Skip to content
worldfires
MX · Mexico · –

Coyuca de Catalán fire, 24 April 2022 Coyuca de Catalán, Ajuchitlán del Progreso

Out · last detection 11 May 2022, 19:42 UTC

The fire started on 24 April 2022 in Coyuca de Catalán, Mexico, and satellites saw it burning for 19 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 8,282 hectares from heat detections, spread across 2 municipalities.

It is the 44th largest in Guerrero since 2016 (of 582 with a page). Number 13 in Mexico in 2022, of 232.

The power measured by the satellite is low (25.8 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
8,282ha
GWIS perimeter (Copernicus)
Duration
19days
24 Apr 2022 – 12 May 2022
Municipalities hit
2
municipalities
Started on
24 Apr
2022
Heat detections
297
in a single hotspot: 26 MW
Danger at start
34
High · FWI index
Average daily power
91MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 24 Apr12 May
11 May 2022

How it evolved, day by day

24 Apr 2022 · 16 MW · 3 25 Apr 2022 · 147 MW · 16 26 Apr 2022 · 49 MW · 21 27 Apr 2022 · 214 MW · 42 28 Apr 2022 · 111 MW · 17 29 Apr 2022 · 5 MW · 2 30 Apr 2022 · 17 MW · 3 2 May 2022 · 145 MW · 27 3 May 2022 · 13 MW · 3 4 May 2022 · 76 MW · 25 5 May 2022 · 184 MW · 41 6 May 2022 · 68 MW · 24 7 May 2022 · 23 MW · 13 8 May 2022 · 133 MW · 23 9 May 2022 · 85 MW · 20 10 May 2022 · 56 MW · 5 11 May 2022 · 201 MW · 12
24 Apr 27 Apr 3 May 7 May 11 May

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

34°high
41km/h · peak gust
14%lowest humidity

It had gone 14 days without rain (1 mm or more) when it started.

This area had burned before

95% of the perimeter overlaps earlier fires recorded since 2016: 1,182 ha in 2016, 3,933 ha in 2017, 1,685 ha in 2018, 6,640 ha in 2019, 4,652 ha in 2020, 1,226 ha in 2021. Part of it burned more than once, so the yearly figures add up to more than the 7,896 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 5.2% of the area of London (83 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Coyuca de Catalán where it started
    4,894 ha reached on 24 Apr
    1.4 %
  2. 3,624 ha reached on 2 May
    1.8 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2020
Built-up area1.0 ha
Residents≈ 100

Inside the perimeter there were about 1.0 hectares of built-up land and about 100 residents (GHSL 2020, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

Official record

Several official records match this area

According to CONAFOR, 2 fires started inside this perimeter on these dates, totalling 5,183 ha (the satellite measured 8,282 ha). The two figures differ a lot, so these may not be exactly the same fire: take them as nearby records.

CONAFOR records each fire that started at a different time or place separately; the satellite sees a single burned area, so this page groups them together. The numbers on the map show where each one started.

When each one burned

1 1,078 ha 2 4,105 ha
25 Apr3 May
arson
  1. 1 Coyuca de Catalán Cuajilote Grande y Anexos 25 April 2022 1,078 ha · extinguished on 1 May 2022 · cause: arson
  2. 2 Ajuchitlán del Progreso El Espiritu-Cuajilote Grande y Anexos 1 May 2022 4,105 ha · extinguished on 4 May 2022 · cause: arson

Total according to CONAFOR: 5,183 ha, 63 % of the 8,282 ha in the satellite perimeter.

