Skip to content
worldfires
LA · Laos · →

Dakcheung fire, 23 March 2026 Dakcheung

Out · last detection 7 Apr 2026, 05:21 UTC

The fire started on 23 March 2026 in Dakcheung, Laos, and satellites saw it burning for 16 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 9,216 hectares from heat detections, spread across a single municipality.

It is the 2th largest in Xekong since 2016 (of 22 with a page). Number 42 in Laos in 2026, of 308.

Compare with…
Burnt area
9,216ha
GWIS perimeter (Copernicus)
Duration
16days
23 Mar 2026 – 7 Apr 2026
Municipalities hit
1
districts
Started on
23 Mar
2026
Heat detections
227
in a single hotspot: 307 MW
Danger at start
6
Low · FWI index
Average daily power
386MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 23 Mar7 Apr
7 Apr 2026

How it evolved, day by day

23 Mar 2026 · 100 MW · 9 24 Mar 2026 · 1,816 MW · 59 25 Mar 2026 · 1,717 MW · 52 26 Mar 2026 · 446 MW · 20 27 Mar 2026 · 853 MW · 29 28 Mar 2026 · 147 MW · 12 29 Mar 2026 · 25 MW · 3 30 Mar 2026 · 276 MW · 13 31 Mar 2026 · 20 MW · 2 1 Apr 2026 · 43 MW · 1 2 Apr 2026 · 68 MW · 10 3 Apr 2026 · 39 MW · 5 4 Apr 2026 · 40 MW · 5 5 Apr 2026 · 15 MW · 4 7 Apr 2026 · 181 MW · 3
23 Mar 24 Mar 26 Mar 29 Mar 1 Apr 4 Apr

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

30°high
43km/h · peak gust
30%lowest humidity

It had gone 2 days without rain (1 mm or more) when it started. Rain came after the fire: 2.1 mm on 14 Apr.

This area had burned before

60% of the perimeter overlaps earlier fires recorded since 2016: 1,220 ha in 2021, 1,293 ha in 2023, 3,953 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 5,503 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 5.8% of the area of London (92 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Dakcheung where it started
    9,268 ha reached on 23 Mar
    3.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area4.5 ha
Residents≈ 1,200

Inside the perimeter there were about 4.5 hectares of built-up land and about 1,200 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
23 Mar 26.7 °C 50 % 21 km/h 0.6 mm Low 6
24 Mar 27.8 °C 45 % 26 km/h 0.0 mm Low 8
25 Mar 29.5 °C 37 % 27 km/h 0.0 mm Low 10
26 Mar 29.9 °C 37 % 25 km/h 0.0 mm Low 11
27 Mar 30.1 °C 36 % 24 km/h 0.1 mm Low 11
28 Mar 29.2 °C 38 % 26 km/h 0.0 mm Moderate 12
29 Mar 29.7 °C 33 % 28 km/h 0.0 mm Moderate 13
30 Mar 30.5 °C 30 % 29 km/h 0.0 mm Moderate 15
31 Mar 30.3 °C 30 % 33 km/h 0.0 mm Moderate 16
1 Apr 29.8 °C 36 % 26 km/h 0.0 mm Moderate 16
2 Apr 29.0 °C 40 % 29 km/h 0.0 mm Moderate 16
3 Apr 30.1 °C 36 % 34 km/h 0.0 mm Moderate 18
4 Apr 28.1 °C 42 % 38 km/h 0.1 mm Moderate 18
5 Apr 29.0 °C 41 % 38 km/h 0.0 mm Moderate 18
6 Apr 30.1 °C 36 % 40 km/h 0.1 mm Moderate 19
7 Apr 29.9 °C 36 % 43 km/h 0.0 mm Moderate 20
8 Apr after 31.6 °C 32 % 33 km/h 0.0 mm Moderate 20
9 Apr after 30.0 °C 38 % 35 km/h 0.0 mm Moderate 21
10 Apr after 29.2 °C 43 % 38 km/h 0.0 mm Moderate 20
11 Apr after 28.9 °C 43 % 39 km/h 0.1 mm Moderate 20
12 Apr after 30.0 °C 40 % 38 km/h 0.1 mm Moderate 21
13 Apr after 29.6 °C 42 % 36 km/h 0.1 mm Moderate 21
14 Apr after 29.5 °C 48 % 24 km/h 2.1 mm Low 5

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 16 Mar 2026
After · 14 Apr 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 30 March 2026 the air beside the fire reached 91 µg/m³ of PM2.5. That day averaged 62: 4.1 times the WHO daily guideline (15).

PM2.5 peak91 µg/m³
Days over the guideline21 days
PM1096 µg/m³
Optical depth1.14
212223242526272829303112345678910
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 227Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Laos ›

Frequently asked questions

How long did the Dakcheung fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 23 March 2026 to 7 April 2026 (16 days). The perimeter dates it from 23 March 2026 to 31 March 2026.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 9,216 hectares (92.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Dakcheung (9,268 ha, 3.6 %).
What was the weather like?
During the fire the temperature reached 30.5 °C, humidity dropped to 30 % and gusts hit 43 km/h. The fire danger index (FWI) reached 20, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Laos (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 23 March 2026 to 31 March 2026. 227 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.