Skip to content
worldfires
ET · Ethiopia · →

Assosa fire, 20 January 2016 Assosa, Bambasi

Out · last detection 23 Jan 2016, 11:39 UTC

The fire started on 20 January 2016 in Assosa, Ethiopia, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 3,516 hectares from heat detections, spread across 2 municipalities.

It is the 237th largest in Beneshangul Gumu since 2016 (of 699 with a page). Number 110 in Ethiopia in 2016, of 309.

Burnt area
3,516ha
GWIS perimeter (Copernicus)
Duration
4days
20 Jan 2016 – 23 Jan 2016
Municipalities hit
2
districts
Started on
20 Jan
2016
Heat detections
119
in a single hotspot: 90 MW
Danger at start
28
High · FWI index
Energy released
794MW
sum of detected power

Where it burned

23 Jan 2016
HOTSPOTS BY DAY 20 Jan23 Jan

How it evolved, day by day

20212223

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

28°high
28km/h · peak gust
17%lowest humidity

It had gone 47 days without rain (1 mm or more) when it started.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

What happened to each town

  1. Assosa where it started
    2,790 ha reached on 20 Jan
    0.9 %
  2. 747 ha reached on 20 Jan
    0.6 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
20 Jan 27.8 °C 17 % 26 km/h 0.0 mm High 28
21 Jan 28.4 °C 21 % 21 km/h 0.0 mm High 28
22 Jan 28.3 °C 25 % 26 km/h 0.0 mm High 28
23 Jan 28.5 °C 22 % 28 km/h 0.0 mm High 30
24 Jan after 27.1 °C 24 % 30 km/h 0.0 mm High 31
25 Jan after 27.6 °C 21 % 31 km/h 0.0 mm High 33
26 Jan after 27.5 °C 26 % 29 km/h 0.0 mm High 31
27 Jan after 26.5 °C 23 % 35 km/h 0.0 mm High 34
28 Jan after 25.8 °C 22 % 31 km/h 0.0 mm High 33
29 Jan after 25.1 °C 21 % 29 km/h 0.0 mm High 32
30 Jan after 27.5 °C 21 % 26 km/h 0.0 mm High 30
31 Jan after 26.8 °C 22 % 24 km/h 0.0 mm High 31
1 Feb after 28.0 °C 18 % 30 km/h 0.0 mm High 33
2 Feb after 26.8 °C 21 % 31 km/h 0.0 mm High 34

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 13 Jan 2016
After · 30 Jan 2016

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

Detections table · 119Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ethiopia ›

Frequently asked questions

How long did the Assosa fire last?
GWIS (Copernicus) dates it between 20 January 2016 and 23 January 2016: 4 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 3,516 hectares (35.2 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: Assosa (2,790 ha, 0.9 %); Bambasi (747 ha, 0.6 %).
What was the weather like?
During the fire the temperature reached 28.5 °C, humidity dropped to 17 % and gusts hit 28 km/h. The fire danger index (FWI) reached 30, class High.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ethiopia (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.