Skip to content
worldfires
SD · Sudan · →

As Sunut fire, 3 March 2026 As Sunut, Al Lagowa

Out · last detection 9 Mar 2026, 11:07 UTC

The fire started on 3 March 2026 in As Sunut, Sudan, and satellites saw it burning for 10 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 9,112 hectares from heat detections, spread across 2 municipalities.

It is the 6th largest in West Kordofan since 2016 (of 181 with a page). Number 10 in Sudan in 2026, of 249.

Compare with…
Burnt area
9,112ha
GWIS perimeter (Copernicus)
Duration
10days
3 Mar 2026 – 12 Mar 2026
Municipalities hit
2
localities
Started on
3 Mar
2026
Heat detections
202
in a single hotspot: 36 MW
Danger at start
70
Extreme · FWI index
Average daily power
159MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 3 Mar12 Mar
9 Mar 2026

How it evolved, day by day

3 Mar 2026 · 24 MW · 5 4 Mar 2026 · 14 MW · 7 5 Mar 2026 · 316 MW · 39 6 Mar 2026 · 288 MW · 42 7 Mar 2026 · 177 MW · 30 8 Mar 2026 · 173 MW · 45 9 Mar 2026 · 121 MW · 34
3 Mar 4 Mar 5 Mar 6 Mar 7 Mar 8 Mar 9 Mar

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

38°high
50km/h · peak gust
7%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

88% of the perimeter overlaps earlier fires recorded since 2016: 1,280 ha in 2016, 1,072 ha in 2018, 1,695 ha in 2019, 1,292 ha in 2020, 2,198 ha in 2021, 2,220 ha in 2022, 5 ha in 2023, 2,881 ha in 2024, 1,389 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 8,008 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 5.8% of the area of London (91 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. As Sunut where it started
    9,139 ha reached on 3 Mar
    1.3 %
  2. 22 ha
    0.0 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area0.27 ha
Residents≈ 50

Inside the perimeter there were about 0.27 hectares of built-up land and about 50 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
3 Mar 29.3 °C 8 % 50 km/h 0.0 mm Extreme 70
4 Mar 29.8 °C 8 % 48 km/h 0.0 mm Extreme 69
5 Mar 32.2 °C 7 % 44 km/h 0.0 mm Extreme 65
6 Mar 34.1 °C 8 % 41 km/h 0.0 mm Extreme 63
7 Mar 34.8 °C 9 % 44 km/h 0.0 mm Extreme 66
8 Mar 34.5 °C 7 % 50 km/h 0.0 mm Very extreme 71
9 Mar 34.3 °C 7 % 49 km/h 0.0 mm Very extreme 71
10 Mar 34.5 °C 7 % 45 km/h 0.0 mm Extreme 68
11 Mar 35.9 °C 8 % 38 km/h 0.0 mm Extreme 62
12 Mar 37.9 °C 7 % 36 km/h 0.0 mm Extreme 62
13 Mar after 39.1 °C 6 % 32 km/h 0.0 mm Extreme 61
14 Mar after 40.5 °C 6 % 23 km/h 0.0 mm Extreme 57
15 Mar after 41.0 °C 8 % 30 km/h 0.0 mm Extreme 58
16 Mar after 38.0 °C 12 % 36 km/h 0.0 mm Extreme 58
17 Mar after 37.8 °C 14 % 22 km/h 0.0 mm Extreme 55
18 Mar after 37.2 °C 23 % 48 km/h 0.0 mm Extreme 59
19 Mar after 34.7 °C 27 % 30 km/h 0.0 mm Very high 43
20 Mar after 36.9 °C 9 % 35 km/h 0.0 mm Extreme 57
21 Mar after 36.4 °C 9 % 38 km/h 0.0 mm Extreme 60
22 Mar after 36.8 °C 21 % 29 km/h 0.0 mm Very high 48

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 24 Feb 2026
After · 19 Mar 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 15 March 2026 the air beside the fire reached 84 µg/m³ of PM2.5. That day averaged 51: 3.4 times the WHO daily guideline (15).

PM2.5 peak84 µg/m³
Days over the guideline13 days
PM10349 µg/m³
Optical depth0.55
123456789101112131415
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 202Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Sudan ›

Frequently asked questions

How long did the As Sunut fire last?
GWIS (Copernicus) dates it between 3 March 2026 and 12 March 2026: 10 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 9,112 hectares (91.1 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 2 municipalities: As Sunut (9,139 ha, 1.3 %); Al Lagowa (22 ha, 0.0 %).
What was the weather like?
During the fire the temperature reached 37.9 °C, humidity dropped to 7 % and gusts hit 50 km/h. The fire danger index (FWI) reached 71, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Sudan (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.

No changes since 24 October 2026.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 202 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.