Skip to content
worldfires
GN · Guinea · –

Bouliwel fire, February 2024 Bouliwel

Out · last detection 26 Feb 2024, 14:36 UTC

The fire started on 23 February 2024 in Bouliwel, Guinea, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,984 hectares from heat detections, spread across a single municipality.

It is the 16th largest in Mamou since 2016 (of 53 with a page). Number 36 in Guinea in 2024, of 118.

Burnt area
2,984ha
GWIS perimeter (Copernicus)
Duration
4days
23 Feb 2024 – 26 Feb 2024
Municipalities hit
1
sub-prefectures
Started on
23 Feb
2024
Heat detections
93
in a single hotspot: 31 MW
Danger at start
42
Very high · FWI index
Average daily power
244MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 23 Feb26 Feb
26 Feb 2024

How it evolved, day by day

23 Feb 2024 · 75 MW · 9 24 Feb 2024 · 14 MW · 6 25 Feb 2024 · 824 MW · 58 26 Feb 2024 · 64 MW · 20
23 Feb 24 Feb 25 Feb 26 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

36°high
30km/h · peak gust
15%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

97% of the perimeter overlaps earlier fires recorded since 2016: 817 ha in 2016, 1,816 ha in 2017, 27 ha in 2018, 2,059 ha in 2019, 709 ha in 2021, 2,123 ha in 2022. Part of it burned more than once, so the yearly figures add up to more than the 2,883 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.9% of the area of London (30 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Bouliwel where it started
    3,002 ha reached on 23 Feb
    5.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area5.9 ha
Residents≈ 600

Inside the perimeter there were about 5.9 hectares of built-up land and about 600 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Started with 60 days without rain: 34 % of the area in Guinea

Day High Min. humidity Peak gust Rain Danger (FWI)
23 Feb 35.3 °C 15 % 30 km/h 0.0 mm Very high 42
24 Feb 36.3 °C 15 % 20 km/h 0.0 mm Very high 40
25 Feb 35.5 °C 17 % 24 km/h 0.0 mm Very high 41
26 Feb 35.1 °C 27 % 22 km/h 0.0 mm High 38
27 Feb after 35.5 °C 27 % 23 km/h 0.0 mm Very high 39
28 Feb after 36.5 °C 25 % 24 km/h 0.0 mm Very high 40
29 Feb after 37.7 °C 20 % 23 km/h 0.0 mm High 37
1 Mar after 35.8 °C 29 % 23 km/h 0.0 mm Very high 38
2 Mar after 36.0 °C 31 % 20 km/h 0.0 mm High 36
3 Mar after 37.5 °C 13 % 30 km/h 0.0 mm Very high 45
4 Mar after 35.6 °C 25 % 24 km/h 0.0 mm Very high 41
5 Mar after 37.0 °C 12 % 21 km/h 0.0 mm Very high 44
6 Mar after 38.6 °C 19 % 18 km/h 0.0 mm Very high 45
7 Mar after 36.5 °C 22 % 21 km/h 0.0 mm Very high 44

Its twins: fires that started in the same weather

It started with an FWI of 42.4, a minimum humidity of 15% and more than two months without rain. Fires in the area that started in weather like this since 2016: 61.

FWI at the start 42.4
Minimum humidity 15 %
Days without rain 60+
this fire chosen twins rest of the area
Almost identicalSimilar

Outlines of the closest twins

Bouliwel fire, February 2017
2,115 ha 5 days FWI 42.7 Min. humidity 15 % 7 km away, in 2017

First rain (1 mm or more) after it ended: none in the following ten days.

What happened to them

8 days
median duration
1,835 ha
median area
100 %
went past 1,000 ha
1.9 mm
rain at the end (median; 12 of 61 had it)

It was 1.6 times larger than the median of its twins and lasted 4 days, against 8 days.

Only 5 of its 61 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 49 of 61, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.9 mm.

This is a bank of analogues: it shows what usually happens, not what will happen. With fewer than 15 twins we give no figures. How we calculate it

How it ended

—first rain
—no rain in ten days
30km/h · max. gust

It was considered over on 26 Feb, and not even 1 mm fell in the following ten days: it went out without rain. Twins with rain when they ended: 12 of 61, with a median of 1.9 mm.

Weather on this page: Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

How a twin is chosen

  • Same area: fires that have already ended, less than 250 km from this one, since 2016.
  • Same start: we compare the FWI on the first day, the minimum humidity that day and the run of days without rain before it. The slider sets how much they may differ.
  • Only pages with final weather data (ERA5 reanalysis) calculated in the same way as this fire’s; agricultural and grass burns and pages with data under review are left out.
  • Fires burning at the same time as this one (a week before or after) are left out: they share the same spell of weather and do not count as a precedent.
  • They are sorted by similarity, and the outlines of the first five are drawn.

How we calculate it

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 16 Feb 2024
After · 4 Mar 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 26 February 2024 the air beside the fire reached 85 µg/m³ of PM2.5. That day averaged 70: 4.7 times the WHO daily guideline (15).

PM2.5 peak85 µg/m³
Days over the guideline9 days
PM10196 µg/m³
Optical depth1.12
21 Feb23 Feb25 Feb27 Feb29 Feb
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 93Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Guinea

Frequently asked questions

How long did the Bouliwel fire last?
GWIS (Copernicus) dates it between 23 February 2024 and 26 February 2024: 4 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,984 hectares (29.8 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Bouliwel (3,002 ha, 5.6 %).
What was the weather like?
During the fire the temperature reached 36.3 °C, humidity dropped to 15 % and gusts hit 30 km/h. The fire danger index (FWI) reached 42, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Guinea (geoBoundaries). It is not an official report.
How did the fires that started in similar weather in this area end?
Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 61. Their median duration was 8 days and their median area 1,835 ha; 100 % went past 1,000 ha. Only 5 of its 61 twins burned more. The weather on the first day does not explain everything: the wind in the following days, the fuel and the firefighting also count. In 49 of 61, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 1.9 mm.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 93 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.