Skip to content
worldfires
ET · Ethiopia · –

Enemorina Eaner fire, January 2025 Enemorina Eaner, Sekoru

Out · last detection

The fire started on in Enemorina Eaner, Ethiopia, and satellites saw it burning for 17 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,020 hectares from heat detections, spread across 2 municipalities.

It is number 65 by size of the 161 fires with a page that started in SNNPR since 2016. Number 40 in Ethiopia in 2025, of 93.

Burnt area
3,020ha
GWIS perimeter (Copernicus)
Duration
17days
16 Jan 2025 – 1 Feb 2025
Municipalities hit
2
districts
Started on
16 Jan
2025
Heat detections
94
in a single hotspot: 63 MW
Danger at start
28
High · FWI index
Average daily power
145MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 16 Jan1 Feb
1 Feb 2025

How it evolved, day by day

16 Jan 2025 · 1 MW · 1 18 Jan 2025 · 2 MW · 1 21 Jan 2025 · 489 MW · 35 22 Jan 2025 · 383 MW · 19 23 Jan 2025 · 48 MW · 9 25 Jan 2025 · 276 MW · 19 27 Jan 2025 · 48 MW · 2 28 Jan 2025 · 4 MW · 1 1 Feb 2025 · 55 MW · 7
16 Jan 21 Jan 23 Jan 27 Jan 1 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

32°high
28km/h · peak gust
19%lowest humidity

It had gone 3 days without rain (1 mm or more) when it started.

This area had burned before

17% of the perimeter overlaps earlier fires recorded since 2016: 515 ha in 2023.

How big is it?

10 km
It burned the equivalent of 1.9% of the area of London (30 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Enemorina Eaner where it started
    3,008 ha reached on 16 Jan
    3.6 %
  2. 32 ha reached on 22 Jan
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents≈ 20

Inside the perimeter there were about 0.07 hectares of built-up land and about 20 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
16 Jan 32.4 °C 28 % 25 km/h 0.0 mm High 28
17 Jan 31.5 °C 26 % 28 km/h 0.0 mm High 30
18 Jan 32.2 °C 20 % 26 km/h 0.0 mm High 34
19 Jan 32.3 °C 20 % 25 km/h 0.0 mm High 38
20 Jan 32.1 °C 20 % 28 km/h 0.0 mm Very high 39
21 Jan 32.3 °C 21 % 28 km/h 0.0 mm Very high 40
22 Jan 30.0 °C 19 % 25 km/h 0.0 mm Very high 39
23 Jan 31.7 °C 26 % 24 km/h 0.0 mm Very high 41
24 Jan 28.3 °C 32 % 27 km/h 0.0 mm Very high 39
25 Jan 30.0 °C 43 % 22 km/h 0.1 mm High 30
26 Jan 29.3 °C 46 % 20 km/h 0.3 mm High 29
27 Jan 27.9 °C 43 % 16 km/h 0.1 mm High 22
28 Jan 31.5 °C 37 % 23 km/h 0.0 mm High 28
29 Jan 26.9 °C 45 % 16 km/h 0.3 mm High 24
30 Jan 30.8 °C 42 % 20 km/h 0.0 mm High 24
31 Jan 28.2 °C 36 % 28 km/h 0.0 mm High 28
1 Feb 31.3 °C 32 % 24 km/h 0.0 mm High 31
2 Feb after 28.3 °C 33 % 23 km/h 0.0 mm High 31
3 Feb after 30.9 °C 38 % 30 km/h 0.1 mm High 32
4 Feb after 31.1 °C 26 % 26 km/h 0.0 mm High 31
5 Feb after 32.0 °C 23 % 25 km/h 0.0 mm High 37
6 Feb after 31.4 °C 24 % 24 km/h 0.0 mm High 38
7 Feb after 31.8 °C 21 % 24 km/h 0.0 mm High 35
8 Feb after 30.3 °C 25 % 32 km/h 0.0 mm Very high 39
9 Feb after 32.4 °C 30 % 24 km/h 0.0 mm High 38
10 Feb after 30.8 °C 32 % 23 km/h 0.0 mm High 34
11 Feb after 30.4 °C 32 % 21 km/h 0.0 mm High 32

Its twins: fires that started in the same weather

It started with an FWI of 28.2, a minimum humidity of 28% and 3 days without rain. Fires in the area that started in weather like this since 2016: 23.

FWI at the start 28.2
Minimum humidity 28 %
Days without rain 3
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Decha fire, December 2016
19,025 ha 28 days FWI 29.4 Min. humidity 28 % 201 km away, in 2016

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

14 days
median duration
2,932 ha
median area
100 %
went past 1,000 ha
3.6 mm
rain at the end (median; 7 of 23 had it)

It burned an area similar to its twins (3,020 ha against a median of 2,932 ha) and lasted 17 days, against 14 days.

In 16 of 23, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 3.6 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
28km/h · max. gust

It was considered over on 1 Feb, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 7 of 23, with a median of 3.6 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 9 Jan 2025
After · 8 Feb 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 25 January 2025 the air beside the fire reached 99 µg/m³ of PM2.5. That day averaged 68: 4.5 times the WHO daily guideline (15).

PM2.5 peak99 µg/m³
Days over the guideline10 days
PM10105 µg/m³
Optical depth0.74
19 Jan21 Jan23 Jan25 Jan27 Jan
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 94Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ethiopia

Frequently asked questions

How long did the Enemorina Eaner fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 16 January 2025 to 1 February 2025 (17 days). The perimeter dates it from 21 January 2025 to 25 January 2025.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,020 hectares (30.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Enemorina Eaner (3,008 ha, 3.6 %); Sekoru (32 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 32.4 °C, humidity dropped to 19 % and gusts hit 28 km/h. The fire danger index (FWI) reached 41, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ethiopia (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 23. Their median duration was 14 days and their median area 2,932 ha; 100 % went past 1,000 ha. In 16 of 23, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 3.6 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 2 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 25 January 2025 → 1 February 2025.
  2. Start date: 21 January 2025 → 16 January 2025.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 21 January 2025 to 25 January 2025. 94 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.