CONAFOR (Comisión Nacional Forestal), estadística de incendios forestales en datos.gob.mx (CC BY 4.0). This is the agency’s consolidated statistic: it measures the area in its own way, which is why it can differ from the satellite.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
24 Apr 31.2 °C 23 % 38 km/h 0.0 mm High 34
25 Apr 31.6 °C 20 % 37 km/h 0.0 mm High 34
26 Apr 29.6 °C 23 % 30 km/h 0.3 mm High 37
27 Apr 31.3 °C 19 % 34 km/h 0.1 mm Very high 38
28 Apr 32.4 °C 18 % 35 km/h 0.0 mm High 36
29 Apr 32.0 °C 20 % 41 km/h 0.0 mm High 35
30 Apr 31.9 °C 14 % 38 km/h 0.0 mm Very high 39
1 May 31.9 °C 19 % 36 km/h 0.0 mm Very high 42
2 May 31.8 °C 22 % 40 km/h 0.0 mm Very high 42
3 May 31.4 °C 19 % 32 km/h 0.0 mm Very high 41
4 May 32.5 °C 18 % 32 km/h 0.0 mm Very high 40
5 May 32.6 °C 19 % 36 km/h 0.0 mm Very high 41
6 May 32.2 °C 23 % 37 km/h 0.0 mm Very high 40
7 May 32.2 °C 27 % 33 km/h 0.0 mm High 37
8 May 31.9 °C 26 % 36 km/h 0.3 mm High 38
9 May 32.4 °C 27 % 34 km/h 0.0 mm Very high 38
10 May 34.1 °C 23 % 31 km/h 0.0 mm Very high 40
11 May 32.5 °C 25 % 31 km/h 0.0 mm High 38
12 May 32.1 °C 23 % 37 km/h 0.0 mm Very high 38
13 May after 30.2 °C 31 % 32 km/h 0.3 mm High 34
14 May after 30.1 °C 33 % 31 km/h 0.6 mm High 33
15 May after 30.4 °C 28 % 31 km/h 0.5 mm High 30
16 May after 31.8 °C 23 % 37 km/h 0.0 mm High 33
17 May after 31.3 °C 24 % 40 km/h 0.0 mm High 36
18 May after 32.2 °C 19 % 37 km/h 0.0 mm Very high 39
19 May after 32.7 °C 15 % 37 km/h 0.0 mm Very high 44
20 May after 31.4 °C 19 % 34 km/h 0.0 mm Very high 44
21 May after 31.5 °C 25 % 36 km/h 0.1 mm Very high 39
22 May after 30.6 °C 32 % 34 km/h 0.2 mm High 34

Its twins: fires that started in the same weather

It started with an FWI of 33.7, a minimum humidity of 23% and 14 days without rain. Fires in the area that started in weather like this since 2016: 24.

FWI at the start 33.7
Minimum humidity 23 %
Days without rain 14
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

San Miguel Totolapan fire, April 2021
1,838 ha 12 days FWI 32.8 Min. humidity 23 % 61 km away, in 2021

First rain (1 mm or more) after it ended: 15.6 mm on 9 May.

What happened to them

11 days
median duration
2,784 ha
median area
100 %
went past 1,000 ha
2.4 mm
rain at the end (median; 15 of 24 had it)

It was 3.0 times larger than the median of its twins and lasted 19 days, against 11 days.

Only 1 of its 24 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 9 of 24, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.4 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
41km/h · max. gust

It was considered over on 12 May, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 15 of 24, with a median of 2.4 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 17 Apr 2022
After · 19 May 2022

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 297Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Mexico

Frequently asked questions

How long did the Coyuca de Catalán fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 24 April 2022 to 12 May 2022 (19 days). The perimeter dates it from 25 April 2022 to 11 May 2022.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 8,282 hectares (82.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Coyuca de Catalán (4,894 ha, 1.4 %); Ajuchitlán del Progreso (3,624 ha, 1.8 %).
What was the weather like?
During the fire the temperature reached 34.1 °C, humidity dropped to 14 % and gusts hit 41 km/h. The fire danger index (FWI) reached 42, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mexico (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 24. Their median duration was 11 days and their median area 2,784 ha; 100 % went past 1,000 ha. Only 1 of its 24 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 9 of 24, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 2.4 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 911 · Emergency number and official warnings

Satellite cross-check

History of this page · 1 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Area: 8,475 → 8,282 ha.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 911.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery; 3 polygons grouped in this page.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 25 April 2022 to 11 May 2022. 297 Suomi-NPP VIIRS detections on those dates.
  • Compared with CONAFOR: 5,183 official ha against 8,282 ha of perimeter; similar, but with reservations.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2020, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.