Feshi fire, 14 June 2020 Feshi

Out · last detection 20 Jun 2020, 11:46 UTC

The fire started on 14 June 2020 in Feshi, Democratic Republic of the Congo, and satellites saw it burning for 6 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 5,103 hectares from heat detections, spread across a single municipality.

It is the 201th largest in Kwango since 2016 (of 219 with a page). Number 156 in Democratic Republic of the Congo in 2020, of 165.

Compare with…
Burnt area
5,103ha
GWIS perimeter (Copernicus)
Duration
6days
14 Jun 2020 – 19 Jun 2020
Municipalities hit
1
territories
Started on
14 Jun
2020
Heat detections
198
in a single hotspot: 94 MW
Danger at start
24
High · FWI index
Average daily power
541MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 14 Jun19 Jun
20 Jun 2020

How it evolved, day by day

14 Jun 2020 · 302 MW · 9 15 Jun 2020 · 2,052 MW · 85 16 Jun 2020 · 1,211 MW · 61 17 Jun 2020 · 85 MW · 7 18 Jun 2020 · 16 MW · 4 19 Jun 2020 · 117 MW · 4 20 Jun 2020 · 7 MW · 1
14 Jun 15 Jun 16 Jun 17 Jun 18 Jun 19 Jun 20 Jun

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

30°high
38km/h · peak gust
22%lowest humidity

It had gone 31 days without rain (1 mm or more) when it started.

This area had burned before

57% of the perimeter overlaps earlier fires recorded since 2016: 1,156 ha in 2016, 844 ha in 2017, 1,316 ha in 2018, 1,384 ha in 2019. Part of it burned more than once, so the yearly figures add up to more than the 2,887 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 3.2% of the area of London (51 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Feshi where it started
    5,135 ha reached on 9 Jun
    0.3 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
14 Jun 30.1 °C 32 % 26 km/h 0.0 mm High 24
15 Jun 29.9 °C 29 % 32 km/h 0.0 mm High 28
16 Jun 29.6 °C 29 % 32 km/h 0.0 mm High 28
17 Jun 30.3 °C 22 % 34 km/h 0.0 mm High 34
18 Jun 28.7 °C 27 % 38 km/h 0.0 mm High 36
19 Jun 28.8 °C 28 % 30 km/h 0.0 mm High 33
20 Jun after 30.0 °C 25 % 19 km/h 0.0 mm High 32
21 Jun after 30.9 °C 23 % 26 km/h 0.0 mm High 33
22 Jun after 30.2 °C 23 % 19 km/h 0.0 mm High 33
23 Jun after 30.3 °C 26 % 24 km/h 0.0 mm High 32
24 Jun after 30.8 °C 29 % 33 km/h 0.0 mm High 35
25 Jun after 31.4 °C 26 % 25 km/h 0.0 mm High 34
26 Jun after 30.5 °C 22 % 30 km/h 0.0 mm High 34
27 Jun after 28.8 °C 38 % 19 km/h 0.0 mm High 29
28 Jun after 30.3 °C 34 % 30 km/h 0.0 mm High 32
29 Jun after 29.6 °C 36 % 27 km/h 0.0 mm High 30

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 7 Jun 2020
After · 26 Jun 2020

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 198Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Democratic Republic of the Congo ›

Frequently asked questions

How long did the Feshi fire last?
GWIS (Copernicus) dates it between 14 June 2020 and 19 June 2020: 6 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 5,103 hectares (51.0 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Feshi (5,135 ha, 0.3 %).
What was the weather like?
During the fire the temperature reached 30.3 °C, humidity dropped to 22 % and gusts hit 38 km/h. The fire danger index (FWI) reached 36, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Democratic Republic of the Congo (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 198 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.