# Giano Vetusto fire, August 2017

The fire started on 15 August 2017 in Giano Vetusto, Italy, and satellites saw it burning for 5 days. Copernicus mapped a burnt perimeter of 146 hectares from satellite imagery, spread across 4 municipalities.

## Key facts

- Burned area: 146 ha · perimeter measured by satellite (Copernicus EFFIS)
- Dates: 15 August 2017 – 19 August 2017 (5 days)
- Heat detections (VIIRS): 19
- Giano Vetusto, Italy · 41.2081, 14.2056
- Number 242 in Italy in 2017, of 361.
- It is number 32 by size of the 69 fires with a page that started in Caserta since 2016.

## What happened to each town

| Municipality | Hectares | % of the municipality |
|---|---:|---:|
| Giano Vetusto (where it started) | 117 | 10.7 |
| Formicola | 23 | 1.5 |
| Camigliano | 5 | 0.9 |
| Rocchetta e Croce | 1 | 0.0 |

## What burned

Land cover · ESA WorldCover 2021: Shrubland 44 %, Tree cover 42 %, Grassland 14 % (© ESA WorldCover project 2021 / Contains modified Copernicus Sentinel data (2021) processed by ESA WorldCover consortium, CC BY 4.0)

Between 312 and 700 m, 548 m on average (at 100 random points inside the perimeter: the real extremes may reach a little further). (produced using Copernicus WorldDEM-90 © DLR e.V. 2010-2014 and © Airbus Defence and Space GmbH 2014-2018 provided under COPERNICUS by the European Union and ESA; all rights reserved. The organisations in charge of the Copernicus programme by law or by delegation do not incur any liability for any use of the Copernicus WorldDEM-90)

Scrub and transitional woodland 53 %, Other natural land 34 %, Broadleaved forest 13 % — Land cover inside the perimeter according to Corine Land Cover, as reported by Copernicus.

Natura 2000 protected area affected: 100 %
- Catena di Monte Maggiore (IT8010006)


## The smoke

On 19 August 2017 the air beside the fire reached 43 µg/m³ of PM2.5. That day averaged 22: 1.5 times the WHO daily guideline (15).

- Days over the guideline: 2
- CAMS · Copernicus

## Its twins: fires that started in the same weather

It started with an FWI of 30.7, a minimum humidity of 32% and 19 days without rain. Fires in the area that started in weather like this since 2016: 20.

- median duration: 2 days
- median area: 176 ha
- went past 1,000 ha: 0 %
- rain at the end (median; 15 of 20 had it): 3.7 mm

It burned an area similar to its twins (146 ha against a median of 176 ha) and lasted 5 days, against 2 days. In 5 of 20, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 3.7 mm.

- [Formia fire, August 2021](https://worldfires.org/en/fire/formia-2021-08) — 763 ha, FWI 29.7
- [Sarno fire, July 2025](https://worldfires.org/en/fire/sarno-2025-07) — 254 ha, FWI 31.3
- [Sessa Aurunca fire, July 2022](https://worldfires.org/en/fire/sessa-aurunca-2022-07) — 106 ha, FWI 30.2
- [Arienzo fire, July 2017](https://worldfires.org/en/fire/arienzo-2017-07) — 192 ha, FWI 30.9
- [Santa Maria a Vico fire, August 2021](https://worldfires.org/en/fire/santa-maria-a-vico-2021-08) — 134 ha, FWI 32.4

## Frequently asked questions

### How long did the Giano Vetusto fire last?

According to the heat detections seen by satellite inside the perimeter, it burned from 15 August 2017 to 19 August 2017 (5 days). The perimeter dates it from 15 August 2017 to 16 August 2017.

### How much area did it burn?

The perimeter Copernicus measured from satellite imagery is 146 hectares (1.5 km²). Official national figures may differ.

### Which municipalities burned?

The fire entered 4 municipalities: Giano Vetusto (117 ha, 11 %); Formicola (23 ha, 1.5 %); Camigliano (5 ha, 0.9 %); Rocchetta e Croce (1 ha, 0.0 %).

### Did the fire reach a town?

The fire started in Giano Vetusto and came within 0.6 km of its centre. That is the distance from the perimeter, or the nearest hotspot, to the point marking the centre; it does not mean it entered the houses.

### What was the weather like?

During the fire the temperature reached 31.8 °C, humidity dropped to 30 % and gusts hit 36 km/h. The fire danger index (FWI) reached 37, class High.

### Where does this data come from?

From the EFFIS (Copernicus) burnt perimeter, NASA FIRMS VIIRS hotspots and the administrative boundaries of Italy (geoBoundaries). It is not an official report.

### How did the fires that started in similar weather in this area end?

Fires less than 250 km away that started since 2016 with a similar FWI, humidity and dry spell: 20. Their median duration was 2 days and their median area 176 ha; 0 % went past 1,000 ha. In 5 of 20, not even 1 mm fell in the ten days after the end: they went out without rain. In the rest, the first rainy day brought a median of 3.7 mm.

## Other fires nearby

- [Piana di Monte Verna, August 2024](https://worldfires.org/en/fire/piana-di-monte-verna-2024-08.md) · 542 ha · 9 km
- [Caserta, August 2021](https://worldfires.org/en/fire/caserta-2021-08.md) · 607 ha · 13 km
- [Casagiove, July 2017](https://worldfires.org/en/fire/casagiove-2017-07.md) · 496 ha · 14 km
- [Caserta, August 2017](https://worldfires.org/en/fire/caserta-2017-08.md) · 356 ha · 18 km
- [Valle di Maddaloni, July 2017](https://worldfires.org/en/fire/valle-di-maddaloni-2017-07.md) · 380 ha · 22 km
- [Mondragone, August 2022](https://worldfires.org/en/fire/mondragone-2022-08.md) · 350 ha · 26 km

## How we know this

- Perimeter: EFFIS (Copernicus), mapped on satellite imagery.
- Dates adjusted with the VIIRS detections inside the perimeter, which said 15 August 2017 to 16 August 2017. 19 Suomi-NPP VIIRS detections on those dates.
- We have not matched this page with any official record.
- Weather: Copernicus ERA5 reanalysis at the fire location, in cells of about 25 km.

[How we build fire pages: methodology](https://worldfires.org/en/methodology)

## What each figure measures

Area: that of the published perimeter (or the estimate from heat detections if there is none yet), not the country’s official figure. Rank in the country: among the fire pages of that year. Rank in the region: among the fire pages that started there since 2016. By municipality: the part of the perimeter inside each one.

## How to cite

WorldFires, “Giano Vetusto fire, August 2017”, https://worldfires.org/en/fire/giano-vetusto-2017-08 (accessed 25 November 2026). Sources: EFFIS / Copernicus EMS (CC BY 4.0), NASA FIRMS (VIIRS).

Citable version (24 October 2026): https://worldfires.org/en/fire/giano-vetusto-2017-08?v=2026-10-24

> Open satellite data processed automatically: it may contain errors and is not an official emergency service. If there is a fire, call your local emergency number. Emergency number (Italy): 112 · 1515.

Full version with maps: https://worldfires.org/en/fire/giano-vetusto-2017-08
