Skip to content
worldfires
BF · Burkina Faso · –

Seytenga fire, October 2026 Sampelga, Seytenga, Titabè

Out · last detection 31 Oct 2026, 01:41 UTC

The fire started on 17 October 2026 in Seytenga, Burkina Faso, and satellites saw it burning for 14 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 41,009 hectares from heat detections, spread across 4 municipalities.

Number 2 in Burkina Faso in 2026, of 448.

GWIS near-real-time perimeter, from the layer that changed in August 2025: this fire is not compared with fires from earlier years, because since then the GWIS layer gives more and larger perimeters.

Burnt area
41,009ha
GWIS perimeter (Copernicus)
Duration
14days
17 Oct 2026 – 30 Oct 2026
Municipalities hit
4
communes
Started on
17 Oct
2026
Heat detections
618
in a single hotspot: 49 MW
Danger at start
42
Very high · FWI index
Average daily power
284MW
detected power per day, on average

Where it burned

HOTSPOTS BY DAY 17 Oct30 Oct
31 Oct 2026

How it evolved, day by day

17 Oct 2026 · 347 MW · 36 18 Oct 2026 · 35 MW · 6 19 Oct 2026 · 371 MW · 20 20 Oct 2026 · 420 MW · 49 21 Oct 2026 · 339 MW · 49 22 Oct 2026 · 499 MW · 50 23 Oct 2026 · 278 MW · 39 24 Oct 2026 · 31 MW · 16 25 Oct 2026 · 201 MW · 40 26 Oct 2026 · 338 MW · 64 27 Oct 2026 · 485 MW · 87 28 Oct 2026 · 487 MW · 95 29 Oct 2026 · 423 MW · 65 30 Oct 2026 · 5 MW · 1 31 Oct 2026 · 1 MW · 1
17 Oct 22 Oct 26 Oct 29 Oct

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

Fire front film How it spread from one satellite pass to the next (88 passes) and with what wind. Watch the film

The weather it burned in

40°high
40km/h · peak gust
11%lowest humidity

It had gone 2 days without rain (1 mm or more) when it started.

This area had burned before

4% of the perimeter overlaps earlier fires recorded since 2016: 130 ha in 2023, 1,569 ha in 2025. Part of it burned more than once, so the yearly figures add up to more than the 1,549 ha that had burned before.

How big is it?

10 km
It burned the equivalent of 26% of the area of London (410 km² against 1,583 km²).

London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).

This compares size, not location: both shapes are at the same scale, north up, centred on each other.

What happened to each town

  1. 17,997 ha reached on 19 Oct
    33 %
  2. Seytenga where it started
    13,276 ha reached on 17 Oct
    16 %
  3. 11,364 ha reached on 26 Oct
    11 %
  4. 1,852 ha reached on 22 Oct
    0.7 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance runs from the point marking the centre of each area to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
17 Oct 40.5 °C 21 % 27 km/h 0.0 mm Very high 42
18 Oct 40.2 °C 21 % 26 km/h 0.0 mm High 36
19 Oct 39.7 °C 21 % 29 km/h 0.0 mm Very high 44
20 Oct 40.2 °C 16 % 37 km/h 0.0 mm Extreme 53
21 Oct 40.2 °C 15 % 32 km/h 0.0 mm Extreme 62
22 Oct 40.2 °C 12 % 38 km/h 0.0 mm Very extreme 73
23 Oct 39.6 °C 13 % 37 km/h 0.0 mm Very extreme 74
24 Oct 39.9 °C 11 % 22 km/h 0.0 mm Extreme 50
25 Oct 39.3 °C 17 % 18 km/h 0.0 mm Very high 47
26 Oct 39.2 °C 21 % 31 km/h 0.0 mm Extreme 61
27 Oct 39.1 °C 25 % 40 km/h 0.0 mm Extreme 58
28 Oct 39.0 °C 25 % 20 km/h 0.0 mm Very high 41
29 Oct 39.2 °C 22 % 24 km/h 0.0 mm Very high 50
30 Oct 40.3 °C 15 % 31 km/h 0.0 mm Extreme 67
31 Oct after 39.9 °C 14 % 26 km/h 0.0 mm Very high 49
1 Nov after 40.5 °C 11 % 24 km/h 0.0 mm Extreme 53
2 Nov after 41.6 °C 12 % 23 km/h 0.0 mm Extreme 54
3 Nov after 42.0 °C 17 % 29 km/h 0.0 mm Extreme 51
4 Nov after 41.3 °C 14 % 31 km/h 0.0 mm Extreme 61
5 Nov after 41.0 °C 11 % 32 km/h 0.0 mm Very extreme 75
6 Nov after 41.6 °C 9 % 29 km/h 0.0 mm Very extreme 76
7 Nov after 40.7 °C 10 % 23 km/h 0.0 mm Extreme 61
8 Nov after 40.6 °C 13 % 19 km/h 0.0 mm Extreme 57

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 10 Oct 2026
After · 6 Nov 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 17 October 2026 the air beside the fire reached 37 µg/m³ of PM2.5. That day averaged 31: 2.1 times the WHO daily guideline (15).

PM2.5 peak37 µg/m³
Days over the guideline3 days
PM10118 µg/m³
Optical depth0.47
151617
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 618Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Burkina Faso

Frequently asked questions

How long did the Seytenga fire last?
GWIS (Copernicus) dates it between 17 October 2026 and 30 October 2026: 14 days between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 41,009 hectares (410.1 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire entered 4 municipalities: Sampelga (17,997 ha, 33 %); Seytenga (13,276 ha, 16 %); Titabè (11,364 ha, 11 %); Dori (1,852 ha, 0.7 %).
Is the Seytenga fire still active?
No fire detections since 31 Oct 2026, 01:41 UTC. A lack of detections is not an official extinction.
What was the weather like?
During the fire the temperature reached 40.5 °C, humidity dropped to 11 % and gusts hit 40 km/h. The fire danger index (FWI) reached 74, class Very extreme.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Burkina Faso (OCHA COD-AB). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

History of this page · 7 Changes in area, dates, name, official record or merged pages, compared every night since 24 October 2026.
  1. Area: 43,825 → 41,009 ha.
  2. Last day with fire: 24 October 2026 → 30 October 2026.
  3. Area: 38,179 → 43,825 ha.
  4. Area: 32,252 → 38,179 ha.
  5. Area: 12,258 → 32,252 ha.
  6. The page “Seytenga, 20 October 2026” has been merged into this one: it was the same fire.
  7. The page “Sampelga, 26 October 2026” has been merged into this one: it was the same fire.

RSS Changes to this page With cross-checks and a citable version

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

How we know this
  • Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery; 6 polygons grouped in this page.
  • Dates from the perimeter: the VIIRS detections inside it did not change them. 618 Suomi-NPP VIIRS detections on those dates.
  • We have not matched this page with any official record.
  • Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

How we build fire pages: methodology

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from OCHA COD-AB (Institut Geographique Burkina (IGB)) (Creative Commons Attribution for Intergovernmental Organisations (CC BY-IGO)). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.