Skip to content
worldfires
MX · Mexico · →

Balleza fire, May 2025 Balleza

Out · last detection 12 May 2025, 20:18 UTC

The fire started on 4 May 2025 in Balleza, Mexico, and satellites saw it burning for 9 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,714 hectares from heat detections, spread across a single municipality.

It is the 110th largest in Chihuahua since 2016 (of 234 with a page). Number 75 in Mexico in 2025, of 166.

Compare with…
Burnt area
2,714ha
GWIS perimeter (Copernicus)
Duration
9days
4 May 2025 – 12 May 2025
Municipalities hit
1
municipalities
Started on
4 May
2025
Heat detections
234
in a single hotspot: 504 MW
Danger at start
66
Extreme · FWI index
Average daily power
2.1GW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 4 May12 May
12 May 2025

How it evolved, day by day

5 May 2025 · 9,382 MW · 52 6 May 2025 · 2,213 MW · 84 7 May 2025 · 486 MW · 61 8 May 2025 · 222 MW · 29 9 May 2025 · 21 MW · 7 12 May 2025 · 4 MW · 1
5 May 6 May 7 May 8 May 9 May 12 May

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

25°high
88km/h · peak gust
7%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

10% of the perimeter overlaps earlier fires recorded since 2016: 281 ha in 2024.

How big is it?

10 km
It burned the equivalent of 1.7% of the area of London (27 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Balleza where it started
    2,723 ha reached on 5 May
    0.5 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area0.12 ha
Residents≈ 20

Inside the perimeter there were about 0.12 hectares of built-up land and about 20 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
5 May 18.1 °C 14 % 88 km/h 0.0 mm Extreme 66
6 May 18.3 °C 13 % 69 km/h 0.0 mm Extreme 55
7 May 22.7 °C 8 % 54 km/h 0.0 mm Very high 50
8 May 24.9 °C 7 % 48 km/h 0.0 mm Very high 50
9 May 23.2 °C 19 % 44 km/h 0.1 mm Very high 47
10 May 20.7 °C 23 % 41 km/h 0.7 mm High 32
11 May 23.8 °C 14 % 35 km/h 0.0 mm High 35
12 May 24.8 °C 19 % 46 km/h 0.5 mm Very high 40
13 May after 25.3 °C 15 % 56 km/h 0.0 mm Very high 47
14 May after 23.9 °C 10 % 61 km/h 0.0 mm Extreme 53
15 May after 23.6 °C 19 % 50 km/h 0.0 mm Very high 47
16 May after 23.9 °C 16 % 49 km/h 0.0 mm Very high 47
17 May after 24.9 °C 16 % 57 km/h 0.1 mm Very high 50
18 May after 23.5 °C 19 % 68 km/h 0.0 mm Extreme 54
19 May after 22.8 °C 13 % 70 km/h 0.0 mm Extreme 56
20 May after 26.9 °C 8 % 53 km/h 0.0 mm Extreme 53
21 May after 27.4 °C 8 % 53 km/h 0.0 mm Extreme 54
22 May after 28.5 °C 7 % 46 km/h 0.0 mm Extreme 55

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 27 Apr 2025
After · 19 May 2025

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 7 May 2025 the air beside the fire reached 25 µg/m³ of PM2.5, but no daily average passed the WHO guideline (15).

PM2.5 peak25 µg/m³
Days over the guideline0 days
PM1026 µg/m³
Optical depth0.25
3456789101112131415
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 234Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Mexico ›

Frequently asked questions

How long did the Balleza fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 4 May 2025 to 12 May 2025 (9 days). The perimeter dates it from 6 May 2025 to 9 May 2025.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,714 hectares (27.1 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Balleza (2,723 ha, 0.5 %).
What was the weather like?
During the fire the temperature reached 24.9 °C, humidity dropped to 7 % and gusts hit 88 km/h. The fire danger index (FWI) reached 66, class Extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Mexico (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 911 · Emergency number and official warnings ›

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 911.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 6 May 2025 to 9 May 2025. 234 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 4.0 (CC BY 4.0)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.