# Pedro Juan Caballero fire, 8 August 2017

The fire started on 8 August 2017 in Pedro Juan Caballero, Paraguay, and satellites saw it burning for 4 days. Copernicus’s global GWIS system rebuilt a burnt perimeter of 2,077 hectares from heat detections, spread across a single municipality.

## Key facts

- Burned area: 2,077 ha · perimeter rebuilt from heat detections (Copernicus GWIS)
- Dates: 8 August 2017 – 11 August 2017 (4 days)
- Heat detections (VIIRS): 58
- Pedro Juan Caballero, Paraguay · -22.9785, -56.0121
- It burned the equivalent of 1.3% of the area of London (21 km² against 1,583 km²). London boundary: geoBoundaries · Office for National Statistics (Open Government Licence v3.0).
- Number 118 in Paraguay in 2017, of 261.
- It is number 48 by size of the 70 fires with a page that started in AMAMBAY since 2016.

## What happened to each town

| Municipality | Hectares | % of the municipality |
|---|---:|---:|
| Pedro Juan Caballero (where it started) | 2,089 | 0.4 |

## What burned

Land cover · ESA WorldCover 2021: Tree cover 63 %, Grassland 32 %, Cropland 4.2 % (© ESA WorldCover project 2021 / Contains modified Copernicus Sentinel data (2021) processed by ESA WorldCover consortium, CC BY 4.0)

Between 218 and 381 m, 314 m on average (at 200 random points inside the perimeter: the real extremes may reach a little further). (produced using Copernicus WorldDEM-90 © DLR e.V. 2010-2014 and © Airbus Defence and Space GmbH 2014-2018 provided under COPERNICUS by the European Union and ESA; all rights reserved. The organisations in charge of the Copernicus programme by law or by delegation do not incur any liability for any use of the Copernicus WorldDEM-90)


## People and buildings inside the perimeter

Inside the perimeter there were about 0.14 hectares of built-up land and almost nobody lived there (GHSL 2015, satellite-based estimate).

> This is an estimate on 100 m cells, made from satellite imagery and census data: it does not mean that homes burned or that anyone was harmed. The perimeter also contains land that never burned.

- Source: Global Human Settlement Layer (GHS-BUILT-S and GHS-POP R2023A), European Commission Joint Research Centre (JRC), © European Union, CC BY 4.0. Sum inside the perimeter computed by WorldFires. https://human-settlement.emergency.copernicus.eu/

## This area had burned before

- 2016: 57 ha

## Its twins: fires that started in the same weather

It started with an FWI of 33.5, a minimum humidity of 26% and 4 days without rain. Fires in the area that started in weather like this since 2016: 27.

- median duration: 5 days
- median area: 3,335 ha
- went past 10,000 ha: 4 %
- rain at the end (median; 20 of 27 had it): 4.2 mm

It stayed below its twins: 2,077 ha against a median of 3,335 ha. It lasted 4 days, against 5 days. In 7 of 27, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 4.2 mm.

- [Pedro Juan Caballero fire, September 2019](https://worldfires.org/en/fire/pedro-juan-caballero-2019-09-7) — 2,334 ha, FWI 31.2
- [San Carlos fire, August 2021](https://worldfires.org/en/fire/san-carlos-2021-08-2) — 1,748 ha, FWI 33.6
- [Pedro Juan Caballero fire, August 2021](https://worldfires.org/en/fire/pedro-juan-caballero-2021-08-7) — 1,659 ha, FWI 30.1
- [San Carlos fire, July 2021](https://worldfires.org/en/fire/san-carlos-2021-07-3) — 4,350 ha, FWI 32.7
- [Porto Murtinho fire, September 2021](https://worldfires.org/en/fire/porto-murtinho-2021-09-3) — 4,883 ha, FWI 32.2

## Frequently asked questions

### How long did the Pedro Juan Caballero fire last?

GWIS (Copernicus) dates it between 8 August 2017 and 11 August 2017: 4 days between the first and last heat detection of the perimeter.

### How much area did it burn?

The perimeter GWIS (Copernicus) rebuilt from heat detections is 2,077 hectares (20.8 km²). It is an estimate: official national figures may differ.

### Which municipalities burned?

The fire only entered Pedro Juan Caballero (2,089 ha, 0.4 %).

### What was the weather like?

During the fire the temperature reached 35.8 °C, humidity dropped to 21 % and gusts hit 61 km/h. The fire danger index (FWI) reached 49, class Very high.

### Where does this data come from?

From the GWIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Paraguay (geoBoundaries). It is not an official report.

### How did the fires that started in similar weather in this area end?

Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 27. Their median duration was 5 days and their median area 3,335 ha; 4 % went past 10,000 ha. In 7 of 27, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 4.2 mm.

## Other fires nearby

- [Pedro Juan Caballero, 4 September 2019](https://worldfires.org/en/fire/pedro-juan-caballero-2019-09-4.md) · 4,538 ha · 3 km
- [Pedro Juan Caballero, 14 August 2021](https://worldfires.org/en/fire/pedro-juan-caballero-2021-08.md) · 21,053 ha · 5 km
- [Yvy Ya´U, June 2024](https://worldfires.org/en/fire/yvy-ya-u-2024-06.md) · 5,051 ha · 22 km
- [Pedro Juan Caballero, 4 September 2024](https://worldfires.org/en/fire/pedro-juan-caballero-2024-09.md) · 7,645 ha · 24 km
- [Pedro Juan Caballero, 7 September 2019](https://worldfires.org/en/fire/pedro-juan-caballero-2019-09-8.md) · 8,021 ha · 27 km
- [Yvy Ya´U, 17 August 2021](https://worldfires.org/en/fire/yvy-ya-u-2021-08.md) · 14,912 ha · 31 km

## How we know this

- Perimeter: GWIS (Copernicus), rebuilt from heat detections rather than mapped on imagery.
- Dates from the perimeter: the VIIRS detections inside it did not change them. 58 Suomi-NPP VIIRS detections on those dates.
- We have not matched this page with any official record.
- Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.
- Built-up area and population come from the JRC Global Human Settlement Layer (epoch 2015, 100 m cells), summed inside the perimeter: an estimate of what was there, not a damage count.

[How we build fire pages: methodology](https://worldfires.org/en/methodology)

## What each figure measures

Area: that of the published perimeter (or the estimate from heat detections if there is none yet), not the country’s official figure. Rank in the country: among the fire pages of that year. Rank in the region: among the fire pages that started there since 2016. By municipality: the part of the perimeter inside each one.

## How to cite

WorldFires, “Pedro Juan Caballero fire, 8 August 2017”, https://worldfires.org/en/fire/pedro-juan-caballero-2017-08 (accessed 23 November 2026). Sources: GWIS / Copernicus (reconstructed from VIIRS) (CC BY 4.0), NASA FIRMS (VIIRS).

Citable version (24 October 2026): https://worldfires.org/en/fire/pedro-juan-caballero-2017-08?v=2026-10-24

> Open satellite data processed automatically: it may contain errors and is not an official emergency service. If there is a fire, call your local emergency number. Emergency number (Paraguay): 132 · 911.

Full version with maps: https://worldfires.org/en/fire/pedro-juan-caballero-2017-08
