Feshi fire, 16 June 2019 Feshi
The fire started on 16 June 2019 in Feshi, Congo - Kinshasa, and satellites saw it burning for 10 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 6,265 hectares from heat detections, spread across a single municipality.
It is the 116th largest in Kwango since 2016 (of 219 with a page). Number 74 in Congo - Kinshasa in 2019, of 115.
- Burnt area
- 6,265ha
- GWIS perimeter (Copernicus)
- Duration
- 10days
- 16 Jun 2019 – 25 Jun 2019
- Municipalities hit
- 1
- territories
- Started on
- 16 Jun
- 2019
- Heat detections
- 194
- in a single hotspot: 125 MW
- Danger at start
- 25
- High · FWI index
- Energy released
- 3.8GW
- sum of detected power
Where it burned
How it evolved, day by day
Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.
The weather it burned in
It had gone 15 days without rain (1 mm or more) when it started.
This area had burned before
57% of the perimeter overlaps earlier fires recorded since 2016: 1,092 ha in 2016, 1,924 ha in 2017, 2,235 ha in 2018. Part of it burned more than once, so the yearly figures add up to more than the 3,587 ha that had burned before.
What happened to each town
-
Feshi where it started6,302 ha reached on 10 Jun0.3 %
Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.
The weather day by day
ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.
Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)
| Day | High | Min. humidity | Peak gust | Rain | Danger (FWI) |
|---|---|---|---|---|---|
| 16 Jun | 30.2 °C | 30 % | 17 km/h | 0.0 mm | High 25 |
| 17 Jun | 30.9 °C | 30 % | 19 km/h | 0.0 mm | High 25 |
| 18 Jun | 31.5 °C | 30 % | 19 km/h | 0.0 mm | High 26 |
| 19 Jun | 31.9 °C | 25 % | 18 km/h | 0.0 mm | High 26 |
| 20 Jun | 31.9 °C | 22 % | 23 km/h | 0.0 mm | High 28 |
| 21 Jun | 31.3 °C | 28 % | 26 km/h | 0.0 mm | High 29 |
| 22 Jun | 30.8 °C | 30 % | 26 km/h | 0.0 mm | High 30 |
| 23 Jun | 28.5 °C | 37 % | 22 km/h | 0.0 mm | High 25 |
| 24 Jun | 30.6 °C | 31 % | 21 km/h | 0.0 mm | High 28 |
| 25 Jun | 30.3 °C | 28 % | 18 km/h | 0.0 mm | High 26 |
| 26 Jun after | 28.8 °C | 37 % | 23 km/h | 0.0 mm | High 27 |
| 27 Jun after | 30.6 °C | 33 % | 18 km/h | 0.0 mm | High 28 |
| 28 Jun after | 30.4 °C | 37 % | 26 km/h | 0.0 mm | High 28 |
| 29 Jun after | 29.0 °C | 49 % | 32 km/h | 0.3 mm | High 22 |
| 30 Jun after | 29.6 °C | 48 % | 27 km/h | 0.0 mm | High 22 |
| 1 Jul after | 31.4 °C | 28 % | 19 km/h | 0.0 mm | High 28 |
| 2 Jul after | 31.5 °C | 26 % | 24 km/h | 0.0 mm | High 29 |
| 3 Jul after | 30.1 °C | 39 % | 17 km/h | 0.0 mm | High 28 |
| 4 Jul after | 32.7 °C | 21 % | 29 km/h | 0.0 mm | High 34 |
| 5 Jul after | 30.6 °C | 25 % | 25 km/h | 0.0 mm | High 33 |
Before and after, from space
Drag the line to compare the same ground before the fire and after it.
If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.
Detections table · 194Every satellite heat detection, one by one, with time, satellite, power and coordinates.
| Date and time | Satellite | FRP (MW) | Lat | Lon |
|---|
Other fires nearby
Frequently asked questions
- How long did the Feshi fire last?
- GWIS (Copernicus) dates it between 16 June 2019 and 25 June 2019: 10 days between the first and last heat detection of the perimeter.
- How much area did it burn?
- The perimeter GWIS (Copernicus) rebuilt from heat detections is 6,265 hectares (62.6 km²). It is an estimate: official national figures may differ.
- Which municipalities burned?
- The fire only entered Feshi (6,302 ha, 0.3 %).
- What was the weather like?
- During the fire the temperature reached 31.9 °C, humidity dropped to 22 % and gusts hit 26 km/h. The fire danger index (FWI) reached 30, class High.
- Where does this data come from?
- From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Congo - Kinshasa (geoBoundaries). It is not an official report.
Where to verify it
A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.
Satellite cross-check
Does something look wrong on this page?
This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.
Report an error
Where this data comes from
The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.