Skip to content
worldfires
MX · Mexico · →

Bocoyna fire, 30 May 2024 Bocoyna

Out · last detection 7 Jun 2024, 08:17 UTC

The fire started on 30 May 2024 in Bocoyna, Mexico, and satellites saw it burning for 9 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,862 hectares from heat detections, spread across a single municipality. According to CONAFOR, it was detected on 29 May 2024 and declared extinguished on 7 June 2024.

It is the 70th largest in Chihuahua since 2016 (of 234 with a page). Number 76 in Mexico in 2024, of 289.

Compare with…
Burnt area
3,862ha
GWIS perimeter (Copernicus)
Duration
9days
30 May 2024 – 7 Jun 2024
Municipalities hit
1
municipalities
Started on
30 May
2024
Heat detections
102
in a single hotspot: 305 MW
Danger at start
51
Extreme · FWI index
Average daily power
865MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 30 May7 Jun
7 Jun 2024

How it evolved, day by day

4 Jun 2024 · 1,853 MW · 29 5 Jun 2024 · 393 MW · 34 6 Jun 2024 · 1,203 MW · 35 7 Jun 2024 · 12 MW · 4
4 Jun 5 Jun 6 Jun 7 Jun

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

30°high
54km/h · peak gust
10%lowest humidity

It had gone 58 days without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

How big is it?

10 km
It burned the equivalent of 2.4% of the area of London (39 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Bocoyna where it started
    3,880 ha reached on 4 Jun
    1.4 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area0.32 ha
Residents≈ 20

Inside the perimeter there were about 0.32 hectares of built-up land and about 20 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

Official record

According to CONAFOR, this fire started on 29 May 2024 and burned 4,821 ha (the satellite measured 3,862 ha).

CONAFOR (Comisión Nacional Forestal), estadística de incendios forestales en datos.gob.mx (CC BY 4.0). This is the agency’s consolidated statistic: it measures the area in its own way, which is why it can differ from the satellite.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
30 May 27.3 °C 12 % 52 km/h 0.0 mm Extreme 51
31 May 29.0 °C 10 % 50 km/h 0.0 mm Extreme 54
1 Jun 28.3 °C 16 % 49 km/h 0.0 mm Extreme 52
2 Jun 28.5 °C 12 % 52 km/h 0.0 mm Extreme 54
3 Jun 28.3 °C 13 % 54 km/h 0.0 mm Extreme 56
4 Jun 27.7 °C 13 % 52 km/h 0.0 mm Extreme 54
5 Jun 30.4 °C 13 % 34 km/h 0.0 mm Very high 49
6 Jun 30.0 °C 14 % 41 km/h 0.0 mm Extreme 52
7 Jun 27.2 °C 20 % 36 km/h 0.0 mm Very high 43
8 Jun after 26.8 °C 18 % 45 km/h 0.3 mm Very high 48
9 Jun after 25.5 °C 21 % 44 km/h 0.1 mm Very high 44
10 Jun after 28.1 °C 21 % 30 km/h 0.0 mm Very high 42
11 Jun after 29.6 °C 18 % 33 km/h 0.0 mm Very high 42
12 Jun after 31.2 °C 20 % 33 km/h 0.0 mm Very high 40
13 Jun after 31.8 °C 16 % 43 km/h 0.0 mm Very high 48
14 Jun after 30.4 °C 22 % 32 km/h 0.0 mm Very high 45
15 Jun after 32.9 °C 19 % 36 km/h 0.3 mm Very high 45
16 Jun after 31.6 °C 22 % 43 km/h 0.6 mm Very high 40
17 Jun after 30.1 °C 19 % 54 km/h 0.0 mm Very high 49

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 23 May 2024
After · 14 Jun 2024

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 31 May 2024 the air beside the fire reached 64 µg/m³ of PM2.5. That day averaged 26: 1.7 times the WHO daily guideline (15).

PM2.5 peak64 µg/m³
Days over the guideline1 day
PM1092 µg/m³
Optical depth0.74
2829303112345678910
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 102Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Mexico ›

Frequently asked questions

How long did the Bocoyna fire last?
GWIS (Copernicus) dates it between 30 May 2024 and 7 June 2024: 9 days between the first and last heat detection of the perimeter. According to CONAFOR, it was detected on 29 May 2024 and declared extinguished on 7 June 2024.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,862 hectares (38.6 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Bocoyna (3,880 ha, 1.4 %).
What was the weather like?
During the fire the temperature reached 30.4 °C, humidity dropped to 10 % and gusts hit 54 km/h. The fire danger index (FWI) reached 56, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mexico (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 911 · Emergency number and official warnings ›

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 911.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery; 2 polygons grouped in this page.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 102 Suomi-NPP VIIRS detections on those dates.
  • Compared with CONAFOR: 4,821 official ha against 3,862 ha of perimeter; they agree within 25%.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.