Guadalupe y Calvo fire, 8 June 2023
Guadalupe y Calvo, Badiraguato
Out · last detection
The fire started on in Guadalupe y Calvo, Mexico, and satellites saw it burning for 15 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 4,774 hectares from heat detections, spread across 2 municipalities. According to CONAFOR, the largest of the 3 recorded fires was detected on 6 June 2023 and declared extinguished on 22 June 2023.
It is number 53 by size of the 229 fires with a page that started in Chihuahua since 2016. Number 44 in Mexico in 2023, of 285.
This is an index computed from weather model data, not a measurement of the fire nor an official warning. Danger warnings are issued by each country’s authority. Emergency number and official warnings ›
Weather during the fire
model
38.2°C · 11% RH
High of 38.2 °C and minimum humidity of 11% on 13 June 2023; gusts of 55 km/h on 10 June 2023.
These are model values for a cell of about 25 km, not from a weather station: they may differ from what was measured on the ground.
ⓘThis page’s change log has been kept since 24 October 2026: every night what it publishes is compared and the difference is logged. Anything earlier is reconstructed from each source’s date and marked as reconstructed.
Show
· reconstructedofficial
Matched with the official CONAFOR record
Matches: 3,895 ha in the official record (records: 3).
A version keeps the area, dates, name and official record; the area as it was logged (changes under 2% are not logged). The map, hotspots and weather always show today’s data.
Citation
A lede of about 60 words figures only, no adjectives
Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.
The weather it burned in
38°high
55km/h · peak gust
11%lowest humidity
It had gone 54 days without rain (1 mm or more) when it started. Rain came after the fire: 1.2 mm on 23 Jun.
This area had burned before
78% of the perimeter overlaps earlier fires recorded since 2016: 2,709 ha in 2016, 2,843 ha in 2018, 39 ha in 2021. Part of it burned more than once, so the yearly figures add up to more than the 3,710 ha that had burned before.
Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.
People and buildings inside the perimeter
GHSL 2025
Built-up area< 0.1ha
Residents< 20
Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2025, satellite-based estimate).
This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.
According to CONAFOR, 3 fires started inside this perimeter on these dates, totalling 3,895 ha (the satellite measured 4,774 ha).
CONAFOR records each fire that started at a different time or place separately; the satellite sees a single burned area, so this page groups them together. The numbers on the map show where each one started.
ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.
Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)
Day
High
Min. humidity
Peak gust
Rain
Danger (FWI)
8 Jun
31.4 °C
24 %
49 km/h
0.0 mm
Very high 48
9 Jun
34.0 °C
22 %
48 km/h
0.0 mm
Very high 48
10 Jun
33.9 °C
21 %
55 km/h
0.0 mm
Extreme 54
11 Jun
35.4 °C
20 %
55 km/h
0.0 mm
Extreme 53
12 Jun
35.8 °C
17 %
50 km/h
0.0 mm
Extreme 53
13 Jun
38.2 °C
11 %
53 km/h
0.0 mm
Extreme 61
14 Jun
35.9 °C
18 %
51 km/h
0.0 mm
Extreme 62
15 Jun
36.9 °C
19 %
54 km/h
0.0 mm
Extreme 56
16 Jun
37.4 °C
24 %
38 km/h
2.1 mm
Very high 43
17 Jun
36.8 °C
25 %
45 km/h
0.6 mm
High 34
18 Jun
35.0 °C
33 %
40 km/h
2.8 mm
High 35
19 Jun
35.5 °C
34 %
36 km/h
1.2 mm
Moderate 16
20 Jun
36.5 °C
31 %
36 km/h
3.3 mm
High 25
21 Jun
37.4 °C
32 %
37 km/h
2.1 mm
Moderate 14
22 Jun
37.3 °C
31 %
42 km/h
3.5 mm
Moderate 12
23 Jun after
36.9 °C
33 %
41 km/h
1.2 mm
Moderate 14
Its twins: fires that started in the same weather
It started with an FWI of 47.7, a minimum humidity of 24% and 54 days without rain. Fires in the area that started in weather like this since 2016: 15.
FWI at the start47.7
Minimum humidity24 %
Days without rain54
this firechosen twinsrest of the area
Almost identicalSimilar
Outlines of the closest twins
This fire · Guadalupe y Calvo fire, 8 June 2023
4,774 ha15 daysFWI 47.7Min. humidity 24 %
Badiraguato fire, April 2018
3,397 ha16 daysFWI 46.6Min. humidity 24 %56 km away, in 2018
First rain (1 mm or more) after it ended: none in the following ten days.
It burned an area similar to its twins (4,774 ha against a median of 3,542 ha) and lasted 15 days, against 11 days.
In 7 of 15, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.6 mm.
This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it
How it ended
1.2 mmfirst rain
23 Junthe day after it ended
55km/h · max. gust
It was considered over on 22 Jun, and on 23 Jun 1.2 mm fell. We do not know whether the rain or the firefighters put it out. Twins with rain when they ended: 8 of 15, with a median of 1.6 mm.
Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)
How a twin is chosen
Same area: fires that have already ended, less than 250 km from this one, since 2016.
Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
They are sorted by similarity, and the outlines of the first five are drawn.
Drag the line to compare the same ground before the fire and after it.
↔
Before · 1 Jun 2023
After · 29 Jun 2023
Sentinel-2 did not pass over on that day. Try another date, or use false colour, which is daily.
If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.
The smoke
CAMS · Copernicus
On 16 June 2023 the air beside the fire reached 78 µg/m³ of PM2.5. That day averaged 41: 2.7 times the WHO daily guideline (15).
PM2.5 peak78µg/m³
Days over the guideline3days
PM10111µg/m³
Optical depth0.68
WHO 15
7 Jun10 Jun13 Jun16 Jun19 Jun
GoodFairModeratePoorVery poorExtremely poor
Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.
Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)
Detections table· 269Every satellite heat detection, one by one, with time, satellite, power and coordinates.›
⬇ Download CSVTimes in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
According to the heat detections seen by satellite inside the perimeter, it burned from 8 June 2023 to 22 June 2023 (15 days). The perimeter dates it from 9 June 2023 to 18 June 2023. According to CONAFOR, the largest of the 3 recorded fires was detected on 6 June 2023 and declared extinguished on 22 June 2023.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 4,774 hectares (47.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Guadalupe y Calvo (4,248 ha, 0.4 %); Badiraguato (549 ha, 0.1 %).
What was the weather like?
During the fire the temperature reached 38.2 °C, humidity dropped to 11 % and gusts hit 55 km/h. The fire danger index (FWI) reached 62, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mexico (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 15. Their median duration was 11 days and their median area 3,542 ha; 7 % went past 10,000 ha. In 7 of 15, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.6 mm.
Where to verify it
A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.
This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.
⚑Report an errorHow we know this›
Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
Dates adjusted with the VIIRS detections inside the perimeter, which said 9 June 2023 to 18 June 2023. 269 Suomi-NPP VIIRS detections on those dates.
Compared with CONAFOR: 3,895 official ha against 4,774 ha of perimeter; they agree within 25%.
Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.
The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.