Skip to content
worldfires
ET · Ethiopia · →

Akobo fire, 13 February 2023 Akobo

Out · last detection 22 Feb 2023, 11:32 UTC

The fire started on 13 February 2023 in Akobo, Ethiopia, and satellites saw it burning for 10 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,501 hectares from heat detections, spread across a single municipality.

It is the 433th largest in Gambela since 2016 (of 611 with a page). Number 68 in Ethiopia in 2023, of 101.

The power measured by the satellite is low (18.0 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Compare with…
Burnt area
2,501ha
GWIS perimeter (Copernicus)
Duration
10days
13 Feb 2023 – 22 Feb 2023
Municipalities hit
1
districts
Started on
13 Feb
2023
Heat detections
102
in a single hotspot: 18 MW
Danger at start
64
Extreme · FWI index
Average daily power
67MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 13 Feb22 Feb
22 Feb 2023

How it evolved, day by day

13 Feb 2023 · 25 MW · 3 15 Feb 2023 · 21 MW · 7 16 Feb 2023 · 66 MW · 24 17 Feb 2023 · 107 MW · 18 18 Feb 2023 · 158 MW · 35 19 Feb 2023 · 88 MW · 14 22 Feb 2023 · 2 MW · 1
13 Feb 15 Feb 16 Feb 17 Feb 18 Feb 19 Feb 22 Feb

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

39°high
50km/h · peak gust
15%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started.

This area had burned before

100% of the perimeter overlaps earlier fires recorded since 2016: 898 ha in 2016, 3,029 ha in 2017, 64 ha in 2018, 80 ha in 2019, 775 ha in 2020, 2,129 ha in 2021, 1,218 ha in 2022. Part of it burned more than once, so the yearly figures add up to more than the 2,517 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 1.6% of the area of London (25 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. Akobo where it started
    2,516 ha reached on 13 Feb
    1.2 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

People and buildings inside the perimeter

GHSL 2025
Built-up area< 0.1 ha
Residents≈ 50

Inside the perimeter there were about 0.00 hectares of built-up land and about 50 residents (GHSL 2025, satellite-based estimate).

This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned. The GHSL 2025 epoch is a projection made from 2020 and earlier data.

Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. human-settlement.emergency.copernicus.eu

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
15 Feb 39.2 °C 15 % 42 km/h 0.0 mm Extreme 64
16 Feb 36.7 °C 15 % 50 km/h 0.0 mm Very extreme 70
17 Feb 37.3 °C 16 % 41 km/h 0.0 mm Extreme 64
18 Feb 38.2 °C 16 % 38 km/h 0.0 mm Extreme 60
19 Feb 38.3 °C 15 % 35 km/h 0.0 mm Extreme 58
20 Feb 38.8 °C 15 % 26 km/h 0.0 mm Extreme 54
21 Feb 39.9 °C 17 % 35 km/h 0.0 mm Extreme 57
22 Feb 40.3 °C 14 % 31 km/h 0.0 mm Extreme 55
23 Feb after 40.8 °C 12 % 31 km/h 0.0 mm Extreme 60
24 Feb after 40.0 °C 9 % 20 km/h 0.0 mm Extreme 52
25 Feb after 39.2 °C 16 % 35 km/h 0.0 mm Extreme 59
26 Feb after 40.7 °C 17 % 22 km/h 0.0 mm Very high 49
27 Feb after 40.2 °C 19 % 36 km/h 0.0 mm Extreme 57
28 Feb after 38.9 °C 25 % 35 km/h 0.0 mm Extreme 57
1 Mar after 37.3 °C 26 % 46 km/h 0.0 mm Extreme 56

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 6 Feb 2023
After · 1 Mar 2023

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 22 February 2023 the air beside the fire reached 88 µg/m³ of PM2.5. That day averaged 55: 3.6 times the WHO daily guideline (15).

PM2.5 peak88 µg/m³
Days over the guideline10 days
PM10128 µg/m³
Optical depth1.34
13141516171819202122
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 102Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Ethiopia ›

Frequently asked questions

How long did the Akobo fire last?
According to the heat detections seen by satellite inside the perimeter, it burned from 13 February 2023 to 22 February 2023 (10 days). The perimeter dates it from 15 February 2023 to 19 February 2023.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,501 hectares (25.0 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Akobo (2,516 ha, 1.2 %).
What was the weather like?
During the fire the temperature reached 39.2 °C, humidity dropped to 15 % and gusts hit 50 km/h. The fire danger index (FWI) reached 70, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Ethiopia (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 2 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Last day with fire: 19 February 2023 → 22 February 2023.
  2. Start date: 15 February 2023 → 13 February 2023.

RSS Changes to this page

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
  • Dates adjusted with the VIIRS detections inside the perimeter, which said 15 February 2023 to 19 February 2023. 102 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
  • Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2025, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

How we build fire pages: methodology ›

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM3 (Open Data Commons Open Database License 1.0). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.