Skip to content
worldfires
CD · Democratic Republic of the Congo · →

Bafwasende fire, 15 February 2026 Bafwasende, Kisangani

Out · last detection 1 Mar 2026, 11:55 UTC

The fire started on 15 February 2026 in Bafwasende, Democratic Republic of the Congo, and satellites saw it burning for 15 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 20,526 hectares from heat detections, spread across 2 municipalities.

It is the 2th largest in Tshopo since 2016 (of 29 with a page). Number 63 in Democratic Republic of the Congo in 2026, of 523.

Compare with…
Burnt area
20,526ha
GWIS perimeter (Copernicus)
Duration
15days
15 Feb 2026 – 1 Mar 2026
Municipalities hit
2
territories
Started on
15 Feb
2026
Heat detections
280
in a single hotspot: 70 MW
Danger at start
8
Low · FWI index
Average daily power
222MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 15 Feb1 Mar
1 Mar 2026

How it evolved, day by day

15 Feb 2026 · 27 MW · 5 16 Feb 2026 · 125 MW · 9 17 Feb 2026 · 744 MW · 76 19 Feb 2026 · 33 MW · 3 20 Feb 2026 · 98 MW · 10 24 Feb 2026 · 343 MW · 53 25 Feb 2026 · 256 MW · 15 26 Feb 2026 · 519 MW · 64 27 Feb 2026 · 216 MW · 26 28 Feb 2026 · 76 MW · 15 1 Mar 2026 · 4 MW · 1
15 Feb 17 Feb 20 Feb 25 Feb 27 Feb 1 Mar

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

34°high
30km/h · peak gust
33%lowest humidity

It had gone 2 days without rain (1 mm or more) when it started. Rain came after the fire: 1.9 mm on 10 Mar.

This area had burned before

46% of the perimeter overlaps earlier fires recorded since 2016: 3,635 ha in 2018, 1,534 ha in 2019, 2,141 ha in 2020, 3,467 ha in 2021, 7,838 ha in 2022, 14,677 ha in 2023, 4,119 ha in 2024, 252 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 9,480 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 13% of the area of London (205 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Bafwasende where it started
    19,736 ha reached on 12 Feb
    0.4 %
  2. 929 ha reached on 19 Feb
    0.4 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area3.2 ha
Residents≈ 1,400

Inside the perimeter there were about 3.2 hectares of built-up land and about 1,400 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
12 Feb 33.0 °C 49 % 25 km/h 0.4 mm Low 8
13 Feb 30.1 °C 60 % 26 km/h 1.6 mm Very low 2
14 Feb 28.7 °C 63 % 28 km/h 6.7 mm Very low 0
15 Feb 32.5 °C 45 % 22 km/h 0.3 mm Very low 4
16 Feb 30.9 °C 54 % 16 km/h 0.4 mm Low 6
17 Feb 33.8 °C 44 % 24 km/h 0.5 mm Low 9
18 Feb 27.0 °C 67 % 22 km/h 5.9 mm Very low 0
19 Feb 32.0 °C 49 % 30 km/h 0.2 mm Very low 2
20 Feb 33.7 °C 49 % 22 km/h 0.6 mm Low 6
21 Feb 26.9 °C 71 % 29 km/h 5.5 mm Very low 0
22 Feb 27.3 °C 69 % 26 km/h 5.9 mm Very low 0
23 Feb 32.0 °C 51 % 19 km/h 0.2 mm Very low 1
24 Feb 32.2 °C 51 % 22 km/h 0.3 mm Very low 4
25 Feb 32.4 °C 51 % 18 km/h 0.3 mm Low 6
26 Feb 33.4 °C 35 % 23 km/h 0.0 mm Low 10
27 Feb 33.5 °C 33 % 24 km/h 0.0 mm Moderate 12
28 Feb 32.1 °C 43 % 29 km/h 0.0 mm Moderate 13
1 Mar 30.7 °C 54 % 28 km/h 0.2 mm Low 10
2 Mar after 30.9 °C 51 % 24 km/h 0.1 mm Low 10
3 Mar after 28.6 °C 54 % 35 km/h 0.3 mm Low 9
4 Mar after 31.9 °C 47 % 21 km/h 0.1 mm Low 10
5 Mar after 30.8 °C 46 % 24 km/h 0.1 mm Moderate 11
6 Mar after 32.0 °C 44 % 24 km/h 0.1 mm Moderate 13
7 Mar after 33.5 °C 39 % 23 km/h 0.0 mm Moderate 14
8 Mar after 35.7 °C 30 % 27 km/h 0.0 mm Moderate 18
9 Mar after 34.2 °C 38 % 25 km/h 0.0 mm Moderate 20
10 Mar after 30.5 °C 55 % 22 km/h 1.9 mm Very low 5

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 8 Feb 2026
After · 8 Mar 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 1 March 2026 the air beside the fire reached 67 µg/m³ of PM2.5. That day averaged 62: 4.1 times the WHO daily guideline (15).

PM2.5 peak67 µg/m³
Days over the guideline14 days
PM1095 µg/m³
Optical depth1.42
131415161718192021222324252627281234
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 280Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Democratic Republic of the Congo ›

Frequently asked questions

How long did the Bafwasende fire last?
GWIS (Copernicus) dates it between 15 February 2026 and 1 March 2026: 15 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 20,526 hectares (205.3 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Bafwasende (19,736 ha, 0.4 %); Kisangani (929 ha, 0.4 %).
What was the weather like?
During the fire the temperature reached 33.8 °C, humidity dropped to 33 % and gusts hit 30 km/h. The fire danger index (FWI) reached 13, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Democratic Republic of the Congo (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery; 2 polygons grouped in this page.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 280 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.