Skip to content
worldfires
CG · Congo - Brazzaville · →

Kimongo fire, 20 August 2026 Kimongo

Out · last detection 20 Aug 2026, 13:14 UTC

The fire started on 20 August 2026 in Kimongo, Congo - Brazzaville, and satellites saw it burning for 1 day. Copernicus’s global GWIS system rebuilt a burnt perimeter of 1,500 hectares from heat detections, spread across a single municipality.

It is the 66th largest in Bouenza since 2016 (of 180 with a page). Number 139 in Congo - Brazzaville in 2026, of 360.

Burnt area
1,500ha
GWIS perimeter (Copernicus)
Duration
1day
20 Aug 2026 – 20 Aug 2026
Municipalities hit
1
districts
Started on
20 Aug
2026
Heat detections
12
in a single hotspot: 47 MW
Danger at start
16
Moderate · FWI index
Energy released
232MW
sum of detected power

Where it burned

HOTSPOTS BY DAY 20 Aug20 Aug

How it evolved, day by day

20

Fire radiative power detected each day, in megawatts, and number of hotspots. The magenta bar marks the peak day.

The weather it burned in

30°high
17km/h · peak gust
56%lowest humidity

It had gone more than two months without rain (1 mm or more) when it started. Rain came after the fire: 2.7 mm on 28 Aug.

This area had burned before

No earlier perimeters overlap this fire since 2016, when the satellite record begins.

What happened to each town

  1. Kimongo where it started
    1,510 ha reached on 20 Aug
    0.8 %

Burnt area inside each municipality, from crossing the GWIS perimeter with administrative boundaries. The distance is from the town centre to the nearest fire: staying a kilometre away does not mean it reached the houses.

The weather day by day

ECMWF ERA5 reanalysis at the fire location, the standard reference for past weather, and the Canadian Fire Weather Index (the same system Copernicus uses), computed by WorldFires from that data. Days after the fire run until the first rain.

Open-Meteo.com (CC BY 4.0) · Copernicus Climate Change Service (ERA5)

Day High Min. humidity Peak gust Rain Danger (FWI)
20 Aug 30.0 °C 56 % 17 km/h 0.0 mm Moderate 16
21 Aug after 26.9 °C 69 % 23 km/h 0.1 mm Moderate 15
22 Aug after 29.1 °C 61 % 24 km/h 0.0 mm Moderate 14
23 Aug after 27.6 °C 64 % 31 km/h 0.0 mm Moderate 16
24 Aug after 24.7 °C 74 % 25 km/h 0.8 mm Low 9
25 Aug after 25.4 °C 73 % 22 km/h 0.3 mm Low 10
26 Aug after 31.9 °C 53 % 27 km/h 0.0 mm Moderate 17
27 Aug after 27.5 °C 67 % 22 km/h 0.0 mm Moderate 16
28 Aug after 22.9 °C 80 % 27 km/h 2.7 mm Very low 3

Before and after, from space

Drag the line to compare the same ground before the fire and after it.

Before · 13 Aug 2026
After · 27 Aug 2026

If the day is cloudy, change the date: each satellite passes once a day. In false colour the burnt ground looks brown or red.

The smoke

CAMS · Copernicus

On 19 August 2026 the air beside the fire reached 126 µg/m³ of PM2.5. That day averaged 88: 5.9 times the WHO daily guideline (15).

PM2.5 peak126 µg/m³
Days over the guideline6 days
PM10129 µg/m³
Optical depth3.12
181920212223
Good Fair Moderate Poor Very poor Extremely poor

Particles from the Copernicus CAMS model at the centre of the perimeter; these are not measurements in each town. The pale bar is the worst hour, the solid one the daily average.

Open-Meteo.com (CC BY 4.0) · Copernicus Atmosphere Monitoring Service (CAMS)

Detections table · 12Every satellite heat detection, one by one, with time, satellite, power and coordinates.
⬇ Download CSV Times in UTC. Each detection is a 375 m pixel: a large fire yields hundreds per pass.
Date and timeSatelliteFRP (MW)LatLon

Other fires nearby

All fires in Congo - Brazzaville ›

Frequently asked questions

How long did the Kimongo fire last?
GWIS (Copernicus) dates it between 20 August 2026 and 20 August 2026: 1 day between the first and last heat detection of the perimeter.
How much area did it burn?
The perimeter GWIS (Copernicus) rebuilt from heat detections is 1,500 hectares (15.0 km²). It is an estimate: official national figures may differ.
Which municipalities burned?
The fire only entered Kimongo (1,510 ha, 0.8 %).
What was the weather like?
During the fire the temperature reached 30.0 °C, humidity dropped to 56 % and gusts hit 17 km/h. The fire danger index (FWI) reached 16, class Moderate.
Where does this data come from?
From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Congo - Brazzaville (geoBoundaries). It is not an official report.

Where to verify it

A satellite detection is not an official report. Final figures and the fire’s status are published by each country’s emergency service.

Satellite cross-check

Does something look wrong on this page?

This page is built from satellite data and official records, and it sometimes gets things wrong: the wrong dates, the wrong town, two fires merged into one, or something that was not a wildfire at all. If you know this fire first-hand (you live nearby, saw it, fought it or reported on it), tell us what really happened and we will check it.

Report an error
What do you think is wrong?

We will only use your email to reply about this report. Privacy.

Where this data comes from

The perimeter comes from the Copernicus Global Wildfire Information System (GWIS), which rebuilds it from MODIS and VIIRS heat detections and publishes it under CC BY 4.0. It is not measured on imagery as in Europe, so it is an estimate. Heat detections come from the VIIRS sensors aboard Suomi-NPP and NOAA-20, distributed by NASA FIRMS at 375 m resolution. Municipal boundaries come from geoBoundaries ADM2 (Public Domain). The area per municipality is computed by WorldFires by crossing the perimeter with those boundaries, so it may differ from each country’s official figure.