Skip to content
worldfires
CD · Congo - Kinshasa · →

Bumba fire, 22 February 2026 Bumba, Aketi

Out · last detection 9 Mar 2026, 12:45 UTC

The fire started on 22 February 2026 in Bumba, Congo - Kinshasa, and satellites saw it burning for 18 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 39,883 hectares from heat detections, spread across 2 municipalities.

It is the 4th largest in Mongala since 2016 (of 27 with a page). Number 27 in Congo - Kinshasa in 2026, of 523.

Burnt area
39,883ha
GWIS perimeter (Copernicus)
Duration
18days
22 Feb 2026 – 11 Mar 2026
Municipalities hit
2
territories
Started on
22 Feb
2026
Heat detections
846
in a single hotspot: 227 MW
Danger at start
4
Very low · FWI index
Energy released
14.1GW
sum of detected power

Where it burned

9 Mar 2026
HOTSPOTS BY DAY 22 Feb11 Mar

How it evolved, day by day

222324252627282346789

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

38°high
29km/h · peak gust
21%lowest humidity

It had gone 0 days without rain (1 mm or more) when it started. Rain came after the fire: 2.1 mm on 12 Mar.

This area had burned before

60% of the perimeter overlaps earlier fires recorded since 2016: 1,675 ha in 2016, 2,090 ha in 2017, 1,034 ha in 2018, 1,240 ha in 2019, 7,850 ha in 2020, 2,653 ha in 2021, 1,913 ha in 2022, 5,252 ha in 2023, 15,275 ha in 2024, 1,159 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 23,965 ha that had burned before.

What happened to each town

  1. Bumba where it started
    24,455 ha reached on 22 Feb
    1.5 %
  2. 15,689 ha reached on 24 Feb
    0.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
22 Feb 30.9 °C 51 % 23 km/h 0.0 mm Very low 4
23 Feb 32.2 °C 49 % 24 km/h 0.6 mm Low 7
24 Feb 33.3 °C 41 % 21 km/h 0.4 mm Moderate 11
25 Feb 33.9 °C 35 % 22 km/h 0.1 mm Moderate 13
26 Feb 34.4 °C 23 % 24 km/h 0.0 mm Moderate 17
27 Feb 34.5 °C 27 % 26 km/h 0.0 mm Moderate 20
28 Feb 34.2 °C 31 % 28 km/h 0.0 mm Moderate 20
1 Mar 34.7 °C 31 % 22 km/h 0.0 mm Moderate 20
2 Mar 32.4 °C 49 % 25 km/h 1.0 mm Low 10
3 Mar 28.9 °C 50 % 29 km/h 0.0 mm Moderate 11
4 Mar 32.2 °C 41 % 17 km/h 0.4 mm Moderate 15
5 Mar 32.1 °C 37 % 20 km/h 0.0 mm Moderate 16
6 Mar 33.5 °C 37 % 21 km/h 0.0 mm Moderate 18
7 Mar 34.6 °C 34 % 25 km/h 0.0 mm Moderate 20
8 Mar 36.6 °C 27 % 29 km/h 0.0 mm High 24
9 Mar 37.7 °C 21 % 27 km/h 0.0 mm High 28
10 Mar 33.7 °C 35 % 24 km/h 0.0 mm High 26
11 Mar 34.6 °C 36 % 26 km/h 0.0 mm High 26
12 Mar after 32.0 °C 45 % 28 km/h 2.1 mm Low 10

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 15 Feb 2026
After · 18 Mar 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 2 March 2026 the air beside the fire reached 103 µg/m³ of PM2.5. That day averaged 68: 4.5 times the WHO daily guideline (15).

PM2.5 peak103 µg/m³
Days over the guideline23 days
PM10166 µg/m³
Optical depth1.36
2021222324252627281234567891011121314
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 846Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Congo - Kinshasa ›

Frequently asked questions

How long did the Bumba fire last?
GWIS (Copernicus) dates it between 22 February 2026 and 11 March 2026: 18 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 39,883 hectares (398.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Bumba (24,455 ha, 1.5 %); Aketi (15,689 ha, 0.6 %).
What was the weather like?
During the fire the temperature reached 37.7 °C, humidity dropped to 21 % and gusts hit 29 km/h. The fire danger index (FWI) reached 28, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Congo - Kinshasa (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.