Skip to content
worldfires
KH · Cambodia · →

Chhaeb fire, 18 January 2026 Chhaeb

Out · last detection 26 Jan 2026, 18:24 UTC

The fire started on 18 January 2026 in Chhaeb, Cambodia, and satellites saw it burning for 9 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,456 hectares from heat detections, spread across a single municipality.

It is the 59th largest in Preah Vihear since 2016 (of 97 with a page). Number 85 in Cambodia in 2026, of 120.

Compare with…
Burnt area
2,456ha
GWIS perimeter (Copernicus)
Duration
9days
18 Jan 2026 – 26 Jan 2026
Municipalities hit
1
districts
Started on
18 Jan
2026
Heat detections
86
in a single hotspot: 61 MW
Danger at start
22
High · FWI index
Average daily power
47MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 18 Jan26 Jan
26 Jan 2026

How it evolved, day by day

18 Jan 2026 · 13 MW · 3 20 Jan 2026 · 50 MW · 4 21 Jan 2026 · 125 MW · 23 22 Jan 2026 · 19 MW · 2 23 Jan 2026 · 21 MW · 4 24 Jan 2026 · 100 MW · 10 25 Jan 2026 · 7 MW · 3 26 Jan 2026 · 40 MW · 5
18 Jan 21 Jan 23 Jan 25 Jan

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

32°high
34km/h · peak gust
30%lowest humidity

It had gone 26 days without rain (1 mm or more) when it started.

This area had burned before

71% of the perimeter overlaps earlier fires recorded since 2016: 170 ha in 2017, 286 ha in 2022, 1,005 ha in 2024, 1,397 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 1,739 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.6% of the area of London (25 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Chhaeb where it started
    2,469 ha
    1.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
18 Jan 32.0 °C 45 % 19 km/h 0.0 mm High 22
19 Jan 32.4 °C 36 % 30 km/h 0.0 mm High 22
20 Jan 32.1 °C 38 % 24 km/h 0.0 mm High 23
21 Jan 31.7 °C 34 % 30 km/h 0.0 mm High 25
22 Jan 31.5 °C 30 % 31 km/h 0.0 mm High 27
23 Jan 31.0 °C 35 % 34 km/h 0.0 mm High 27
24 Jan 31.7 °C 34 % 32 km/h 0.0 mm High 27
25 Jan 31.7 °C 35 % 29 km/h 0.0 mm High 26
26 Jan 31.8 °C 36 % 25 km/h 0.0 mm High 27
27 Jan after 32.1 °C 35 % 24 km/h 0.0 mm High 26
28 Jan after 32.0 °C 36 % 27 km/h 0.0 mm High 27
29 Jan after 32.6 °C 36 % 30 km/h 0.0 mm High 28
30 Jan after 33.1 °C 35 % 24 km/h 0.0 mm High 28
31 Jan after 33.0 °C 35 % 23 km/h 0.0 mm High 27
1 Feb after 32.6 °C 30 % 31 km/h 0.0 mm High 28
2 Feb after 32.5 °C 34 % 36 km/h 0.0 mm High 31
3 Feb after 32.7 °C 39 % 36 km/h 0.0 mm High 30
4 Feb after 33.7 °C 35 % 27 km/h 0.0 mm High 28
5 Feb after 34.9 °C 34 % 21 km/h 0.0 mm High 28

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 11 Jan 2026
After · 2 Feb 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 25 January 2026 the air beside the fire reached 54 µg/m³ of PM2.5. That day averaged 31: 2.0 times the WHO daily guideline (15).

PM2.5 peak54 µg/m³
Days over the guideline12 days
PM1055 µg/m³
Optical depth0.55
1617181920212223242526272829
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 86Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Cambodia ›

Frequently asked questions

How long did the Chhaeb fire last?
GWIS (Copernicus) dates it between 18 January 2026 and 26 January 2026: 9 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,456 hectares (24.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Chhaeb (2,469 ha, 1.0 %).
What was the weather like?
During the fire the temperature reached 32.4 °C, humidity dropped to 30 % and gusts hit 34 km/h. The fire danger index (FWI) reached 27, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Cambodia (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 86 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 International (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.