Skip to content
worldfires
PE · Peru · →

Abancay fire, July 2026 Abancay

Out · last detection 10 Jul 2026, 06:52 UTC

The fire started on 9 July 2026 in Abancay, Peru, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,491 hectares from heat detections, spread across a single municipality.

It is the 11th largest in Apurímac since 2016 (of 30 with a page). Number 41 in Peru in 2026, of 90.

The power measured by the satellite is low (14.5 MW in the strongest hotspot), more typical of grass or stubble burning, or a slow surface fire, than of a large crown fire.

Burnt area
1,491ha
GWIS perimeter (Copernicus)
Duration
4days
9 Jul 2026 – 12 Jul 2026
Municipalities hit
1
provinces
Started on
9 Jul
2026
Heat detections
11
in a single hotspot: 14 MW
Danger at start
0
Very low · FWI index
Energy released
48MW
sum of detected power

Where it burned

10 Jul 2026
HOTSPOTS BY DAY 9 Jul12 Jul

How it evolved, day by day

910

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

18°high
14km/h · peak gust
24%lowest humidity

It had gone one day without rain (1 mm or more) when it started. Rain came after the fire: 1.8 mm on 14 Jul.

This area had burned before

1% of the perimeter overlaps earlier fires recorded since 2016: 22 ha in 2020.

What happened to each town

  1. Abancay 13,299 inhabitants where it started
    1,498 ha reached on 9 Jul
    0.4 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
9 Jul 17.8 °C 32 % 13 km/h 3.5 mm Very low 0
10 Jul 15.6 °C 43 % 13 km/h 4.9 mm Very low 0
11 Jul 17.2 °C 24 % 12 km/h 0.3 mm Very low 1
12 Jul 15.6 °C 42 % 14 km/h 0.1 mm Very low 3
13 Jul after 15.4 °C 41 % 14 km/h 0.0 mm Very low 4
14 Jul after 16.9 °C 41 % 13 km/h 1.8 mm Very low 1

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 2 Jul 2026
After · 19 Jul 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 11 July 2026 the air beside the fire reached 33 µg/m³ of PM2.5. That day averaged 18: 1.2 times the WHO daily guideline (15).

PM2.5 peak33 µg/m³
Days over the guideline3 days
PM1036 µg/m³
Optical depth0.25
789101112131415
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 11Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Peru ›

Frequently asked questions

How long did the Abancay fire last?
GWIS (Copernicus) dates it between 9 July 2026 and 12 July 2026: 4 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,491 hectares (14.9 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Abancay (1,498 ha, 0.4 %).
What was the weather like?
During the fire the temperature reached 17.8 °C, humidity dropped to 24 % and gusts hit 14 km/h. The fire danger index (FWI) reached 3, class Very low.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Peru (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Emergency number: 116 · 105

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy. This is not an emergency service: if there is a fire now, call 116 · 105.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Creative Commons Attribution 3.0 Intergovernmental Organisations (CC BY 3.0 IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.