Skip to content
worldfires
CD · Congo - Kinshasa · →

Bondo fire, February 2026 Bondo

Out · last detection 9 Mar 2026, 11:05 UTC

The fire started on 22 February 2026 in Bondo, Congo - Kinshasa, and satellites saw it burning for 19 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 8,506 hectares from heat detections, spread across a single municipality.

It is the 14th largest in Lower Uele since 2016 (of 48 with a page). Number 230 in Congo - Kinshasa in 2026, of 523.

Burnt area
8,506ha
GWIS perimeter (Copernicus)
Duration
19days
22 Feb 2026 – 12 Mar 2026
Municipalities hit
1
territories
Started on
22 Feb
2026
Heat detections
212
in a single hotspot: 146 MW
Danger at start
15
Moderate · FWI index
Energy released
2.6GW
sum of detected power

Where it burned

9 Mar 2026
HOTSPOTS BY DAY 22 Feb12 Mar

How it evolved, day by day

22232425262728123456789

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

38°high
30km/h · peak gust
15%lowest humidity

It had gone 0 days without rain (1 mm or more) when it started. Rain came after the fire: 1.6 mm on 20 Mar.

This area had burned before

67% of the perimeter overlaps earlier fires recorded since 2016: 853 ha in 2016, 320 ha in 2017, 3,354 ha in 2019, 23 ha in 2020, 4,675 ha in 2021, 3,476 ha in 2022, 1,734 ha in 2023, 2,607 ha in 2024, 1,821 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 5,702 ha that had burned before.

What happened to each town

  1. Bondo where it started
    8,558 ha reached on 22 Feb
    0.2 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
22 Feb 33.1 °C 39 % 23 km/h 0.0 mm Moderate 15
23 Feb 32.3 °C 43 % 24 km/h 0.2 mm Moderate 16
24 Feb 34.3 °C 30 % 19 km/h 0.0 mm Moderate 21
25 Feb 35.1 °C 15 % 18 km/h 0.0 mm High 29
26 Feb 34.9 °C 16 % 27 km/h 0.0 mm High 32
27 Feb 34.8 °C 18 % 26 km/h 0.0 mm High 32
28 Feb 34.7 °C 24 % 26 km/h 0.0 mm High 31
1 Mar 34.3 °C 27 % 17 km/h 0.0 mm High 30
2 Mar 32.5 °C 42 % 25 km/h 0.3 mm High 23
3 Mar 31.2 °C 35 % 27 km/h 0.6 mm Moderate 20
4 Mar 34.2 °C 23 % 20 km/h 0.0 mm High 30
5 Mar 32.8 °C 28 % 19 km/h 0.0 mm High 29
6 Mar 34.6 °C 28 % 27 km/h 0.0 mm High 30
7 Mar 36.2 °C 26 % 24 km/h 0.0 mm High 30
8 Mar 37.0 °C 16 % 27 km/h 0.0 mm High 35
9 Mar 37.7 °C 15 % 30 km/h 0.0 mm Very high 39
10 Mar 34.5 °C 25 % 23 km/h 0.0 mm High 36
11 Mar 35.3 °C 29 % 26 km/h 0.0 mm High 35
12 Mar 32.8 °C 41 % 28 km/h 1.8 mm Moderate 16
13 Mar after 35.6 °C 32 % 24 km/h 0.0 mm High 24
14 Mar after 36.4 °C 30 % 26 km/h 0.0 mm High 29
15 Mar after 30.7 °C 53 % 32 km/h 0.9 mm Moderate 17
16 Mar after 33.4 °C 39 % 27 km/h 0.2 mm High 22
17 Mar after 34.1 °C 37 % 30 km/h 0.1 mm High 25
18 Mar after 33.9 °C 37 % 32 km/h 0.9 mm High 23
19 Mar after 31.6 °C 47 % 19 km/h 0.3 mm High 22
20 Mar after 34.1 °C 40 % 25 km/h 1.6 mm Moderate 17

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 15 Feb 2026
After · 19 Mar 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 1 March 2026 the air beside the fire reached 77 µg/m³ of PM2.5. That day averaged 65: 4.3 times the WHO daily guideline (15).

PM2.5 peak77 µg/m³
Days over the guideline24 days
PM10117 µg/m³
Optical depth1.19
202122232425262728123456789101112131415
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 212Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Congo - Kinshasa ›

Frequently asked questions

How long did the Bondo fire last?
GWIS (Copernicus) dates it between 22 February 2026 and 12 March 2026: 19 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 8,506 hectares (85.1 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Bondo (8,558 ha, 0.2 %).
What was the weather like?
During the fire the temperature reached 37.7 °C, humidity dropped to 15 % and gusts hit 30 km/h. The fire danger index (FWI) reached 39, class Very high.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Congo - Kinshasa (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.