Skip to content
worldfires
GN · Guinea · →

Douako fire, 24 January 2026 Douako

Out · last detection 31 Jan 2026, 14:23 UTC

The fire started on 24 January 2026 in Douako, Guinea, and satellites saw it burning for 8 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,957 hectares from heat detections, spread across a single municipality.

It is the 70th largest in Kankan since 2016 (of 388 with a page). Number 59 in Guinea in 2026, of 269.

The power measured by the satellite is low (23.2 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
3,957ha
GWIS perimeter (Copernicus)
Duration
8days
24 Jan 2026 – 31 Jan 2026
Municipalities hit
1
sub-prefectures
Started on
24 Jan
2026
Heat detections
83
in a single hotspot: 23 MW
Danger at start
32
High · FWI index
Energy released
395MW
sum of detected power

Where it burned

31 Jan 2026
HOTSPOTS BY DAY 24 Jan31 Jan

How it evolved, day by day

24252627283031

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
35km/h · peak gust
12%lowest humidity

It had gone 16 days without rain (1 mm or more) when it started.

This area had burned before

96% of the perimeter overlaps earlier fires recorded since 2016: 2,244 ha in 2016, 1,688 ha in 2017, 660 ha in 2018, 2,383 ha in 2019, 1,269 ha in 2020, 1,122 ha in 2021, 423 ha in 2022, 1,316 ha in 2023, 1,689 ha in 2024. Part of it burned more than once, so the yearly figures add up to more than the 3,784 ha that had burned before.

What happened to each town

  1. Douako where it started
    3,983 ha reached on 18 Jan
    1.4 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
24 Jan 33.3 °C 17 % 30 km/h 0.0 mm High 32
25 Jan 32.3 °C 17 % 35 km/h 0.0 mm High 35
26 Jan 33.3 °C 18 % 30 km/h 0.0 mm High 35
27 Jan 34.2 °C 15 % 29 km/h 0.0 mm High 35
28 Jan 34.3 °C 13 % 24 km/h 0.0 mm High 35
29 Jan 34.6 °C 12 % 23 km/h 0.0 mm High 36
30 Jan 35.2 °C 15 % 24 km/h 0.0 mm High 37
31 Jan 35.7 °C 16 % 21 km/h 0.0 mm Very high 38
1 Feb after 34.8 °C 24 % 26 km/h 0.0 mm High 36
2 Feb after 36.0 °C 22 % 24 km/h 0.0 mm High 37
3 Feb after 33.7 °C 28 % 24 km/h 0.0 mm High 35
4 Feb after 31.2 °C 38 % 17 km/h 0.1 mm High 27
5 Feb after 34.9 °C 19 % 36 km/h 0.0 mm Very high 38
6 Feb after 35.4 °C 15 % 38 km/h 0.0 mm Very high 42
7 Feb after 36.4 °C 10 % 31 km/h 0.0 mm Very high 45
8 Feb after 36.1 °C 10 % 25 km/h 0.0 mm Very high 43
9 Feb after 35.7 °C 9 % 32 km/h 0.0 mm Very high 46
10 Feb after 36.4 °C 11 % 25 km/h 0.0 mm Very high 44

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 17 Jan 2026
After · 7 Feb 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 28 January 2026 the air beside the fire reached 100 µg/m³ of PM2.5. That day averaged 71: 4.7 times the WHO daily guideline (15).

PM2.5 peak100 µg/m³
Days over the guideline13 days
PM10189 µg/m³
Optical depth0.68
22232425262728293031123
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 83Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Guinea ›

Frequently asked questions

How long did the Douako fire last?
GWIS (Copernicus) dates it between 24 January 2026 and 31 January 2026: 8 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,957 hectares (39.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Douako (3,983 ha, 1.4 %).
What was the weather like?
During the fire the temperature reached 35.7 °C, humidity dropped to 12 % and gusts hit 35 km/h. The fire danger index (FWI) reached 38, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Guinea (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.