Skip to content
worldfires
CF · Central African Republic · –

Fafa Boungou fire, 5 February 2019 Fafa Boungou, Lady Gbawi, Ndenga

Out · last detection 22 Feb 2019, 11:25 UTC

The fire started on 5 February 2019 in Fafa Boungou, Central African Republic, and satellites saw it burning for 18 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 7,270 hectares from heat detections, spread across 3 municipalities.

It is the 7th largest in Ouham since 2016 (of 19 with a page). Number 28 in Central African Republic in 2019, of 64.

Burnt area
7,270ha
GWIS perimeter (Copernicus)
Duration
18days
5 Feb 2019 – 22 Feb 2019
Municipalities hit
3
sub-prefectures
Started on
5 Feb
2019
Heat detections
297
in a single hotspot: 115 MW
Danger at start
51
Extreme · FWI index
Average daily power
278MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 5 Feb22 Feb
22 Feb 2019

How it evolved, day by day

5 Feb 2019 · 5 MW · 2 6 Feb 2019 · 112 MW · 9 7 Feb 2019 · 188 MW · 15 9 Feb 2019 · 4 MW · 1 12 Feb 2019 · 48 MW · 7 14 Feb 2019 · 389 MW · 31 15 Feb 2019 · 2,092 MW · 124 16 Feb 2019 · 267 MW · 44 17 Feb 2019 · 190 MW · 11 18 Feb 2019 · 127 MW · 18 19 Feb 2019 · 179 MW · 10 20 Feb 2019 · 62 MW · 2 21 Feb 2019 · 226 MW · 22 22 Feb 2019 · 4 MW · 1
5 Feb 9 Feb 15 Feb 18 Feb 21 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

39°high
40km/h · peak gust
10%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started. Rain came after the fire: 1.2 mm on 24 Feb.

This area had burned before

47% of the perimeter overlaps earlier fires recorded since 2016: 3,515 ha in 2016.

How big is it?

10 km
It burned the equivalent of 4.6% of the area of London (73 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Fafa Boungou where it started
    4,717 ha reached on 5 Feb
    0.6 %
  2. 2,319 ha reached on 6 Feb
    0.9 %
  3. 286 ha reached on 18 Feb
    0.1 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area< 0.1 ha
Residents< 20

Inside the perimeter there was no noticeable built-up land and almost nobody lived there (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with 60 days without rain: 30 % of the area in Central African Republic

Day High Min. humidity Peak gust Rain Danger (FWI)
5 Feb 36.4 °C 16 % 32 km/h 0.0 mm Extreme 51
6 Feb 35.2 °C 12 % 26 km/h 0.0 mm Extreme 57
7 Feb 34.8 °C 10 % 32 km/h 0.0 mm Extreme 63
8 Feb 34.5 °C 12 % 26 km/h 0.0 mm Extreme 61
9 Feb 36.2 °C 12 % 35 km/h 0.0 mm Very extreme 71
10 Feb 37.9 °C 14 % 36 km/h 0.0 mm Extreme 70
11 Feb 37.0 °C 18 % 33 km/h 0.0 mm Extreme 68
12 Feb 37.3 °C 16 % 22 km/h 0.0 mm Extreme 56
13 Feb 36.6 °C 14 % 36 km/h 0.0 mm Extreme 69
14 Feb 36.5 °C 13 % 28 km/h 0.0 mm Extreme 57
15 Feb 35.9 °C 12 % 36 km/h 0.0 mm Extreme 70
16 Feb 35.3 °C 13 % 36 km/h 0.0 mm Extreme 69
17 Feb 36.2 °C 17 % 32 km/h 0.0 mm Extreme 62
18 Feb 37.4 °C 14 % 31 km/h 0.0 mm Extreme 66
19 Feb 37.4 °C 15 % 37 km/h 0.0 mm Extreme 70
20 Feb 37.2 °C 13 % 31 km/h 0.0 mm Extreme 64
21 Feb 38.8 °C 11 % 40 km/h 0.0 mm Very extreme 80
22 Feb 37.6 °C 13 % 28 km/h 0.0 mm Extreme 53
23 Feb after 35.6 °C 33 % 41 km/h 0.0 mm Extreme 52
24 Feb after 36.3 °C 36 % 41 km/h 1.2 mm Very high 46

Its twins: fires that started in the same weather

It started with an FWI of 50.9, a minimum humidity of 16% and more than two months without rain. Fires in the area that started in weather like this since 2016: 19.

FWI at the start 50.9
Minimum humidity 16 %
Days without rain 60+
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Vassako fire, January 2021
36,459 ha 34 days FWI 50.6 Min. humidity 16 % 170 km away, in 2021

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

12 days
median duration
6,487 ha
median area
26 %
went past 10,000 ha
—
rain at the end (median; 0 of 19 had it)

It burned an area similar to its twins (7,270 ha against a median of 6,487 ha) and lasted 18 days, against 12 days.

In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

1.2 mmfirst rain
24 Feb2 days after it ended
40km/h · max. gust

It was considered over on 22 Feb, and on 24 Feb 1.2 mm fell. We do not know whether the rain or the firefighters put it out. None of its 19 twins had rain when they ended.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 29 Jan 2019
After · 1 Mar 2019

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 297Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Central African Republic

Frequently asked questions

How long did the Fafa Boungou fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 5 February 2019 to 22 February 2019 (18 days). The perimeter dates it from 12 February 2019 to 21 February 2019.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 7,270 hectares (72.7 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 3 municipalities: Fafa Boungou (4,717 ha, 0.6 %); Lady Gbawi (2,319 ha, 0.9 %); Ndenga (286 ha, 0.1 %).
What was the weather like?
During the fire the temperature reached 38.8 °C, humidity dropped to 10 % and gusts hit 40 km/h. The fire danger index (FWI) reached 80, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Central African Republic (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 19. Their median duration was 12 days and their median area 6,487 ha; 26 % went past 10,000 ha. In none of them did 1 mm fall in the ten days after the end: they all went out without rain.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 12 February 2019 to 21 February 2019. 297 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.