Skip to content
worldfires
ID · Indonesia · –

Gorontalo Utara fire, 13 September 2026 Gorontalo Utara

Out · last detection

The fire started on in Gorontalo Utara, Indonesia, and satellites saw it burning for 13 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,801 hectares from heat detections, spread across a single municipality.

Number 400 in Indonesia in 2026, of 997.

GWIS near-real-time perimeter, from the layer that changed in October 2025: this fire is not compared with fires from earlier years, because since then the GWIS layer gives more and larger perimeters.

Compare with…

Suggestions: Gorontalo Utara · 2026

Burnt area
2,801ha
GWIS perimeter (Copernicus)
Duration
13days
13 Sept 2026 – 25 Sept 2026
Municipalities hit
1
regencies
Started on
13 Sept
2026
Heat detections
96
in a single hotspot: 51 MW
Danger at start
47
Very high · FWI index
Average daily power
52MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 13 Sept25 Sept
25 Sept 2026

How it evolved, day by day

14 Sept 2026 · 74 MW · 2 15 Sept 2026 · 88 MW · 16 16 Sept 2026 · 173 MW · 26 17 Sept 2026 · 2 MW · 1 18 Sept 2026 · 33 MW · 8 19 Sept 2026 · 120 MW · 26 20 Sept 2026 · 9 MW · 5 21 Sept 2026 · 15 MW · 10 22 Sept 2026 · 2 MW · 1 25 Sept 2026 · 1 MW · 1
14 Sept 16 Sept 18 Sept 20 Sept 22 Sept

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
62km/h · peak gust
28%lowest humidity

It had gone 52 days without rain (1 mm or more) when it started.

This area had burned before

4% of the perimeter overlaps earlier fires recorded since 2016: 122 ha in 2018.

How big is it?

10 km
It burned the equivalent of 1.8% of the area of London (28 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Gorontalo Utara where it started
    2,820 ha reached on 14 Sept
    1.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area3.3 ha
Residents≈ 700

Inside the perimeter there were about 3.3 hectares of built-up land and about 700 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
13 Sept 34.3 °C 36 % 45 km/h 0.0 mm Very high 47
14 Sept 34.0 °C 30 % 48 km/h 0.0 mm Extreme 54
15 Sept 33.4 °C 34 % 54 km/h 0.0 mm Extreme 57
16 Sept 33.7 °C 34 % 62 km/h 0.0 mm Extreme 61
17 Sept 33.9 °C 32 % 50 km/h 0.0 mm Extreme 55
18 Sept 34.4 °C 34 % 45 km/h 0.0 mm Extreme 51
19 Sept 35.2 °C 28 % 38 km/h 0.0 mm Very high 45
20 Sept 35.1 °C 35 % 37 km/h 0.0 mm Very high 43
21 Sept 35.2 °C 33 % 36 km/h 0.0 mm Very high 43
22 Sept 35.3 °C 33 % 36 km/h 0.0 mm Very high 42
23 Sept 35.5 °C 36 % 35 km/h 0.0 mm High 35
24 Sept 34.9 °C 39 % 31 km/h 0.1 mm High 37
25 Sept 35.4 °C 38 % 34 km/h 0.3 mm High 37
26 Sept after 35.4 °C 36 % 35 km/h 0.0 mm Very high 38
27 Sept after 35.4 °C 36 % 34 km/h 0.0 mm High 37
28 Sept after 35.6 °C 33 % 36 km/h 0.0 mm Very high 43
29 Sept after 35.6 °C 33 % 34 km/h 0.0 mm High 34
30 Sept after 35.6 °C 33 % 36 km/h 0.0 mm High 38
1 Oct after 35.1 °C 31 % 42 km/h 0.0 mm Very high 47
2 Oct after 35.1 °C 36 % 37 km/h 0.0 mm High 38
3 Oct after 35.0 °C 34 % 41 km/h 0.0 mm Very high 44
4 Oct after 34.9 °C 34 % 41 km/h 0.0 mm Very high 43
5 Oct after 35.1 °C 28 % 48 km/h 0.0 mm Extreme 53

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 6 Sept 2026
After · 2 Oct 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 22 September 2026 the air beside the fire reached 34 µg/m³ of PM2.5. That day averaged 26: 1.7 times the WHO daily guideline (15).

PM2.5 peak34 µg/m³
Days over the guideline9 days
PM1040 µg/m³
Optical depth0.69
11 Sept15 Sept19 Sept23 Sept
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 96Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Indonesia

Frequently asked questions

How long did the Gorontalo Utara fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 13 September 2026 to 25 September 2026 (13 days). The perimeter dates it from 13 September 2026 to 23 September 2026.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,801 hectares (28.0 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Gorontalo Utara (2,820 ha, 1.6 %).
What was the weather like?
During the fire the temperature reached 35.5 °C, humidity dropped to 28 % and gusts hit 62 km/h. The fire danger index (FWI) reached 61, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Indonesia (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 112 · Emergency number and official warnings

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 112.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 13 September 2026 to 23 September 2026. 96 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.