10days
5 Mar 2016 – 14 Mar 2016
Municipalities hit
2
municipalities
Started on
5 Mar
2016
Heat detections
84
in a single hotspot: 19 MW
Danger at start
21
Moderate · FWI index
Energy released
393MW
sum of detected power

Where it burned

15 Mar 2016
HOTSPOTS BY DAY 5 Mar14 Mar

How it evolved, day by day

57891012131415

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
30km/h · peak gust
31%lowest humidity

It had gone 3 days without rain (1 mm or more) when it started. Rain came after the fire: 1.7 mm on 16 Mar.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

What happened to each town

  1. 2,561 ha reached on 7 Mar
    2.1 %
  2. Guanare 192,644 inhabitants where it started
    152 ha reached on 5 Mar
    0.1 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
5 Mar 34.6 °C 42 % 22 km/h 0.0 mm Moderate 21
6 Mar 34.3 °C 43 % 19 km/h 0.0 mm High 22
7 Mar 36.3 °C 35 % 28 km/h 0.0 mm High 26
8 Mar 34.9 °C 39 % 25 km/h 0.0 mm High 24
9 Mar 34.9 °C 35 % 30 km/h 0.0 mm High 26
10 Mar 36.2 °C 32 % 30 km/h 0.0 mm High 28
11 Mar 33.5 °C 41 % 27 km/h 0.1 mm High 26
12 Mar 33.2 °C 38 % 26 km/h 0.0 mm High 26
13 Mar 34.6 °C 31 % 23 km/h 0.0 mm High 26
14 Mar 34.6 °C 39 % 25 km/h 0.0 mm High 26
15 Mar after 33.2 °C 49 % 24 km/h 1.5 mm Moderate 11
16 Mar after 32.8 °C 60 % 23 km/h 1.7 mm Low 7

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 27 Feb 2016
After · 21 Mar 2016

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 84Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Venezuela ›

Frequently asked questions

How long did the Guanare fire last?
GWIS (Copernicus) dates it between 5 March 2016 and 14 March 2016: 10 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,695 hectares (27.0 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: San Genaro de Boconoito (2,561 ha, 2.1 %); Guanare (152 ha, 0.1 %).
What was the weather like?
During the fire the temperature reached 36.3 °C, humidity dropped to 31 % and gusts hit 30 km/h. The fire danger index (FWI) reached 28, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Venezuela (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 911

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 911.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.