Skip to content
worldfires
CD · Congo - Kinshasa · →

Demba fire, August 2020 Demba

Out · last detection 20 Aug 2020, 23:46 UTC

The fire started on 15 August 2020 in Demba, Congo - Kinshasa, and satellites saw it burning for 6 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 7,543 hectares from heat detections, spread across a single municipality.

It is the 42th largest in Central Kasai since 2016 (of 84 with a page). Number 71 in Congo - Kinshasa in 2020, of 165.

Burnt area
7,543ha
GWIS perimeter (Copernicus)
Duration
6days
15 Aug 2020 – 20 Aug 2020
Municipalities hit
1
territories
Started on
15 Aug
2020
Heat detections
236
in a single hotspot: 32 MW
Danger at start
25
High · FWI index
Energy released
1.1GW
sum of detected power

Where it burned

20 Aug 2020
HOTSPOTS BY DAY 15 Aug20 Aug

How it evolved, day by day

151617181920

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

34°high
27km/h · peak gust
39%lowest humidity

It had gone 32 days without rain (1 mm or more) when it started. Rain came after the fire: 3.1 mm on 21 Aug.

This area had burned before

1% of the perimeter overlaps earlier fires recorded since 2016: 110 ha in 2016.

What happened to each town

  1. Demba where it started
    7,595 ha reached on 8 Aug
    0.8 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
15 Aug 31.3 °C 48 % 22 km/h 0.0 mm High 25
16 Aug 33.2 °C 39 % 19 km/h 0.0 mm High 27
17 Aug 33.6 °C 44 % 25 km/h 0.0 mm High 28
18 Aug 32.1 °C 51 % 23 km/h 0.0 mm High 26
19 Aug 33.7 °C 44 % 27 km/h 5.1 mm Low 7
20 Aug 30.4 °C 60 % 19 km/h 13.9 mm Very low 1
21 Aug after 30.8 °C 56 % 25 km/h 3.1 mm Very low 2

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 8 Aug 2020
After · 27 Aug 2020

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 236Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Congo - Kinshasa ›

Frequently asked questions

How long did the Demba fire last?
GWIS (Copernicus) dates it between 15 August 2020 and 20 August 2020: 6 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 7,543 hectares (75.4 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Demba (7,595 ha, 0.8 %).
What was the weather like?
During the fire the temperature reached 33.7 °C, humidity dropped to 39 % and gusts hit 27 km/h. The fire danger index (FWI) reached 28, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Congo - Kinshasa (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.